Whirlpool AKM 438/NB INSTRUCTION FOR USE

AKM 438 PRODUCT DESCRIPTION SHEET
DE FR NL BE
1. Removable panstand grids
2. Large burner 3-4. Medium burners
5. Small burner
6. Large burner control knob
7. Medium burner control knob
8. Medium burner control knob
9. Small burner control knob
Symbols
haded circle Tap closed
Large flame
nd star
mall flame
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
Operation of burners with electric ignition
To light one of the burners:
Press the relative knob and turn it anti-clockwise to the large flame and star setting .
At the same time, keep the knob pressed against the control panel until the burner ignites.
After the burner has ignited, keep the knob pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operation.
Note: — Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
5019 319 61411/A
The safety device of the burner shuts off the
gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc.).
Important
Improper use of the grids can result in damage to the hob: do not position the grids upside down or slide them across the hob.
Do not use:
cast iron griddles or terracotta pots and pans heat diffusers such as metal mesh, or any
other types
two burners simultaneously for one
receptacle (e.g. fish kettle).
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: If the distance “A“between the wall cabinets is between 600 mm and 680 mm,
the height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm. In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY I2L
Type of gas used
NATURAL GAS (Groningue) G 25
Type of gas used
G 25 25 mbar
Type of burner
large medium small
Injector marking
129
99 78
Appliance model
4 gas 7.30 809 l/h 14.6
Rated heat capacity Pcs-kW
3.00
1.65
1.00
Total rated heat capacity kW
Rated consumption
332 l/h 183 l/h 111 l/h
Reduced heat capacity Pcs-kW
0.60
0.35
0.35
Total rated consumption
min. rat. max.
Gas pressure
20 25 30
Air required for burning
3
m
/h
Loading...