Whirlpool AKM 436/NB, AKM 436/WH, AKM 436/MR INSTRUCTION FOR USE

AKM 436 PRODUCT DESCRIPTION SHEET
ES PT IT
1. Removable panstand grids
2. Large burner 3-4. Medium burners
5. Small burner
6. Large burner control knob
7. Medium burner control knob
8. Medium burner control knob
9. Small burner control knob
Symbols
Shaded circle Tap closed Large flame
and star
Small flame
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-clockwise to the large flame and star setting .
After the burner has ignited, keep the knob pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operation described above.
Note — Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
5019 319 61091/A
The safety device of the burner shuts off the
gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc.).
Important
Improper use of the grids can result in damage to the hob: do not position the grids upside down or slide them across the hob.
Do not use:
cast iron griddles or terracotta pots and pans heat diffusers such as metal mesh, or any
other types
two burners simultaneously for one
receptacle (e.g. fish kettle).
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: If the distance “A“ between the wall cabinets is between 600 mm and 680 mm,
the height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm. In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS (Methane) G 20
LIQUIFIED PETROLEUM GAS (Cylinder) G 30
LIQUIFIED PETROLEUM GAS (Cylinder) G 31
Type of gas used
G 20 20 mbar 4 gas 7.30 695 l/h 14.6 G 30 28-30 mbar 4 gas 7.30 531 g/h 14.6 G 31 37 mbar 4 gas 7.30 521 g/h 14.6
Type of burner
large medium small
large medium small
large medium small
Appliance model
Injector marking
128
94 76
85 65 50
85 65 50
Rated heat capacity Pcs-kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat capacity Pcs-kW
Rated consumption
286 l/h 157 l/h
95 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
Reduced heat capacity Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated consumption
Gas pressure
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for burning
3
m
/h