AKM 433 |
PRODUCT DESCRIPTION SHEET |
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
GB |
IE |
1. Removable panstand grids
2. Large burner
3-4. Medium burners
5. Auxiliary burner
6. Large burner control knob
7. Medium burner control knob
8. Medium burner control knob
9. Auxiliary burner control knob
10. Timer control knob
Symbols
Shaded circle |
Valve closed |
|
High flame |
Maximumaperture/supply |
|
and star |
and electric ignition |
|
Low flame |
Minimum |
|
aperture/supply |
||
|
Electrically ignited gas burner user instructions
How to ignite one of the burners:
•Push and turn the corresponding knob anti-
clockwise until the reference is aligned with the high flame and star symbols .
•At the same time, keep the knob pressed against the control panel until the burner ignites.
•At the same time hold the knob against the control panel until the burner ignites.
•Release the knob.
If the burner fails to ignite, repeat the sequence.
Note:
-If problems with local gas supply impede burner
ignition, repeat the sequence by turning the knob to the low flame symbol .
Using the timer
This particular model features a mechanical timer which can time up to one hour of cooking.
•Turn the knob clockwise until the reference is aligned with the desired cooking time.
•When the set time elapses an acoustic signal is activated.
Important
Improper use of the grids can result in damage to the hob: do not position the grids upside down or slide them across the hob.
Do not use:
—cast iron griddles or terracotta pots and pans
—heat diffusers such as metal mesh, or any other types
—two burners simultaneously for one receptacle (e.g. fish kettle).
5019 319 61251/A
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: |
If the distance “A“ between the wall cabinets is between 600 mm and 680 mm, |
|||||||||||||||
|
the height “B” must be a minimum of 520 mm. |
|
|
|
|
|
|
|||||||||
|
If the distance “A” between the wall cabinets is greater than the width of the |
|||||||||||||||
|
cooktop, the height “B” must be a minimum of 400 mm. |
|
|
|
|
|
|
|||||||||
|
In case of installation of a hood above the cooktop, please refer to the hood |
|||||||||||||||
|
instructions for the correct distance. |
|
|
|
|
|
|
|
|
|
|
|||||
INJECTORS TABLE |
|
|
|
|
|
|
|
|
|
|
CATEGORY II2H3+ |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type of gas |
|
|
Type of |
Injector |
|
Rated |
Rated |
|
Reduced |
|
|
Gas pressure |
|
|||
used |
|
|
burner |
marking |
|
heat |
consumption |
heat |
|
|
|
|
|
|
||
|
|
|
|
|
|
capacity |
|
|
|
capacity |
min. |
|
rat. |
|
max. |
|
|
|
|
|
|
|
Pcs-kW |
|
|
|
Pcs-kW |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
large |
128 |
|
3.00 |
286 l/h |
|
0.60 |
|
|
|
|
|
|
|||
medium |
94 |
|
1.65 |
157 l/h |
|
0.35 |
17 |
|
20 |
|
25 |
|||||
(Methane) |
G 20 |
|
|
|
|
|||||||||||
small |
76 |
|
1.00 |
95 l/h |
|
0.30 |
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUIFIED PETROLEUM |
large |
85 |
|
3.00 |
218 g/h |
|
0.60 |
|
|
|
|
|
|
|||
GAS |
|
|
medium |
65 |
|
1.65 |
120 g/h |
|
0.35 |
20 |
|
28-30 |
|
35 |
||
(Cylinder) |
G 30 |
small |
50 |
|
1.00 |
73 g/h |
|
0.30 |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUIFIED PETROLEUM |
large |
85 |
|
3.00 |
214 g/h |
|
0.60 |
|
|
|
|
|
|
|||
GAS |
|
|
medium |
65 |
|
1.65 |
118 g/h |
|
0.35 |
25 |
|
37 |
|
45 |
||
(Cylinder) |
G 31 |
small |
50 |
|
1.00 |
71 g/h |
|
0.30 |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
Type of gas |
|
Appliance |
|
Total rated heat |
|
Total rated |
|
|
Air required |
|
||||||
used |
|
|
model |
|
capacity |
|
|
consumption |
|
|
for burning |
|
||||
|
|
|
|
|
Pcs-kW |
|
|
|
|
|
|
m3/h |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
G 20 20 mbar |
|
4 gas |
|
7.30 |
|
|
695 l/h |
|
|
14.6 |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
G 30 28-30 mbar |
|
4 gas |
|
7.30 |
|
|
531 g/h |
|
|
14.6 |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
G 31 37 mbar |
|
4 gas |
|
7.30 |
|
|
521 g/h |
|
|
14.6 |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|