Whirlpool AKM 407/MR INSTRUCTION FOR USE

AKM 407

FR

PRODUCT DESCRIPTION SHEET

1. Removable panstand grids

2-3. Medium burners

4. Large burner

5. Medium burner 1.98 kw

6. Medium burner control knob

7. Medium burner control knob

8. Large burner control knob

9. Medium burner control knob

Symbols

Shaded

Tap closed

circle

 

Large

Maximum opening/flame delivery

flame

and electric ignition

and star

 

Small

Minimum opening

flame

or reduced delivery

Operation of burners with safety

 

- The safety device of the burner shuts off the gas

device and electric ignition

 

supply to the burner if its flame goes out

 

accidentally (because of a sudden gust of wind,

To light one of the burners:

 

 

an interruption in the gas delivery, the

Press the relative knob and turn it anti-clockwise

overflowing of liquids, etc.).

 

to the large flame and star setting

.

 

 

At the same time, keep the knob pressed against

Important

 

the control panel until the burner ignites.

 

Improper use of the grids can result in damage to

After the burner has ignited, keep the knob

 

the hob: do not position the grids upside down or

 

pressed for about 10 seconds.

 

slide them across the hob.

Release the knob.

 

Do not use:

 

 

 

If the burner does not ignite, repeat the operations

- cast iron griddles or terracotta pots and pans

described above.

- heat diffusers such as metal mesh, or any other

 

 

Note:

 

types

-

two burners simultaneously for one receptacle

-

Should particular local conditions of the delivered

 

 

gas make the ignition of the burner difficult, it is

(e.g.fish kettle).

 

advisable to repeat the operation with the knob

 

turned to the small flame setting .

 

 

 

5019 319 60381/A

 

Whirlpool is a registered trademark of Whirlpool USA

Whirlpool AKM 407/MR INSTRUCTION FOR USE

DIMENSIONS OF COOKING HOB AND WORKTOP (mm)

NOTES: In case of installation of a hood above the cooktop, please refer to the hood

instructions for the correct distance.

 

 

 

 

 

 

 

 

 

INJECTORS TABLE

 

 

 

 

 

 

 

 

 

CATEGORY II2E+3+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas

 

 

Type of

Injector

Rated heat

Rated

 

 

Reduced heat

 

Gas pressure (mbar)

used

 

 

burner

marking

capacity

consumption

 

capacity

 

 

 

 

 

 

 

 

min.

rat.

max.

 

 

 

 

 

 

kW

 

 

 

 

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

large

128

3.00

286 l/h

 

 

0.60

 

 

 

 

NATURAL GAS

 

 

medium

94

1.65

157 l/h

 

 

0.35

 

17

20

25

(Methane)

G20

 

medium

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(front right)

102

1.98

189 l/h

 

 

0.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

large

128

2.78

308 g/h

 

 

0.60

 

 

 

 

NATURAL GAS

 

 

medium

94

1.53

170 g/h

 

 

0.35

 

20

25

30

(Groningue)

G25

 

medium

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(front right)

102

1.84

204 g/h

 

 

0.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID

 

 

large

85

3.00

218 g/h

 

 

0.60

 

 

 

 

 

 

medium

65

1.65

120 g/h

 

 

0.35

 

 

 

 

PETROLEUM GAS

 

 

 

 

20

28-30

35

 

medium

 

 

 

 

 

 

 

 

(Cylinder)

G30

 

 

 

 

 

 

 

 

 

 

 

 

 

(front right)

70

1.98

144 g/h

 

 

0.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID

 

 

large

85

3.00

214 g/h

 

 

0.60

 

 

 

 

 

 

medium

65

1.65

118 g/h

 

 

0.35

 

 

 

 

PETROLEUM GAS

 

 

 

 

25

37

45

 

medium

 

 

 

 

 

 

 

 

(front right)

G31

 

 

 

 

 

 

 

 

 

 

 

 

 

(front right)

70

1.98

142 g/h

 

 

0.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas

 

 

 

Appliance

 

Total rated heat

 

Total rated

 

Air required

 

used

 

 

 

model

 

capacity

 

 

consumption

 

for burning

 

 

 

 

 

 

 

kW

 

 

 

 

 

 

m3/h

 

 

G20 20 mbar

 

 

 

4 gas

 

8.28

 

 

789 l/h

 

 

16.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G25 25 mbar

 

 

 

4 gas

 

7.68

 

 

852 l/h

 

 

15.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G30 28-30 mbar

 

4 gas

 

8.28

 

 

602 g/h

 

16.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G31 37 mbar

 

 

 

4 gas

 

8.28

 

 

592 g/h

 

16.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC SUPPLY: 230 V - 50 Hz