Whirlpool AKM 394/NA, AKM 394/JA, AKM 394/IR INSTRUCTION FOR USE

AKM 394 PRODUCT DESCRIPTION SHEET
FR
Removable panstand grids
1.
Medium burners
2-5.
Large burner
3.
Small burner
4.
Tr ip l e c ro wn bu rn er
6.
Small burner control knob
7.
Large burner control knob
8.
Triple crown burner control knob
9.
Medium burner control knob
10.
Medium burner control knob
11.
Symbols
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame and star setting .
At the same time, hold the knob down until the burner ignites.
After the burner has ignited, keep the knob pressed down for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Shaded circle
Large flame and star
Small flame
Note:
Should particular local conditions of the
delivered gas make ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting . The burner safety device shuts off the gas
supply to the burner if the flame goes out accidentally (because of a sudden draught, an interruption in the gas delivery, boiling over of liquids, etc.). The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm, must be sealed.
Tap closed
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
5019 319 01404
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 680 mm,
the height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm. Before installing a hood above the cooktop please refer to the hood instructions, which specify the correct distance. In case of installation of an oven under the cooktop, please refer to the separate oven instructions.
INJECTORS TABLE CATEGORY 112E+3+
Typ e o f gas used
NATURAL GAS (Methane) G20
LIQUID PETROLEUM GAS (Butane) G30
LIQUID PETROLEUM GAS (Propane) G31
Typ e of gas used
Typ e o f burner
Tr ip l e c ro w n large medium small
Tr ip l e c ro w n large medium small
Tr ip l e c ro w n large medium small
Appliance model
Injector marking
Rated heat capacity kW
3.30
132
3.00
Y 115
1.65
H2 98
1.00
X 72
3.30
92
3.00
87
1.65
65
1.00
50
3.30
92
3.00
87
1.65
65
1.00
50
Total rated heat capacity kW
Rated consumption
314 l/h 286 l/h 157 l/h
95 l/h
240 g/h 218 g/h 120 g/h
73 g/h
236 g/h 214 g/h 118 g/h
71 g/h
Total rated consumption
G20 20 mbar 3C-1R-2SR-1AUX 10.60 1009 l/h 9.52 G30 28-30 mbar 3C-1R-2SR-1AUX 10.60 771 g/h 30.94 G31 37 mbar 3C-1R-2SR-1AUX 10.60 757 g/h 23.80
ELECTRIC SUPPLY: 230 V ~ 50 Hz
: To replace the injectors, refer to the
NB “INSTALLATION”
section. In this product, the triple crown burner has only one injector
“INSTRUCTIONS FOR USE”
(D), therefore the instructions given in point 6 do not have to be followed..
Reduced heat capacity kW
1.50
0.60
0.35
0.30
1.50
0.60
0.35
0.30
1.50
0.60
0.35
0.30
handbook,
Gas pressure mbar
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required (m3) for burning 1m
3
of gas
Loading...