Whirlpool AKM 381/IX INSTRUCTION FOR USE

AKM 381 PRODUCT DESCRIPTION SHEET
FR
1. Removable panstand grids 2-5. Medium burners 3-6. Large burners
4. Small burner
7. Small burner control knob
8. Large burner control knob
9. Large burner control knob
10. Medium burner control knob
11. Medium burner control knob
Symbols
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame and star setting .
At the same time, keep the knob pressed against the control panel until the burner ignites.
After the burner has ignited, keep the knob pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Shaded circle
Large flame and star
Small flame
Tap closed
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
Note:
- Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
- The safety device of the burner shuts off the gas
supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc).
5019 319 61511
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: if the distance “A“ between the wall cabinets is between 660 mm and 680 mm, the
height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm. In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E3+
Type of gas used Type of
NATURAL GAS
(Methane) G 20 NATURAL
GAS (Groningue) G 25
LIQUID PETROLEUM GAS
(Cylinder) G 30 LIQUID
PETROLEUM GAS (Cylinder) G 31
Type of gas used Appliance model Total rated
G 20 20 mbar 5 gas 10.30 981 l/h 20.6 G 20 25 mbar 5 gas 9.55 1059 l/h 19.1 G 30 28-30 mbar 5 gas 10.30 749 g/h 20.6 G 31 37 mbar 5 gas 10.30 735 g/h 20.6
burner
large medium small
large medium small
large medium small
large medium small
Injector marking
128
94 76
128
94 76
85 65 50
85 65 50
Rated heat capacity Pcs-kW
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
heat capacity Pcs-kW
Rated consumption
286 l/h 157 l/h
95 l/h
308 l/h 170 l/h 103 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
Reduced heat capacity Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated consumption
Gas pressure
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Air required for burning
3
m
/h