Operation of burners with safety device and electric ignition

To light one of the burners:

Press the relative knob and turn it anti-

clockwise to the large flame and star setting .

At the same time, keep the knob pressed against the control panel until the burner ignites.

After the burner has ignited, keep the knob pressed for about 10 seconds.

Release the knob.

If the burner does not ignite, repeat the operations described above.

1.Removable panstand grids

2-5. Medium burners

3-6. Large burners

4.Small burner

7. Small burner control knob

8. Large burner control knob

9. Large burner control knob

10. Medium burner control knob

11. Medium burner control knob

Symbols

Shaded

Tap closed

circle

 

Large

Maximum opening/delivery

flame

and electric ignition

and star

 

Small

Minimum opening or

flame

reduced delivery

Note:

-Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation

with the knob turned to the small flame setting .

-The safety device of the burner shuts off the gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc).

5019 319 61511

Whirlpool AKM 381/IX INSTRUCTION FOR USE

DIMENSIONS OF COOKING HOB AND WORKTOP (mm)

NOTES: if the distance “A“ between the wall cabinets is between 660 mm and 680 mm, the height “B” must be a minimum of 520 mm.

If the distance “A” between the wall cabinets is greater than the width of the cooktop, the height “B” must be a minimum of 400 mm.

In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.

INJECTORS TABLE

 

 

 

 

 

 

 

 

 

CATEGORY II2E3+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas used

 

Type of

Injector

Rated heat

Rated

 

Reduced heat

 

Gas pressure

 

 

 

burner

marking

capacity

consumption

capacity

 

 

 

 

 

 

 

 

 

 

Pcs-kW

 

 

Pcs-kW

 

min.

rat.

max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL

 

 

large

128

3.00

286 l/h

 

0.60

 

 

 

 

GAS

 

 

medium

94

1.65

157 l/h

 

0.35

17

20

25

(Methane)

G 20

 

small

76

1.00

95 l/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL

 

 

large

128

2.78

308 l/h

 

0.60

 

 

 

 

GAS

 

 

medium

94

1.53

170 l/h

 

0.35

20

25

30

(Groningue)

G 25

 

small

76

0.93

103 l/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID

 

 

large

85

3.00

218 g/h

 

0.60

 

 

 

 

PETROLEUM GAS

 

medium

65

1.65

120 g/h

 

0.35

20

28-30

35

(Cylinder)

G 30

 

small

50

1.00

73 g/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID

 

 

large

85

3.00

214 g/h

 

0.60

 

 

 

 

PETROLEUM GAS

 

medium

65

1.65

118 g/h

 

0.35

25

37

45

(Cylinder)

G 31

 

small

50

1.00

71 g/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas used

 

Appliance model

 

Total rated

 

Total rated

 

Air required

 

 

 

 

 

 

 

 

heat capacity

consumption

 

for burning

 

 

 

 

 

 

 

 

Pcs-kW

 

 

 

 

m3/h

 

 

G 20 20 mbar

 

 

 

5 gas

 

 

10.30

 

981 l/h

 

20.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 20 25 mbar

 

 

 

5 gas

 

 

9.55

 

1059 l/h

 

19.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 30 28-30 mbar

 

5 gas

 

 

10.30

 

749 g/h

 

20.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 31 37 mbar

 

 

 

5 gas

 

 

10.30

 

735 g/h

 

20.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 