3gb61282.fm5 Page 1 Friday, September 14, 2001 10:41 AM
AKM 373
ES PT IT GB
PRODUCT DESCRIPTION SHEET
1. Removable panstand grids
2-5. Medium burners
3. Large burner
4. Small burner
6. Triple crown burner
7. Small burner control knob
8. Large burner control knob
9. Triple crown burner control knob
10. Medium burner control knob
11. Medium burner control knob
Symbols
Shaded
circle
Large
flame
and star
Small
flame
Tap closed
Maximum opening/delivery
and electric ignition
Minimum opening
or reduced delivery
Operation of burners with safety device
and electric ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame and star
setting .
• At the same time, hold the knob down until
the burner ignites.
• After the burner has ignited, keep the knob
pressed down for about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the operations
described above.
5019 319 61282
Note:
— Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
— The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden draught,
an interruption in the gas delivery, boiling
over of liquids, etc.).
— The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
3gb61282.fm5 Page 2 Friday, September 14, 2001 10:41 AM
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 680 mm, the
height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the
cooktop, the height “B” must be a minimum of 400 mm.
Before installing a hood above the cooktop please refer to the hood instructions,
which specify the correct distance. In case of installation of an oven under the
cooktop, please refer to the separate oven instructions.
INJECTORS TABLE CATEGORY II2H3+
Type of
gas used
NATURAL GAS
(Methane) G 20
LIQUID
PETROLEUM GAS
(Cylinder) G 30
LIQUID
PETROLEUM GAS
(Cylinder) G 31
Type of
gas used
Type of
burner
Triple crown
large
medium
small
Triple crown
large
medium
small
Triple crown
large
medium
small
Appliance
model
Injector
marking
121+59
128
94
76
86+37
85
65
50
86+37
85
65
50
Total rated heat
capacity
Pcs-kW
Rated heat
capacity
Pcs-kW
3.30
3.00
1.65
1.00
3.30
3.00
1.65
1.00
3.30
3.00
1.65
1.00
Rated
consumption
314 l/h
286 l/h
157 l/h
95 l/h
240 g/h
218 g/h
120 g/h
73 g/h
236 g/h
214 g/h
118 g/h
71 g/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
1.50
0.60
0.35
0.30
1.50
0.60
0.35
0.30
1.50
0.60
0.35
0.30
G 20 20 mbar 5 gas 10.6 1009 l/h 21.2
G 30 28-30 mbar 5 gas 10.6 771 g/h 21.2
G 31 37 mbar 5 gas 10.6 757 g/h 21.2
Gas pressure
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for
burning
3
m