Whirlpool AKM 371/JA/01, AKM 371/AR, AKM 371/NA/01, AKM 371/IX, AKM 371/JA PROGRAM CHART

AKM 371/01 PRODUCT DESCRIPTION SHEET
IT
1.
Removable panstand grids
2-5.
Medium burners
3-6.
Large burners
4.
Small burner
7.
Small burner control knob
8.
Large burner control knob
9.
Large burner control knob
10.
Medium burner control knob
11.
Medium burner control knob
Symbols
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-clockwise
to the large flame and star setting .
the control panel until the burner ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.  Release the knob. If the burner does not ignite, repeat the operations
described above.
5019 319 61871
Shaded circle
Large flame and star
Small flame
Tap closed
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
Note:
Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The safety device of the burner shuts off the gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc).
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: If the distance A between the wall cabinets is between 600 mm and 680 mm, the
height B must be a minimum of 520 mm. If the distance A between the wall cabinets is greater than the width of the cooktop, the height B must be a minimum of 400 mm. In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS (Methane) G 20
LIQUID PETROLEUM GAS
(Cylinder) G 30
LIQUID PETROLEUM GAS
(Cylinder) G 31
Type of gas used Appliance model Total rated heat
G 20 20 mbar 5 gas 10.30 981 l/h 20.6
G 30 28-30 mbar 5 gas 10.30 749 g/h 20.6
G 31 37 mbar 5 gas 10.30 735 g/h 20.6
Type of burner
large medium small
large medium small
large medium small
Injector marking
128
94 76
85 65 50
85 65 50
Rated heat capacity Pcs-kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
capacity Pcs-kW
Rated consumption
286 l/h 157 l/h
95 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
Reduced heat capacity Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated consumption
Gas pressure
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for
burning m
3