DESCRIPTION OF PRODUCT AND SYMBOLS

1.Removable grids

2.Semi-rapid burner

3.Rapid burner

4.Semi-rapid burner

5.

Auxiliary burner

6

2

3

4

5

7

6.

Rapid burner control knob

 

 

 

 

 

 

 

 

 

 

 

 

7.

Semi-rapid burner control knob

 

 

 

 

 

 

 

 

 

 

 

 

8.

Semi-rapid burner control knob

 

 

 

 

 

 

 

 

 

 

 

 

9.

Auxiliary burner control knob

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symbols

8

 

 

 

 

1

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

Cock closed

Max. flame

Min. flame

BURNER OPERATION

1.Turn the corresponding knob anticlockwise to the max. flame symbol.

2.Press the knob against the control panel to light the burner.

3.When the burner is lit, keep the knob pressed for about 5 seconds to allow the thermocouple (provided for each burner) to heat up.

This safety device shuts off the gas if the flame goes out accidentally (draughts, interruption of gas, liquids boiling over, etc.).

The device must not be operated for more than 15 sec. If the burner does not remain lit after this time, wait at least one minute before trying to light it again.

It may happen that the burner goes out when the knob is released. This means that the thermocouple has not heated up enough.

In this case, repeat the operations described above.

18

Whirlpool AKM 292/IX, AKM 291/IX INSTRUCTION FOR USE

PRACTICAL ADVICE FOR USING THE BURNERS

For maximum burner efficiency, comply with the following rules:

Use pots and pans of suitable size for each burner (see table opposite).

Only use flat-bottomed pots and pans.

Use the right amount of water for cooking foods and keep the lid on.

Do not use pots and pans that protrude over the edge of the hob

Do not use:

Two burners at the same time with only one pot (e.g. fish kettle).

Important:

Do not place and/or drag the grids upside down on the hob as they could scratch it.

Burner

Pot Ø

 

 

rapid

from 24 to 26 cm

semi-rapid

from 16 to 22 cm

auxiliary

8 to 14 cm

GRID POSITIONING

Position the grids as shown in the figure.

To avoid deterioration of the hob, it is provided with a raised grid for placing under pots wider than 26 cm.

19

DIMENSIONS AND DISTANCES TO BE

RESPECTED (mm)

If a hood is installed above the hob, refer to the hood instructions for the correct distance.

INJECTOR TABLE

INJECTOR TABLE

 

 

 

 

 

 

CATEGORY: II2H3+

IT + UK

 

 

 

 

Nominal

 

 

 

Reduced

Gas pressure

Type of gas used

Type of

Injector

heating

 

Nominal

heating

 

(mbar)

 

burner

marking

capacity

consumption

capacity

 

 

 

 

 

min.

nom.

max.

 

 

 

 

[kW]

 

 

 

[kW]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

rapid

128

 

3.00

 

286 l/h

 

0.90

 

 

 

 

 

(Methane) G20

semi-rapid

95

 

1.65

 

157 l/h

 

0.40

 

17

20

 

25

 

auxiliary

78

 

1.00

 

95 l/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUEFIED

rapid

85

 

3.00

 

218 g/h

 

0.90

 

 

 

 

 

PETROLEUM GAS

semi-rapid

65

 

1.65

 

120 g/h

 

0.40

 

25

30

 

35

(Butane) G30

auxiliary

50

 

1.00

 

73 g/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUEFIED

rapid

85

 

3.00

 

214 g/h

 

0.90

 

 

 

 

 

PETROLEUM GAS

semi-rapid

65

 

1.65

 

118 g/h

 

0.40

 

25

30

 

35

(Propane) G31

auxiliary

50

 

1.00

 

71 g/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

Nominal

 

Nominal total

 

Air necessary (m)

Type of gas used

 

heating

 

 

for combustion of

configuration

 

 

consumption

 

 

 

capacity kW

 

 

1 m3 of gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G20 20 mbar

4 burners

 

7.3

 

 

695 l/h

 

 

 

9.52

 

 

G30 30 mbar

4 burners

 

7.3

 

 

531 g/h

 

 

30.94

 

 

G31 30 mbar

4 burners

 

7.3

 

 

521 g/h

 

 

23.80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SUPPLY: 230 V ~ 50 Hz

20