AKM 272 PRODUCT DESCRIPTION SHEET
NL
1. Removable panstand grids
1. Removable panstand grids
2-3. Medium burners
2-3. Medium burners
4. Large burner
4. Large burner
5. Small burner
5. Small burner
Symbols
Symbols
Shaded
Shaded
circle
circle
Large
Large
flame
flame
Small
Small
flame
flame
Star
Tap closed
Tap closed
Maximum opening/delivery
Maximum opening/delivery
Minimum opening
Minimum opening
or reduced delivery
or reduced delivery
Electric ignition
push-button
The control knobs of the cooking hob burners
and the electric ignition push-button are on the
control panel of the oven.
Operation of burners
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame setting .
• At the same time, press the push-button with
a star .
The spark plug gives out a spark that causes
the burner to ignite.
If the burner does not ignite, press the
push-button again.
5019 319 61381
Note
- Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the operation,
with the knob turned to the small flame
setting .
DIMENSIONS OF COOKTOP AND WORKTOP
NOTES: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY I2L
Type of gas
used
NATURAL
GAS
(Methane) G 25
Type of gas
used
G 25 25 mbar 4 gas 7.80 863 l/h 15.6
Type of
burner
large
medium
small
Appliance
model
Injector
marking
129
108
78
Rated heat
capacity
Pcs-kW
3.00
1.90
1.00
Total rated heat
capacity
Pcs-kW
Rated
consumption
332 l/h
210 l/h
111 l/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
0.60
0.35
0.35
min. rat. max.
20 25 30
Air required
for burning
3
m
Gas pressure
/h