Whirlpool AKM 272/IX, AKM 272/WH, AKM 272/NB PROGRAM CHART

AKM 272

NL

PRODUCT DESCRIPTION SHEET

 

 

1.1. Removablepanstandgridsgrids

 

 

2-23-.3.Mediumburners

4.4. Largeburner

5.5. Smallburner

Symbols

Shaded

TapTapclosed

circle

LargeLarge

Maximumopenining/delivery

flameflame

SmallSmall

 

MinMinimumopenining

 

flameflame

 

ororreducedddelivery

 

Star

Electric ignition push-button

The control knobs of the cooking hob burners and the electric ignition push-button are on the control panel of the oven.

Operation of burners

To light one of the burners:

Press the relative knob and turn it anticlockwise to the large flame setting .

At the same time, press the push-button with

a star .

The spark plug gives out a spark that causes the burner to ignite.

If the burner does not ignite, press the push-button again.

Note

-Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation, with the knob turned to the small flame setting .

5019 319 61381

Whirlpool AKM 272/IX, AKM 272/WH, AKM 272/NB PROGRAM CHART

DIMENSIONS OF COOKTOP AND WORKTOP

NOTES: In case of installation of a hood above the cooktop, please refer to the hood

instructions for the correct distance.

 

 

 

 

 

 

 

 

 

 

 

INJECTORS TABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

CATEGORY I2L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas

 

Type of

Injector

 

Rated heat

Rated

 

Reduced

 

Gas pressure

 

used

 

burner

marking

 

capacity

consumption

 

heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

capacity

min.

 

rat.

 

max.

 

 

 

 

 

 

Pcs-kW

 

 

 

 

Pcs-kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL

 

large

129

 

3.00

 

332 l/h

 

0.60

 

 

 

 

 

 

GAS

 

medium

108

 

1.90

 

210 l/h

 

0.35

20

 

25

 

30

(Methane) G 25

 

small

78

 

1.00

 

111 l/h

 

0.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas

 

Appliance

 

Total rated heat

 

Total rated

 

Air required

 

used

 

model

 

capacity

 

 

consumption

 

for burning

 

 

 

 

 

 

Pcs-kW

 

 

 

 

 

 

m3/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 25 25 mbar

 

4 gas

 

7.80

 

 

863 l/h

 

 

15.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loading...