Whirlpool AKM 269/IX, AKM 269/WH, AKM 269/NB, AKM 269/BR INSTRUCTION FOR USE

 

AKM 269

PRODUCT DESCRIPTION SHEET

 

 

 

 

 

 

 

 

GB

IE

Operation of burners with safety device and electric ignition

To light one of the burners:

Press the relative knob and turn it anti-

clockwise to the large flame and star setting .

At the same time, keep the knob pressed against the control panel until the burners ignites.

After the burner has ignited, keep the knob pressed for about 10 seconds.

Release the knob.

If the burner does not ignite, repeat the operations described above.

1.Removable panstand grids

2-3. Medium burners

4.Large burner

5.Small burner

6. Medium burner control knob

7. Medium burner control knob

8. Large burner control knob

9. Small burner control knob

Symbols

Shaded

Tap closed

circle

Large flame

Maximum opening of gas

and star

and electric ignition

Small

Minimum opening of gas

flame

Note:

Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the

operation with the knob turned to the small flame setting .

The safety device of the burner shuts off the gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc.).

5019 319 54531

Whirlpool is a registered trademark of Whirlpool USA

Whirlpool AKM 269/IX, AKM 269/WH, AKM 269/NB, AKM 269/BR INSTRUCTION FOR USE

DIMENSIONS OF COOKING HOB AND WORKTOP (mm)

NOTE: In case of installation of a hood above the cooktop, please refer to the hood

instructions for the correct distance.

 

 

 

 

 

 

 

 

 

 

INJECTORS TABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

CATEGORY II2H3+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Injector

Rated

 

 

 

 

 

Reduced

 

Gas pressure mbar

 

 

 

Type of

 

heat

 

Rated

 

 

heat

 

 

 

 

 

Type of gas used

 

burner

 

marking

capacity

 

consumption

 

capacity

 

 

 

 

 

 

 

 

 

100/mm

 

 

min.

 

rat.

max.

 

 

 

 

 

kW

 

 

 

 

 

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

 

 

large

 

128

 

3.00

 

286 l/h

 

 

0.60

 

 

 

 

 

 

 

medium

 

94

 

1.65

 

157 l/h

 

 

0.35

17

 

20

25

(Methane)

G20

 

 

 

 

 

 

 

 

small

 

76

 

1.00

 

95 l/h

 

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID PETROLEUM

 

large

 

85

 

3.00

 

218 g/h

 

 

0.60

 

 

 

 

 

GAS

 

 

medium

 

65

 

1.65

 

120 g/h

 

 

0.35

20

 

28-30

35

(Cylinder)

G30

 

small

 

50

 

1.00

 

73 g/h

 

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID PETROLEUM

 

large

 

85

 

3.00

 

214 g/h

 

 

0.60

 

 

 

 

 

GAS

 

 

medium

 

65

 

1.65

 

118 g/h

 

 

0.35

25

 

37

45

(Cylinder)

G31

 

small

 

50

 

1.00

 

71 g/h

 

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appliance

 

 

Total rated heat

 

Total rated

 

Air required

 

Type of gas used

 

 

 

 

 

for burning

 

 

model

 

 

capacity kW

 

 

consumption

 

 

 

 

 

 

 

 

 

 

m3/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G20 20 mbar

 

 

4 gas

 

 

7.30

 

 

 

695 l/h

 

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G30 28-30 mbar

 

4 gas

 

 

7.30

 

 

 

531 g/h

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G31 37 mbar

 

 

4 gas

 

 

7.30

 

 

 

521 g/h

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC SUPPLY: 230 V - 50 Hz