AKM 264 |
PRODUCT DESCRIPTION SHEET |
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
FR |
Operation of burners with electronic ignition
To light one of the burners:
•Press the relative knob and turn it anti-
clockwise to the large flame and star setting .
•At the same time, keep the knob pressed against the control panel until the burner ignites.
•After the burner has ignited, keep the knob pressed for about 10 seconds.
•Release the knob.
If the burner does not ignite, repeat the operations described above.
1.Removable panstand grids
2.Medium burner
3.Rapid electric hotplate
4.Large burner
5.Small burner
6. Medium burner control knob
7. Large burner control knob
8. Small burner control knob
9. Electric hotplate control knob
10. Pilot lamp for electric hotplate
Symbols
Shaded
Tap closed
circle
Large flame
Maximum opening/
and star
delivery and electronic ignition
Small flame
Minimum opening or reduced delivery
Note:
—Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the
operation with the knob turned to the small flame setting .
—The safety device of the burner shuts off the gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption of the gas delivery, the overflowing of liquids, etc.)
Operation of the electric hotplate
•Set the knob to one of positions 1-6, which correspond to different temperatures.
•To switch off the hotplate, set the knob to position “0”.
5019 319 61891/A
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance. |
|
|
|
|
|
|
|
|
|
||||||
INJECTORS TABLE |
|
|
|
|
|
|
|
|
|
CATEGORY II2E+3+ |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Type of gas used |
Type of |
Injector |
|
Rated heat |
Rated |
Reduced |
|
Gas pressure |
|||||||
|
|
burner |
marking |
|
capacity |
consumption |
heat |
|
|
|
|
|
|||
|
|
|
|
|
|
Pcs-kW |
|
|
|
capacity |
min. |
rat. |
|
max. |
|
|
|
|
|
|
|
|
|
|
|
Pcs-kW |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
|
large |
128 |
|
3.00 |
|
286 l/h |
0.60 |
|
|
|
|
|
||
|
medium |
94 |
|
1.65 |
|
157 l/h |
0.35 |
17 |
20 |
|
25 |
||||
(Methane) |
G 20 |
|
|
|
|||||||||||
small |
76 |
|
1.00 |
|
95 l/h |
0.30 |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
|
large |
128 |
|
2.78 |
|
308 l/h |
0.60 |
|
|
|
|
|
||
|
medium |
94 |
|
1.53 |
|
170 l/h |
0.35 |
20 |
25 |
|
30 |
||||
(Groningue) |
G 25 |
|
|
|
|||||||||||
small |
76 |
|
0.93 |
|
103 l/h |
0.30 |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUID PETROLEUM |
large |
85 |
|
3.00 |
|
218 g/h |
0.60 |
|
|
|
|
|
|||
GAS |
|
medium |
65 |
|
1.65 |
|
120 g/h |
0.35 |
20 |
28-30 |
|
35 |
|||
(Cylinder) |
G 30 |
small |
50 |
|
1.00 |
|
73 g/h |
0.30 |
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUID PETROLEUM |
large |
85 |
|
3.00 |
|
214 g/h |
0.60 |
|
|
|
|
|
|||
GAS |
|
medium |
65 |
|
1.65 |
|
118 g/h |
0.35 |
25 |
37 |
|
45 |
|||
(Cylinder) |
G 31 |
small |
50 |
|
1.00 |
|
71 g/h |
0.30 |
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
||||||||
Type of gas used |
|
Appliance model |
Total rated heat |
|
Total rated |
|
Air required for |
||||||||
|
|
|
|
|
capacity Pcs-kW |
|
consumption |
|
burning m3/h |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
G 20 20 mbar |
|
|
3 gas + 1 E |
|
5.65 |
|
|
538 l/h |
|
|
11.3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
G 25 25 mbar |
|
|
3 gas + 1 E |
|
5.24 |
|
|
581 l/h |
|
|
10.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
G 25 28-30 mbar |
|
3 gas + 1 E |
|
5.65 |
|
|
411 g/h |
|
11.3 |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
G 31 37 mbar |
|
|
3 gas + 1 E |
|
5.65 |
|
|
403 g/h |
|
11.3 |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ELECTRIC HOTPLATE POWER: 1500 W.