Page

 

Technical data

2

 

Spare part list

3

 

Exploded view

4

 

Wiring diagram

5

This documentation is only intended for qualified technicians who are aware of the respec-

tive safety regulations.

 

Date: 08.03.2000

Subject to modification

Document-No.: 4812 715 15475

 

Whirlpool AKM 262/IX Service Manual

08.03.2000 / Page 2

AKM 262/IX

Whirlpool Europe

 

S E R V I C E

Doc. No: 4812 715 15475

8571 262 38000

Customer Service

 

 

 

 

 

Technical data

1. Medium burner

2. Medium burner

3. Large burner

4. Small burner

Voltage: 230 V

Frequency: 50 Hz

Type of gas

Type of

 

Injector

Rated heat

Rated

 

 

Reducedheat

Gas pressure

 

used

burner

 

marking

 

capacity

consumption

 

capacity

 

(mbar)

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

min.

 

rat.

max.

Natural Gas

large

 

128

3.00

286 l/h

 

 

0.60

 

 

 

 

 

(Methane)

medium

 

94

1.65

157 l/h

 

 

0.35

 

17

 

20

25

G20

 

small

 

76

1.00

95 l/h

 

 

0.30

 

 

 

 

 

LPG

 

large

 

85

3.00

218 g/h

 

 

0.60

 

 

 

 

 

(Cylinder)

medium

 

65

1.65

120 g/h

 

 

0.35

 

20

 

28-30

35

G30

 

small

 

50

1.00

73 g/h

 

 

0.30

 

 

 

 

 

LPG

 

large

 

85

3.00

214 g/h

 

 

0.60

 

 

 

 

 

(Cylinder)

medium

 

65

1.65

118 g/h

 

 

0.35

 

25

 

37

45

G31

 

small

 

50

1.00

71 g/h

 

 

0.30

 

 

 

 

 

City Gas

large

 

270

3.00

680 l/h

 

 

0.60

 

 

 

 

 

G110

medium

 

185

1.65

374 l/h

 

 

0.35

 

6

 

8

15

 

 

small

 

145

1.00

227 l/h

 

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas used

 

Appliance

 

Total rated heat

 

Total rated

 

Air required for

 

 

 

 

model

 

capacity

 

consumption

 

burning (m3 /h)

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

G20

20 mbar

 

 

 

4 gas

 

7.30

 

 

 

 

695 l/h

 

 

14.6

 

G30

28-30 mbar

 

 

 

4 gas

 

7.30

 

 

 

531 g/h

 

 

14.6

 

G31

37 mbar

 

 

 

4 gas

 

7.30

 

 

 

521 g/h

 

 

14.6

 

G110 8 mbar

 

 

 

4 gas

 

7.30

 

 

 

1655 l/h

 

 

14.6

 

Loading...