Whirlpool AKM 260/WH, AKM 260/IX, AKM 260/AE/01, AKM 260/TF, AKM 260/JA PROGRAM CHART

...
AKM 260-262 PRODUCT DESCRIPTION SHEET
IT PT
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
Symbols
Shaded circle Tap closed
Large flame Maximum opening and star delivery and electric
ignition
Small flame Minimum opening or
reduced delivery
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star setting .
At the same time, keep the knob pressed
against the control panel until the burners ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.  Release the knob. If the burner does not ignite, repeat the operations described above.
5019 319 60061/A
Note:
Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The safety device of the burner shuts off the gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc.).
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS (Methane) G 20
LIQUID PETROLEUM GAS
(Cylinder) G 30
LIQUID PETROLEUM GAS
(Cylinder) G 31
Type of gas used
G 20 20 mbar 4 gas 7.30 695 l/h 14.6
G 25 28-30 mbar 4 gas 7.30 531 g/h 14.6
G 31 37 mbar 4 gas 7.30 521 g/h 14.6
Type of burner
large medium small
large medium small
large medium small
Appliance model
Injector marking
128
94 76
85 65 50
85 65 50
Rated heat capacity Pcs-kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat capacity Pcs-kW
Rated consumption
218 g/h 120 g/h
214 g/h 118 g/h
286 l/h 157 l/h
95 l/h
73 g/h
71 g/h
Reduced heat capacity Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated consumption
Gas pressure
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for burning
3
m
/h