Whirlpool AKM 260/NA/01, AKM 260 BR, AKM 260 INSTRUCTION FOR USE

AKM 260-260/01-262 PRODUCT DESCRIPTION SHEET
IT PT
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
Symbols
Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
setting .
At the same time, keep the knob pressed
against the control panel until the burners
ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations
described above.
5019 319 60062
Shaded
circle
Large
flame and
star
Small
flame
Tap closed
Maximum opening/delivery
and electric ignition
Minimum opening or
reduced delivery
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
The safety device of the burner shuts off the
gas supply to the burner if its flame goes out
accidentally (because of a sudden gust of
wind, an interruption in the gas delivery, the
overflowing of liquids, etc.).
Whirlpool is a registered trademark of Whirlpool USA
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS
(Methane) G20
LIQUID PETROLEUM
GAS
(Cylinder) G30
LIQUID PETROLEUM
GAS
(Cylinder) G31
Type of gas used
G20 20 mbar 4 gas 7.30 695 l/h 14.6
G30 28-30 mbar 4 gas 7.30 531 g/h 14.6
G31 37 mbar 4 gas 7.30 521 g/h 14.6
Type of
burner
large
medium
small
large
medium
small
large
medium
small
Appliance
model
Injector
marking
128
94
76
85
65
50
85
65
50
Rated
heat
capacity
kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat
capacity kW
Rated
consumption
218 g/h
120 g/h
214 g/h
118 g/h
286 l/h
157 l/h
95 l/h
73 g/h
71 g/h
Reduced
heat
capacity
kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated
consumption
min. rat. max.
17 20 25
20 28-30 35
25 37 45
ELECTRIC SUPPLY: 230V - 50Hz
Gas pressure mbar
Air required
for burning
3
m
/h
Loading...