AKM 220 |
FR |
PRODUCT DESCRIPTION SHEET |
Operation of burners with safety device and electric ignition
To light one of the burners:
•Press the relative knob and turn it anti-clockwise to the large flame and star setting .
•At the same time, keep the knob pressed against the control panel until the burner ignites.
•After the burner has ignited, keep the knob pressed for about 10 seconds.
•Release the knob.
If the burner does not ignite, repeat the operations described above.
1.Removable panstand grids
2-3. Medium burners
3.Large burners
4.Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
Symbols
Shaded |
Tap closed |
|
circle |
||
|
||
Large |
Maximum opening/flame delivery |
|
flame |
||
and electric ignition |
||
and star |
||
|
||
Small |
Minimum opening |
|
flame |
or reduced delivery |
Note:
-Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is
advisable to repeat the operation with the knob turned to the small flame setting .
-The safety device of the burner shuts off the gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc.).
5019 319 60401
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance. |
|
|
|
|
|
|
|
|
|
|
|||||||
INJECTORS TABLE |
|
|
|
|
|
|
|
|
|
|
|
CATEGORY II2H3+ |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Type of gas |
|
|
Type of |
Injector |
Rated heat |
Rated |
|
Reduced |
|
Gas pressure |
|||||||
used |
|
|
burner |
marking |
capacity |
consumption |
|
heat |
|
|
|
|
|
||||
|
|
|
|
|
|
|
Pcs-kW |
|
|
|
|
capacity |
min. |
|
rat. |
max. |
|
|
|
|
|
|
|
|
|
|
|
|
|
Pcs-kW |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
|
|
large |
128 |
|
3.00 |
|
286 l/h |
|
0.60 |
|
|
|
|
|
||
|
|
medium |
94 |
|
1.65 |
|
157 l/h |
|
0.35 |
17 |
|
20 |
25 |
||||
(Methane) |
G 20 |
|
|
|
|
|
|||||||||||
|
small |
76 |
|
1.00 |
|
95 l/h |
|
0.30 |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
|
|
large |
128 |
|
2.78 |
308 g/h |
|
0.60 |
|
|
|
|
|
|||
|
|
medium |
94 |
|
1.53 |
170 g/h |
|
0.35 |
20 |
|
25 |
30 |
|||||
(Groningue) |
G 25 |
|
|
|
|
||||||||||||
|
small |
76 |
|
0.93 |
|
73 g/h |
|
0.30 |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUIFIED |
|
|
large |
85 |
|
3.00 |
218 g/h |
|
0.60 |
|
|
|
|
|
|||
PETROLEUM GAS |
|
medium |
65 |
|
1.65 |
120 g/h |
|
0.35 |
20 |
|
28-30 |
35 |
|||||
(Cylinder) |
G 30 |
|
small |
50 |
|
1.00 |
|
73 g/h |
|
0.30 |
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUIFIED |
|
|
large |
85 |
|
3.00 |
214 g/h |
|
0.60 |
|
|
|
|
|
|||
PETROLEUM GAS |
|
medium |
65 |
|
1.65 |
118 g/h |
|
0.35 |
25 |
|
37 |
45 |
|||||
(Cylinder) |
G 31 |
|
small |
50 |
|
1.00 |
|
71 g/h |
|
0.30 |
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Type of gas |
|
|
|
Appliance |
|
|
Total rated heat |
|
Total rated |
|
Air required |
|
|||||
used |
|
|
|
model |
|
|
capacity |
|
|
consumption |
|
for burning |
|
||||
|
|
|
|
|
|
|
Pcs-kW |
|
|
|
|
|
|
m3/h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
G 20 20 mbar |
|
|
|
4 gas |
|
|
7.30 |
|
|
695 l/h |
|
|
14.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
G 25 25 mbar |
|
|
|
4 gas |
|
|
6.77 |
|
|
751 l/h |
|
|
13.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
G 30 28-30 mbar |
|
4 gas |
|
|
7.30 |
|
|
531 g/h |
|
|
14.6 |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
G 31 37 mbar |
|
|
|
4 gas |
|
|
7.30 |
|
|
521 g/h |
|
|
14.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|