Operation of burners with electric ignition

To light one of the burners:

Press the relative knob and turn it anticlockwise to the large flame setting .

At the same time, press the button with

the star .

The spark plug gives out a spark that causes the burner to ignite.

If the burner does not ignite, repeat the operations described above.

1.Removable panstand grids

2-3. Medium burners

4.Large burner

5.Small burner

6. Medium burner control knob

7. Medium burner control knob

8. Large burner control knob

9. Small burner control knob

10. Electric ignition button

Symbols

Shaded

Tap closed

circle

 

Large

Maximum opening/delivery

flame

 

Small

Minimum opening

flame

or reduced delivery

Note

-Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation

with the knob turned to the small flame setting .

5019 319 61931

Whirlpool AKM 218/NA, AKM 218/IX, AKM 218/NA/01 PROGRAM CHART

DIMENSIONS OF COOKING HOB AND WORKTOP

NOTES: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.

INJECTORS TABLE

 

 

 

 

 

 

 

 

 

 

CATEGORY I2L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas

 

 

Type of

Injector

 

Rated heat

Rated

 

Reduced heat

 

Gas pressure

used

 

 

burner

marking

 

capacity

consumption

capacity

 

 

 

 

 

 

 

 

min.

 

rat.

max.

 

 

 

 

 

 

 

Pcs-kW

 

 

Pcs-kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

 

 

large

129

3.00

332 l/h

 

0.60

 

 

 

 

 

 

 

medium

108

1.90

210 l/h

 

0.35

20

 

25

30

(Methane)

G 25

 

 

 

 

small

78

1.00

111 l/h

 

0.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas

 

 

 

Appliance

 

Total rated heat

Total rated

 

Air required

 

used

 

 

 

model

 

 

capacity

 

consumption

 

for burning

 

 

 

 

 

 

 

 

Pcs-kW

 

 

 

 

m3/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 25 25 mbar

 

 

 

4 gas

 

 

7.80

 

863 l/h

 

15.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 