Whirlpool AKM 215/IX INSTRUCTION FOR USE

 

AKM 215

PRODUCT DESCRIPTION SHEET

 

 

 

 

 

 

 

 

NL

Operation of burners with electric ignition

To light one of the burners:

Press the relative knob and turn it anti-clockwise to the large flame setting .

At the same time, press the button with the star .

The spark plug gives out a spark that causes the burner to ignite.

If the burner does not ignite, repeat the operations described above.

1.Removable panstand grids

2-3. Medium burners

4.Large burner

5.Small burner

6.Medium burner control

knob

7.Medium burner control

knob

8.Large burner control

knob

9.Small burner control

knob

10. Electric ignition button

Symbols

Shaded circle

Tap closed

Large

Maximum opening/

flame

delivery

Small

Minimum opening or

flame

reduced delivery

Note:

Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation

with the knob turned to the small flame setting .

5019 319 61421

Whirlpool AKM 215/IX INSTRUCTION FOR USE

DIMENSIONS OF COOKING HOB AND WORKTOP

NOTE:

In case of installation of a hood above the cooktop, please refer to the hood instructions

 

for the correct distance.

 

 

 

 

 

 

 

 

 

 

 

INJECTORS TABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

CATEGORY I2L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas used

 

Type of

 

Injector

Rated

 

Rated

 

Reduced

 

 

Gas pressure

 

 

 

burner

 

marking

heat

 

consumption

heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

capacity

 

 

 

 

capacity

min.

 

rat.

max.

 

 

 

 

 

 

 

Pcs-kW

 

 

 

 

Pcs-kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

 

large

 

129

 

3.00

 

332 l/h

 

0.60

 

 

 

 

 

 

medium

 

108

 

1.90

 

210 l/h

 

0.35

20

 

25

30

(Groningue) G 25

 

 

 

 

 

 

 

small

 

78

 

1.00

 

111 l/h

 

0.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas used

 

Appliance

 

 

Total rated heat

 

Total rated

 

Air required

 

 

 

 

model

 

 

capacity kW

 

 

consumption

 

for burning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

m3/h

 

G 25 25 mbar

 

4 gas

 

 

7.80

 

 

 

863 l/h

 

15.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 