Whirlpool AKM 214/WH/01, AKM 214/WH, AKM 214/NA/01, AKM 214/AR, AKM 214/NA INSTRUCTION FOR USE

...

 

AKM 214

PRODUCT DESCRIPTION SHEET

 

 

 

 

 

 

 

 

FR

1. Removable panstand grids

2. Medium burner

3. Rapid electric hotplate

4. Large burner

5. Small burner

6. Medium burner control knob

7. Large burner control knob

8. Small burner control knob

9. Electric hotplate control knob

10. Pilot lamp for electric hotplate

Symbols

Shaded

Tap closed

circle

Large flame and

Maximum opening/delivery

star

and electronic ignition

Small flame

Minimum opening or reduced delivery

Operation of burners with electronic ignition

To light one of the burners:

Press the relative knob and turn it anti-

clockwise to the large flame and star setting .

At the same time, keep the knob pressed against the control panel until the burner ignities.

Release the knob.

If the burner does not ignite, repeat the operations described above.

Operation of the electric hotplate

Set the knob to one of positions 1-6, which correspond to different temperatures.

To switch off the hotplate, set the knob to position “0”.

Note:

Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the

operation with the knob turned to the small flame setting .

5019 319 61111

Whirlpool AKM 214/WH/01, AKM 214/WH, AKM 214/NA/01, AKM 214/AR, AKM 214/NA INSTRUCTION FOR USE

DIMENSIONS OF COOKING HOB AND WORKTOP

NOTE: In case of installation of a hood above the cooktop, please refer to the hood

instructions for the correct distance.

 

 

 

 

 

 

 

 

INJECTORS TABLE

 

 

 

 

 

 

 

 

 

CATEGORY II2E+3+

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas used

Type of

Injector

 

Rated heat

Rated

 

Reduced

 

Gas pressure

 

 

burner

marking

 

capacity

consumption

heat capacity

 

 

 

 

 

 

 

 

 

 

 

Pcs-kW

 

 

Pcs-kW

min.

 

rat.

max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL

 

large

128

 

3.00

286 l/h

 

0.60

 

 

 

 

 

GAS

 

medium

94

 

1.65

157 l/h

 

0.35

17

 

20

25

(Methane)

G 20

small

76

 

1.00

95 l/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL

 

large

128

 

2.78

308 l/h

 

0.60

 

 

 

 

 

GAS

 

medium

94

 

1.53

170 l/h

 

0.35

20

 

25

30

(Methane)

G 25

small

76

 

0.93

103 l/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID PETROLEUM

large

85

 

3.00

218 g/h

 

0.60

 

 

 

 

 

GAS

 

medium

65

 

1.65

120 g/h

 

0.35

20

 

28-30

35

(Cylinder)

G 30

small

50

 

1.00

73 g/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID PETROLEUM

large

85

 

3.00

214 g/h

 

0.60

 

 

 

 

 

GAS

 

medium

65

 

1.65

118 g/h

 

0.35

25

 

37

45

(Cylinder)

G 31

small

50

 

1.00

71 g/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas used

 

Appliance model

Total rated

 

Total rated

 

Air required

 

 

 

 

 

 

heat capacity

consumption

 

for burning

 

 

 

 

 

 

Pcs-kW

 

 

 

 

m3/h

 

 

G 20 20 mbar

 

 

3 gas + 1 E

 

5.65

 

538 l/h

 

11.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 25 25 mbar

 

 

3 gas + 1 E

 

5.24

 

581 l/h

 

10.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 30 28-30 mbar

 

 

3 gas + 1 E

 

5.65

 

411 g/h

 

11.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 31 37 mbar

 

 

3 gas + 1 E

 

5.65

 

403 g/h

 

11.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC HOTPLATE POWER: 1500 W.

Loading...