Whirlpool AKM 212/NA, AKM 212/GR, AKM 212/WH INSTRUCTION FOR USE

AKM 212

FR

PRODUCT DESCRIPTION SHEET

Operation of burners with electronic ignition

To light one of the burners:

Press the relative knob and turn it anti-clockwise to the large flame and star setting .

At the same time, keep the knob pressed against the control panel until the burner ignites.

Release the knob.

If the burner does not ignite, repeat the operations described above.

1.Removable panstand grids

2-3. Medium burners

4.Large burner

5.Small burner 1.98 kw

6. Medium burner control knob

7. Medium burner control knob

8. Large burner control knob

9. Small burner control knob

Symbols

Shaded

Tap closed

circle

 

Large

Maximum opening/flame delivery

flame

and electric ignition

and star

 

Small

Minimum opening or reduced

flame

delivery

Note:

-Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is

advisable to repeat the operation with the knob turned to the small flame setting .

5019 319 60341

Whirlpool AKM 212/NA, AKM 212/GR, AKM 212/WH INSTRUCTION FOR USE

DIMENSIONS OF COOKING HOB AND WORKTOP

NOTES: In case of installation of a hood above the cooktop, please refer to the hood

instructions for the correct distance.

 

 

 

 

 

 

 

 

 

 

INJECTORS TABLE

 

 

 

 

 

 

 

 

 

 

CATEGORY II2E+3+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas used

 

Type of

Injector

Rated heat

Rated

 

Reduced

 

Gas pressure

 

 

 

burner

marking

capacity

consumption

 

heat

 

 

 

 

 

 

 

 

 

 

 

 

Pcs-kW

 

 

 

 

capacity

min.

rat.

 

max.

 

 

 

 

 

 

 

 

 

 

 

 

Pcs-kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

 

 

large

128

 

3.00

286 l/h

 

0.60

 

 

 

 

 

 

 

medium

94

 

1.65

157 l/h

 

0.35

17

20

 

25

(Methane)

G 20

 

 

 

 

 

small

76

 

1.00

 

95 l/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

 

 

large

128

 

2.78

308 l/h

 

0.60

 

 

 

 

 

 

 

medium

94

 

1.53

170 l/h

 

0.35

20

25

 

30

(Groningue)

G 25

 

 

 

 

 

small

76

 

0.93

103 l/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID

 

 

large

85

 

3.00

218 l/h

 

0.60

 

 

 

 

 

PETROLEUM GAS

 

medium

65

 

1.65

120 l/h

 

0.35

20

28-30

 

35

(Cylinder)

G 30

 

small

50

 

1.00

 

73l/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIQUID

 

 

large

85

 

3.00

214 l/h

 

0.60

 

 

 

 

 

PETROLEUM GAS

 

medium

65

 

1.65

118 l/h

 

0.35

25

37

 

45

(Cylinder)

G 31

 

small

50

 

1.00

 

71l/h

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of gas used

 

Appliance model

 

Total rated heat

 

Total rated

 

Air required for

 

 

 

 

 

 

 

capacity Pcs-kW

 

consumption

 

burning m3/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 20 20 mbar

 

 

 

4 gas

 

 

7.30

 

 

695 l/h

 

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 25 25 mbar

 

 

 

4 gas

 

 

6.77

 

 

751 l/h

 

 

13.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 30 28-30 mbar

 

4 gas

 

 

7.30

 

 

531 l/h

 

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 31 37 mbar

 

 

 

4 gas

 

 

7.30

 

 

521 l/h

 

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loading...