SERVICE
Model AKG 907/NB/WP
Version 8535 907 38040 Page
Whirlpool Europe
Customer Services
AKG 907/NB/WP
Service Manual
Hob
AKG 907/NB/WP
Technical data 2
Spare part list 3
Exploded view 4 - 5
Wiring diagram 6
This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 06.11.1997 (Mod.01) Subject to modification
Document-No.: 4812 715 17099
20.10.1997 / Page 2 AKG 907/NB/WP Whirlpool Europe
Doc. No: 4812 715 17099 8535 907 38040 Customer Service
Technical data
Electrical connection
Voltage 220 V
Frequency 50 Hz
Dimensions
Height 95 mm
Width 915 mm
Depth 553 mm
Build-in dimensions
Height 77 mm
Width 825 mm
Depth 467 mm
SERVICE
Type of gas used Type of
burner
City Gas
G 110
Natural Gas
(Methane)
G 20
Natural Gas
(Cylinder)
G 30 / G31
large
medium
large
medium
large
medium
Injector
marking
[mm]
3,40
2,00
1,45
1,05
0,90
0,71
Rated heat
capacity
PCS-kW
3,00
1,70
3,00
1,70
3,00
1,70
Rated
consumption
683 l/h
387 l/h
285 l/h
167 l/h
228 g/h
133 g/h
Gas pressure [mbar]
min. rat. max.
6815
15 18 23
(G30)
25
(G31)
25
30
30
35
35