S E R V I C E |
Whirlpool Europe |
Customer Services |
AKG 907/NB/WP
Service Manual
Hob
AKG 907/NB/WP
Model |
AKG 907/NB/WP |
|
Version |
8535 907 38040 |
Page |
|
Technical data |
2 |
|
Spare part list |
3 |
|
Exploded view |
4 - 5 |
|
Wiring diagram |
6 |
This documentation is only intended for qualified technicians who are aware of the respec-
tive safety regulations. |
|
Date: 06.11.1997 (Mod.01) |
Subject to modification |
Document-No.: 4812 715 17099 |
|
20.10.1997 / Page 2 |
AKG 907/NB/WP |
Whirlpool Europe |
|
S E R V I C E |
Doc. No: 4812 715 17099 |
8535 907 38040 |
Customer Service |
||
Technical data |
|
|
|
|
Electrical connection |
|
|
|
|
Voltage |
|
220 |
|
V |
Frequency |
|
50 |
|
Hz |
Dimensions |
|
|
|
|
Height |
|
95 |
|
mm |
Width |
|
915 |
|
mm |
Depth |
|
553 |
|
mm |
Build-in dimensions |
|
|
|
|
Height |
|
77 |
|
mm |
Width |
|
825 |
|
mm |
Depth |
|
467 |
|
mm |
Type of gas used |
Type of |
Injector |
Rated heat |
Rated |
Gas pressure [mbar] |
||
|
burner |
marking |
capacity |
consumption |
|
|
|
|
|
[mm] |
PCS-kW |
|
|
|
|
|
|
|
|
|
min. |
rat. |
max. |
City Gas |
large |
3,40 |
3,00 |
683 l/h |
6 |
8 |
15 |
G 110 |
medium |
2,00 |
1,70 |
387 l/h |
|
|
|
|
|
|
|
|
|
|
|
Natural Gas |
large |
1,45 |
3,00 |
285 l/h |
15 |
18 |
23 |
(Methane) |
medium |
1,05 |
1,70 |
167 l/h |
|
|
|
G 20 |
|
|
|
|
|
|
|
|
|
|
|
|
(G30) |
|
|
Natural Gas |
large |
0,90 |
3,00 |
228 g/h |
25 |
30 |
35 |
(Cylinder) |
medium |
0,71 |
1,70 |
133 g/h |
(G31) |
|
|
G 30 / G31 |
|
|
|
|
25 |
30 |
35 |