Whirlpool AKG 907/NB/WP Service Manual

0 (0)
Whirlpool AKG 907/NB/WP Service Manual

S E R V I C E

Whirlpool Europe

Customer Services

AKG 907/NB/WP

Service Manual

Hob

AKG 907/NB/WP

Model

AKG 907/NB/WP

 

Version

8535 907 38040

Page

 

Technical data

2

 

Spare part list

3

 

Exploded view

4 - 5

 

Wiring diagram

6

This documentation is only intended for qualified technicians who are aware of the respec-

tive safety regulations.

 

Date: 06.11.1997 (Mod.01)

Subject to modification

Document-No.: 4812 715 17099

 

20.10.1997 / Page 2

AKG 907/NB/WP

Whirlpool Europe

 

S E R V I C E

Doc. No: 4812 715 17099

8535 907 38040

Customer Service

Technical data

 

 

 

 

Electrical connection

 

 

 

 

Voltage

 

220

 

V

Frequency

 

50

 

Hz

Dimensions

 

 

 

 

Height

 

95

 

mm

Width

 

915

 

mm

Depth

 

553

 

mm

Build-in dimensions

 

 

 

 

Height

 

77

 

mm

Width

 

825

 

mm

Depth

 

467

 

mm

Type of gas used

Type of

Injector

Rated heat

Rated

Gas pressure [mbar]

 

burner

marking

capacity

consumption

 

 

 

 

 

[mm]

PCS-kW

 

 

 

 

 

 

 

 

 

min.

rat.

max.

City Gas

large

3,40

3,00

683 l/h

6

8

15

G 110

medium

2,00

1,70

387 l/h

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

large

1,45

3,00

285 l/h

15

18

23

(Methane)

medium

1,05

1,70

167 l/h

 

 

 

G 20

 

 

 

 

 

 

 

 

 

 

 

 

(G30)

 

 

Natural Gas

large

0,90

3,00

228 g/h

25

30

35

(Cylinder)

medium

0,71

1,70

133 g/h

(G31)

 

 

G 30 / G31

 

 

 

 

25

30

35

Loading...