Technical data
Electrical connection
Voltage 220 V Frequency 50 Hz
Dimensions
Height 95 mm Width 915 mm Depth 553 mm
Build-in dimensions
Height 77 mm Width 825 mm Depth 467 mm
SERVICE
Type of gas used Type of
burner
City Gas G 110
Natural Gas (Methane) G 20
Natural Gas (Cylinder) G 30 / G31
large
medium
large
medium
large
medium
Injector
marking
[mm]
3,40 2,00
1,45 1,05
0,90 0,71
Rated heat
capacity PCS-kW
3,00 1,70
3,00 1,70
3,00 1,70
Rated
consumption
683 l/h 387 l/h
285 l/h 167 l/h
228 g/h 133 g/h
Gas pressure [mbar]
min. rat. max.
6815
15 18 23
(G30)
25
(G31)
25
30 30
35 35