This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 27.08.2001Subject to modification
Document-No.: 4812 718 16928
27.08.2001 / Page 2ADG 7556 MWhirlpool Europe
Doc. No: 4812 718 169288542 556 01760Customer Service
Technical data
SERVICE
Dimension of Built In appliances Full Door and
Integretable types
Height82.0-87.0 cm
Width59.7cm
Depth55.5cm
Weight53kg
Wooden door for Full Door appliances
Thickness min.16mm
Thickness max.20mm
Width min.592mm
Width max.595mm
Height min.620mm
Height max.718mm
Weight min.2.5kg
Weight max.6.5kg
Max. stick out over lower
edge of appliance door92mm
Height of plinth min.93mm
Electronic boards
Service boardssee spare part list
Serial boardssee on the boards itself
UB4619 724 03582
DLB092221
Programing of version and programmed control
board, see „Service“ and „Data set“ on rating
plate of inner door:
CB programmed447061
Data set447051
Basic control board, not programmed see on the
board itself4619 724 17441
Succession of programs
Program information
End - Acoustic signal
All programs will be locked after start. Changing
the program or finishing the program will be
possible only after pressing the start button for
longer then 1.5 sec. (Break by customer)
A switching off the appliance or unplug the
appliance for a while, this will frozen the program
step and later on, the program continuos on the
same position.
Exception: Switching off the appliance or unplug
the appliance during the drying phase, this will lead
directly to the end of the program.
Water Volume at alternating spray system
Volume at alternating spray system (same level
when selected zone washing as in the normal
programs)
WaterVolumeLevel
Regeneration0.3 l15 mm
Back rinse 3x1.0 l60 mm
Prewash3.9 l120 mm
Main wash3.2 l118 mm
Intermediate rinse 13.2 l118 mm
Intermediate rinse 23.2 l118 mm
Clear rinse3.2 l118 mm
Safety/ overflow8.5 l141 mm
Spray pump motor2800RPM
Drain pump motor3000RPM
Spray arm lower30 - 40RPM
Spray arm upper30 - 40RPM
Spray arms, turning rhythm at alternating spray
system
Turning starts every time with the upper spray arm
Pre washLower arm ~3min, Upper arm ~1min
Main wash Lower arm ~3min, Upper arm ~5min
Intermediate rinse
Lower arm ~2min, Upper arm ~2min
Final rinse Lower arm ~2min, Upper arm ~2min
Service Test program
Lower arm ~30sec, Upper arm ~30sec
Electrical base data
Voltage220/ 230 V
Frequency50Hz
Total power2.0 - 2.2kW
Fuse10A
Motor
Spray pump motor alternating spray system
Voltage220/ 240 V
Power consumption125W
HI79Ω
HA60Ω
Capacitor4µ F
Drain pump motor
Voltage220/ 240 V
Power consumption30W
Resistance146Ω
Heating
Remark: When switching of the main switch or
interrupt the mains during the Test Program runs,
then the alternating of the spray arms change in
the test program to the rhythm of main wash 5/3
min.
Important: To leaf the Test program is possible by
made a break by customer (pushing the start
button for 1.5 sec.)
After finishing the test program (End LED shines
and/or Start LED goes of) must the appliance be
switched off.
If this will not be done, then the next normal wash
will be made with the frequency of the Service
Test Program ~30/30sec.
Flow rates/ Inlet volume
Flow meter (at 0.3 bar
= quantity 1.1 l/min)208lmp/l
Spray pump45 - 65l/min
Drain pump16l/min
Pump height max.1.1m
Inlet valve4l/min
Spray arm lower~ 33l/min
Sprayarm upper~ 27l/min
Shower top~ 8l/min
1 Element system
Voltage220/ 230 V
Power consumption1.87/ 2.04 kW
Resistance24.5Ω
Heating speed~ 2.0˚C/min
Temperature on surface~ 115˚C
Safety thermostat
self reset
(Temperature of water)~ 85˚C
Fuse206˚C
Potentiometer
Points of meassurement: 1(black) to 2 (middle)
Position 00.0kΩ
Position 10.5kΩ
Position 21.0kΩ
Position 31.4kΩ
Position 41.8kΩ
Position 52.3kΩ
Position 62.6kΩ
Double electric inlet valve
Voltage220/ 240 V
Frequency50/ 60Hz
Resistance2.0kΩ
27.08.2001 / Page 4ADG 7556 MWhirlpool Europe
Doc. No: 4812 718 169288542 556 01760Customer Service
Technical data
SERVICE
Regenerating valve
Voltage220/ 240 V
Frequency50/ 60Hz
Resistance3.13kΩ
Motor Diverter Valve
Voltage220 - 240 V
Frequency50/ 60Hz
Resistance6.5kΩ
Signal (2x within ~13 sec.) 5.0V
Coil of dispenser
Voltage220/ 240 V
Frequency50/ 60Hz
Resistance1.3kΩ
Reed contacts
flow meter
salt control
rinse aid control
Optical water indicator (OWI)
Optical measurement of the water in sump
Combination part of:
Turbidity sensor(DON)
Thermostat temp. sensor (notice NTC)