Whirlpool AC1888, AE0789, AE0989, AE1289, AE1889 Owner's Instructions Manual

...
AC0788
AC0988
AC1288
AC1888
AE0789
AE0989
AC0788
AC0988
AC1288
AC1888 AE0789
AE0989
N
N
N
N
N
N
N
N
Thank you for choosing Whirlpool air conditioner. Our design is based on the best efficiency and the lowest noise operation and it can keep the room comfortable. Please read this operating manual carefully before operating the unit and keep it for consultation.
CONTENTS
Function
Operating condition
Installation
and Installation
Notes for installation
Structure mechanism
Part identification
Air direction adjustment
Air conditioner opperation
Remote control operation procedure
Operation procedureCare and maintenance
Operation tips
Caution
1
2
3
5
6
6
7
10
13
14
Care and maintenance
Trouble shooting guide
After service
15
16
17
Function and working temperature range.
1
Introduction
Window type room air conditioners of Whirlpool can regulate the room temperature,dry the room. It is convenient for your work,study and life. It can be widely used in residence, shop, hotel, office, library and laboratory, and so on.
Cooling in summer
In hot summer, Air conditioner can cool down room air by transferring heat out.
Dehumidifying in rainy or humid season
Without reducing room temp, air conditioner can dehumidify and make room air dry and comfortable.
Operating Condition
2
Please operate air conditioner in the correct conditions as following.
COOL mode operation
Outdoor temperature should be in range of 21 to 52 , otherwise it is possible for air conditioner to breakdown. Room humidity should be lower than 90% . Otherwise, it is possible for air conditioner to dew at air conditioner surface and even drop water after running for so much time. But this maybe normal.
Power requirement
DRY mode operation
Outdoor temperature should be in range of 21
otherwise it is possible for air conditioner to breakdown.
to 52 ,
The ground must be connected. Special socket must be used. Furthermore, the socket and wiring must conform to the wiring regulations. And the earthing method must be reliable. In fixed circuit, there must be electricity leakage protection switch of enough power capacity and air switch with enough space.
Earth wire To ensure the reliable earthing, please do not connect earth wire to the following places:
Water pipe
How to install:
Choose a location where there are no any obstacle surrounding
the unit.
Prepare the installation hole slightly bigger than unit size. Choose the installation space according to the following diagram. The distance of obstructions from window unit inside should be
upper 300mm, lower 1500mm, left 500mm, right 500mm, front1500mm.
3
Installation procedure:
4
1) Remove the sticker from the front panel.
2) Put the unit into the installation hole. When installing the unit, it should be slanted down to the back to avoid the enlargement of noise or vibration. (Slant between 6-10mm.) (Shown at right figure.) The installation place should be strong enough to avoid the enlargement of noise or vibration.
3) Fill up sews in the cabinet with sponge or foam.
Installation assistance:
Horizontal line
Wall
Sunshade board
Wooden frame
Use iron support The installation hole should be strong enough to support the air conditioner. If it cannot, iron sup­port has to be used outdoors. Iron support should be fixed on the building (Shown at right figure.) Use sunshade board Air conditioner should avoid anything to be dropped into it and avoid direct sunshine. If there is no cover on it, you should contact the seller for installing the sunshade board. When installing the sunshade board, don’t let it block the air inlet at the side grille.
Rubber plate
Support
Horizontal line
Drain water:
To get the maximum cooling efficiency, the air conditioner is designed to splash the condensation water on the condenser coil. If the splashing sound annoys you, you can provide an outside drain by using the following procedure, which may however cause a small loss of performance.
1. Slide out the chassis from the cabinet.
2. Remove the rubber plug from the body base plate.
3. Install the drain pan to the corner of the cabinet with 2 screws.
4. Connect the drain hose to the outlet on the drain pan bottom.
5. Slide the chassis into its original place in the cabinet.
Note:
5
Drain hose or tubing can be purchased locally to satisfy your particular needs.
Notes for installation
Remove
Before removing air conditioner to the other place, you should contact the seller firstly. Then it must be done under the direction of the professional technician. In addition, the charge of this must be paid.
Noise
Install in a location where is firm enough to avoid the enlargement of noise and vibration. Don’t put anything in front of the outlet of outdoor unit to avoid increasing noise. Be sure that hot air or noise will not inconvenience neighbors. Please contact the seller as soon as there is strange noise during operation. Please use the safety support.
Electric wiring
Must connect with ground reliably. The exclusive circuit must be used. But removable socket can’t be used because poor contact of it can cause over heat or fire. Don’t pull the power cord strongly. In fixed circuit, there must be electricity leakage protection switch and leakage current is less than 30mA.
Connecting method between air conditioners and power cord and interconnecting method
of each individual element with one another should accord with wiring diagram on the unit.
The air conditioner should be installed in accordance with national wiring regulation.
An all-pole disconnection switch having a contact separation of at least 3mm in all poles
should be connected in fixed wiring
Air switch (thermal-magnetic breaker) should be installed in the circuit and its capacityis
10A for 7K and 9K, 15A for 12K, 20A for 18K, .
The fixed wiring should be more than
4.0mm2 in area.
PART IDENTIFICATION
6
Panel outlook picture, just for reference, please take the real unit as standard.
Cabinet
Air inlet louver
Front grille
(behind the front intake grille)
Air filter
Front intake grille
Control panel cover
Air direction adjustment
Vertical airflow direction vane
(Airflow direction adjustment up and down).
The vertical airflow direction vane is controlled by
positioning the vane to discharge the air upwards, downwards or straight out.
Power cord
AIR CONDITIONER OPERATION
7
Mechanical only
3 MINUTES WAIT BEFORE RESTARTING
8
Electronic only (control panel)
Note: If remote controller is lost, please open the panel and operate it by hand.
And DRY mode can't be chosen by hand.
AIR SWING
1 Power button
Press this button to turn on the unit. Press this button again to turn off the unit.
2 Swing button
Press this button to start up the auto swing function.
3 Fan speed button
4 Temp/time button
Press button to increase set temperature and press button decrease set temperature. The temperature adjusting range is 16-30. After pressing TIMER button, press button and time can be
set in 1-hour increments. Press button and time can be set in 1-hour decrements. The time adjusting
range is 0-24hours.
5 Signal receivers
6 Mode button
Press this button select operation mode: COOL, FAN.
9
Remote control operation procedure
10
Name and Function-Remote controller
Note: Be sure that there are no obstructions between reciever and remote controller. Don't drop or throw the remote controller. Don't let any liquid in the remote controller and put the remote controller
directly under the sunlight or any place where is very hot.
TIMER OFF:when the unit is turn on, press TIMER button to enter "timer off" state,then the timer lamp flash. Press + or - to increase or decrease   the timer.Press the TIMER button  once more to ensure the setting hours. TIMER ON:when the unit is turn off, press TIMER button to enter "timer  on" state,then the timer lamp flash, press + or - to increase or decrease  the timer.Press the TIMER button   once more to ensure the setting hours.
COOL
DRY
FAN
SPEED
TIMER
ON/OFF
FAN
SWING
FAN button Press  this  button,  the  fan  run  only. 
SWING button Press this button,the
swing function will be opened.Repress it again,
the swing function will
be stopped.
button
+、-  At operating,press + or -to increases the timer. Increase 1 hour by  pressing + button once, and derease 1 hour by  pressing - button.
Name and Function-Remote control
11
COOL  button Press  this  button,  the operation  mode  is  cooling
COOL
FAN
SPEED
FAN
FAN SPEED button Press  this  button  to
change  the  fan  speed  of: .  LOW  speed .  HIGH  speed
DRY  button When  it  is  pressed,  the operation  mode  is  drying
TEMP.  button SET  TEMP.increases  1  C  by pressing      C  button  once,and decreases  1  C  by  pressing    C  button  once. At  cool  mode  operation,SET  TEMP.can  be  selected  from  16  C  to  30  C. At  DRY  mode  operation,SET TEMP.  can  be  selected  from  16  C  to  30  C  .
DRY
TIMER
ON/OFF
SWING
ON/OFF  button Press  this  button  to  turn on  or  turn  off  the  unit.
How to insert batteries
12
1.Remove the screw with screwdriver.
2.Remove the cover from the
back of the remote control.
3.insert the two batteries (Two AAA dry - cell batteries).
4.Re - attach the cover.
NOTE:
Don’t confuse the new and worn or different types of batteries.
Remove batteries when
the remote controller is not in use for a longtime.
The lifetime of the bat-
teries is about one year. The remote controller should be placed about 1m or more away fr om the TV. or any other electric appliances. Bad batteries are for­bidden.
2
Remove the
cover.
4
Re - attach
the cover.
1
Remove the
screw
3
Insert the AAA batteries.
Operation Tips
13
Operation for comfort and economy
Do not overcool the room temperature, this is not good for health and waste electricity.
Make sure that the doors and windows are shut tightly.Avoid opening doors and windows as much as possible to keep the cool air in the room.
Do not let sunshine enter the room directly when the air con­dition is in operation.
Clean the air filter regularly. Blackages in the air filter re­duce dehumidifying effects. Clean at least once every two weeks.
Keep blind or curtains closed, Adjust the vertical and horizontal airflow direction to ensure a uni­form temperature in the room.
Ventilate the room occasionally. Since windows are kept closed, it is a good idea to open them and ventilate the room now and then.
14
Caution
1) The plug must be accessible after the appliance is positioned.
2) Do not use this appliance in the laundry.
3) If the power cord is damaged, it must be replaced by the manufacture or its service agent in void of hazard.
Do not pull out the power cord. Damage to the cord may result in serious electrical shocks.
Select the most appropriate temperature. Take care to adjust the tempera­ture to suit the conditions. Rooms occupied by infants,the elderly, or the sick should be kept at an appropriate temperature.
Do not use the air conditioner for other purposes such as dry­ing clothes, preserving foods, keeping animals, or cultivating vegetables.
Do not use heating apparatuses in the air conditioner’s plastic parts melt if exposed to exces­sive heat.
Do not block the air intake and outlet vents. This causes lowered perfor­mance and irregular operation. Do not insert sticks or other ob­jects into these vents as it is dan­gerous to touch the electric com­ponents and the fan.
Avoid exposing the body directly to a continuous unidirectional air flow for long periods. This is not recommended for health reason.
Always wait at least 3 minutes before switching the air condition on again after you have switched it off during cooling.
Always wait at least 3 minutes
Care and maintenance
15
Always turn off the air conditioner and main power supply before cleaning to ensure safety.
Clean unit
Air filter
1. Clean surface panel with a soft and dry cloth, Which is soaked warm water below 40
2. Do not use chemical solvent for cleaning.
.
The air filter behind the intake grille should be washed at least every two weeks or as often as it needs cleaning.
How to clean the air filter:
1. To remove the faceplate to the left in 15mm, and pull it to front and pull the air filter as show.
2. Vacuum the filter on the dusty side to remove light dust.
3. Wash the filter, cleaner side up under gently flowing water to wash out accumulated dust and lint.
Vacuum cleaner
3. Do not splash water directly to indoor unit, in which there are micro-
computer and circuit plate, they must not be touched by water.
Check earth wire
*
Is it broken or loose?
4. If the filter is very dirty, use a mild household detergent in the wash water.
Let the filter dry thoroughly before reinstalling it.
Check air inlet and outlet of outdoor unit.
*
Air lock could result in bad efficiency.
Trouble shooting guide
16
Please check the following items before asking for repair,it saves your time and money.
Fault phenomenon Trouble-shooting
* Is there a power failure?
Air conditioner dose not operate at all.
Cool efficiency is not good.
* Is the plug out? * Is power fuse or switch off ?
Whether the voltage is too high or too low?
*
* Is air inlet or outlet locking? * Is there any other heat source in room? * Are air filters dirty very much? * Is indoor fan speed set at LOW?
* Maybe the room is too hot when the unit is started,
please cool down the room after a period of time.
Foggy air flows out.
The air conditioner opera­tion is noisy.
It seems that condensation is leaking from air conditioner.
Air conditioner dose not operate for about 3 minutes when restart.
* At COOL mode operation, sometimes there is foggy
air flowing out of indoor unit, this is because the room humid air has been cooling rapidly.
* The unit is normal while the indoor outlet is sending
out some odor, because the inlet air may be mixed with the smell of furniture and smoke.
* For a noise that sounds like water flowing: This is the sound of freon flowing inside the air con-
ditioner unit. * For a noise that sounds like a shower: This is the sound of the dehumidifying water being
processed inside the air conditioner unit.
* Condensation occurs when the airflow from the air
conditioner cools the warm room air.
* This is to protect the mechanism. * Wait about three minutes and operation will begin.
Immediately stop all operations and plug out, please contact your dealer
17
in the following situations.
*Operation starts or stops abnormally; *Power fuse or switch often breaks; *Carelessly splash water or something into air conditioner; *Electrical lines are much hot or lines cover breaks; *Other strange situations.
After service
If your air conditioner has the questions of quality or anything else, please contact the service center of Whirlpool.
Whirlpool Corporation
網站:http://www.whirlpool.com
66129912918
Loading...