Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all
safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or
“WARNING.” These words mean:
You can be killed or seriously injured if you don't
immediately follow instructions.
can be killed or seriously injured if you don't
You
follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what can
happen if the instructions are not followed.
2
WARNING:
To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions:
Plug into a grounded 3 prong outlet.
IMPORTANT SAFETY INSTRUCTIONS
Do not use an extension cord.
Do not remove ground prong.
Do not use an adapter.
SAVE THESE INSTRUCTIONS
INSTALLATION REQUIREMENTS
Tools and Parts
Check that you have everything necessary for correct installation.
Proper installation is your responsibility.
Too ls ne eded
■ Safety glasses
■ Flat-blade and Phillips
screwdrivers
■ ¹⁄₄ in. nut driver
■ ⁷⁄₁₆ in. wrench
Parts supplied
Check that all parts are included in parts package.
Air conditioner installation
6
■ Scissors
■ Tape measure
■ Level
■ Drill
■ ³⁄₃₂ in. or smaller drill bit
7
Unplug air conditioner before servicing.
Use two or more people to move and install air conditioner.
SMART-MOUNT
™
tray assembly installation
1
2
3
4
5
6
1. 1 tray back
2. 1 tray center
3. 2 tray sides
4. 2 support legs
5. 4 - #8 - 18 x
head screws
7
8910
¹⁄₄
in. hex-
6. 4 flat washers
7. 4 lock washers
8. 4 hex nuts
9. 4 carriage bolts
10. 2 - #10 - 12 x 1
slot-head wood screws
¹⁄₂
in.
1
1. 1 window-lock bracket
2. 6 - #8 x
3. 3 - #8 x
4. 3 - #10 x
³⁄₈
in. pan-head screws
³⁄₄
in. round-head screws
³⁄₈
2
in. pan-head screws
8
5
Location Requirements
4
3
5. 2 side curtains
6. 1 top channel
7. 1 foam seal
8. 2 side curtain frames
IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed.
Proper installation is your responsibility. Make sure you have
everything necessary for correct installation.
The location should provide:
■ Grounded electrical outlet within 4 ft (122 cm) of where
the power cord exits the air conditioner.
NOTE: Do not use an extension cord.
■ Free movement of air to rooms to be cooled.
■ A large enough opening for the air conditioner. Installation
parts are supplied for double-hung windows.
■ Adequate wall support for weight of air conditioner. Air
conditioner weighs 80 lbs (36.3 kg) to 125 lbs (56.7 kg).
3
NOTE: Cabinet louvers must not be obstructed. Air must be able
to pass freely through the cabinet louvers.
1
1. Cabinet louvers
Window installation
Window opening measurements:
■ 27 in. (68.6 cm) minimum to 40 in. (101.6 cm) maximum
opening width.
■ 19 in. (48.3 cm) minimum opening height.
A
B
A. 27 in. (68.6 cm) minimum
B. 19 in. (48.3 cm) minimum
Electrical Requirements
WARNING
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power supply cord
Wiring requirements
plug outlet
■ 115 volt (103.5 min. -
126.5 max.)
■ 0-12 amperes
■ 15-amp time-delay fuse or
circuit breaker
■ Use on single outlet circuit
only.
■ 230 volt (207 min. -
1
/4"
(0.6 cm)
253 max.)
■ 0-12 amperes
■ 15-amp time-delay fuse or
circuit breaker
■ Use on single outlet circuit
only.
Recommended ground method
For your personal safety, this air conditioner must be grounded.
This air conditioner is equipped with a power supply cord having
a grounded 3 prong plug. To minimize possible shock hazard, the
cord must be plugged into a mating, grounded 3 prong outlet,
grounded in accordance with all local codes and ordinances. If a
mating outlet is not available, it is the customer's responsibility to
have a properly grounded 3 prong outlet installed by a qualified
electrical installer.
It is the customer's responsibility:
■ To contact a qualified electrical installer.
■ To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 -
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located on the right-hand side of the cabinet.
4
INSTALLATION INSTRUCTIONS
Unpack the Air Conditioner
WARNING
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
1. Using the tray back as a template, center in windowsill
against outside edge of stool.
3
2
Remove packaging materials
■ Remove and properly dispose of packaging materials.
Remove tape and glue residue from surfaces before turning
on the air conditioner. Rub a small amount of liquid dish soap
over the adhesive with your fingers. Wipe with warm water
and dry.
■ Do not use sharp instruments, rubbing alcohol, flammable
fluids, or abrasive cleaners to remove tape or glue. These
products can damage the surface of your air conditioner.
SMART-MOUNT™ Tray Installation
1
1. Tray back
2. Windowsill
3. Outside edge of stool
2. Using the 2 inside screw holes in tray back, mark screw
locations on windowsill for mounting the SMART-MOUNT
tray.
™
3. Remove tray back. Using these marks, drill ³⁄₃₂ in. pilot holes
in the windowsill approximately 1¹⁄₂ in. deep.
4. To assemble the tray frame, insert tab on tray back into slot
on tray side. Check to see that the tab is engaged and the
2 pieces are aligned. Insert 2 - #8 - 18 x ¹⁄₄ in. hex-head
screws to secure.
5. Repeat with other tray side.
2
1
1. Tray back
2. #8 - 18 x
3. Tray side
¹⁄₄
in. hex-head screws
3
5
Attach support legs
4
1. Determine the correct slots on the tray side from the type of
exterior construction of the building.
Thin wall construction (vinyl, wood, etc.)
1
1. 1st and 2nd slots
Thick wall construction (brick)
1
3. Place one end of tray center over carriage bolt.
4. Then place flat washer, lock washer and hex nut.
NOTE: Do not tighten. The leg must be able to move freely to
adjust angle when installed.
1
2
3
4
5
1. 2nd and 3rd slots
2. Insert carriage bolt up through slot on tray-frame side and
support leg.
1. Hex nut
2. Lock washer
3. Flat washer
4. Tray center
5. Carriage bolt
5. Insert second carriage bolt through tray side and attach other
end of support leg.
NOTE: Do not tighten. The leg must be able to move freely to
adjust angle when installed.
1
2
3
1. Hex nut
2. Lock washer
3. Flat washer
4. Carriage bolt
6. Install support leg on other side.
6
Install in window
1. From inside, place SMART-MOUNT™ tray, support legs facing
down, in the window. Match the holes in tray side with the
predrilled holes in windowsill.
2. Using 2 - #10 - 12 x 1¹⁄₂ in. slot-head wood screws, secure
the tray-frame assembly to the window.
1
Prepare Air Conditioner for Installation
1. Locate provided bag of pan-head screws.
2. Place the top channel on top of the air conditioner, lining up
the holes in top channel with the holes on top of air
conditioner.
3. Using 3 - #10 x ³⁄₈ in. pan-head screws, attach top channel to
air conditioner.
1
2
1. #10 - 12 x 1
¹⁄₂
in. slot-head wood screws
NOTE: If the exterior of building can be damaged by support
legs, place a board between the wall and support legs.
3. With tray center pushed away from the windowsill, place a
level on the angled edge of tray side. Check to be sure level is
against notch on tray side. Adjust SMART-MOUNT
™
tray until
bubble indicates level.
1
1. Place level on angled edge
against notch on tray side
4. Tighten the hex nut just enough to hold tray center in place.
5. Repeat with other side.
6. Tighten hex nuts securely with ⁷⁄₁₆ in. wrench.
1. Top channel
2. #10 x
³⁄₈
in. pan-head screw
Install side curtains
NOTE: Attach curtains to unit before placing unit in window.
1. Insert curtain into curtain frame. Make sure the curtain end
locks into curtain frame.
2. Push curtain in all the way.
7
3. Pull curtain toward open end of curtain frame.
4. Insert top and then bottom of right-hand curtain frame in top
and bottom curtain guides on air conditioner.
Top view
5. Extend right-hand curtain outward so you may insert the first
screw through the middle hole of the curtain. Using a #8 x
³⁄₈ in. pan-head screw, screw curtain to middle hole in air
conditioner cabinet.
NOTE: This screw is required to correctly attach curtain (top
to bottom) to the air conditioner cabinet.
1
1. #8 x
³⁄₈
in. pan-head screw
6. While the right-hand curtain is still extended, insert screws
into top and bottom slots of curtain. Using #8 x ³⁄₈
head screws, screw curtain to the top and bottom holes in air
conditioner cabinet.
7. Slide curtain housing into guides as far as it will go.
8. Repeat above steps for left-hand curtain.
in. pan-
Bottom view
Position the Air Conditioner
■ Handle air conditioner with care.
■ Be sure your air conditioner does not fall out of the opening
during installation or removal.
■ The place where the power cord exits the air conditioner
should be no more than 4 ft (122 cm) from a grounded outlet.
■ Do not block the louvers on the front panel.
■ Do not block the louvers on the outside of the air conditioner.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
1. Put air conditioner on SMART-MOUNT™ tray. Check that feet
on bottom of air conditioner are behind and against back side
of windowsill. Lower window sash.
8
3. If the bottom of the air conditioner does not sit against the
bottom of the SMART-MOUNT
™
tray, remove air conditioner
and adjust angle of tray until air conditioner sits against the
1
bottom of the tray.
2
1. Window sash
2. Feet on bottom of air conditioner
behind back side of windowsill
2. If window sash does not close flush against rear surface of
top channel, remove air conditioner and adjust SMARTMOUNT
™
tray until window sash closes flush against rear
surface of top channel.
Correct installation
1
2
3
1
2
1. Air conditioner sitting on SMART-MOUNT™ tray
2. SMART-MOUNT
™
tray
Attach side curtains to window
1. Pull left-hand curtain frame out until it fits into the window
channel. Repeat with right-hand curtain frame.
2. Insert one of the #8 x ³⁄₄ in. round-head screws through left-
hand curtain frame and into the window channel to fasten the
curtain frame to the window.
3. Repeat for right-hand curtain frame.
Front view
1
1. Window sash
2. Top channel
3. Air conditioner
If your air conditioner looks like either of the illustrations in the
“Incorrect installation” graphic, SMART-MOUNT
™
tray needs
adjustment.
Incorrect installation
1
2
2
3
1. Window sash
2. Top channel
3. Air conditioner
2
Top view
1. Hole for #8 x
2. Side curtain
³⁄₄
in. round-head screw
2
1
3
1. Side curtain against window channel
2. Window channel
3. #8 x
³⁄₄
in. round-head screw
9
Complete Installation
2
1. Place window-lock bracket on top of lower window and
against upper window sash.
2. Use a ³⁄₃₂ in. drill bit to drill a starter hole through the hole in
the bracket into the window sash.
3. Attach window-lock bracket to window sash with #8 x ³⁄₄ in.
round-head screw to secure window in place.
1
2
1. Upper window sash
2. Window-lock bracket
4. Insert foam seal behind the top of the lower window sash and
against the glass of the upper window.
1
AIR CONDITIONER USE
Operating your air conditioner properly helps you to obtain the
best possible results.
This section explains proper air conditioner operation.
IMPORTANT:
■ If you turn off the air conditioner, wait at least 3 minutes
before turning it back on. This prevents the air conditioner
from blowing a fuse or tripping a circuit breaker.
■ Do not try to operate your air conditioner in the cooling mode
when outside temperature is below 65°F (18°C). The inside
evaporator coil will freeze up, and the air conditioner will not
operate properly.
NOTE: In the event of a power failure, your air conditioner will
operate at the previous settings when the power is restored.
Starting Your Air Conditioner -
Digital Control
1. Lower window sash
2. Foam seal
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
5. Plug into a grounded 3 prong outlet.
1. Remove clear protective film from control panel and front
panel badge.
2. Press POWER to turn on air conditioner.
NOTE: When air conditioner is turned on for the first time
after it is plugged in, it will display the default settings: Cool
mode, Turbo fan speed, 72°F (22°C). When it is turned on at
all other times, it will display the previous settings.
3. Select mode. See “Mode.”
4. Select fan speed. See “Fan Speed.”
5. Set temperature. See “Temperature.”
10
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.