Safety information
Your safety and the safety of others
is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards
A
You wlil be killed or seriously injured if you don’t follow instructions.
You can be killed or seriously injured if you don’t follow instructions.
All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
that can kill or hurt you and others. All safety messages will be preceded by the safety alert symbol and the word “DANGER” or
“'WARNING.” These words mean:
A DANGER A WARNING

IMPORTANT SAFETY INSTRUCTIONS

WARNING —To reduce the risk of fire, electrical shock, injury or sickness when using your dehumidifier, follow these basic precautions:
Plug into a grounded 3 prong outlet.
• Do not remove ground prong.
• Do not use an adapter.
• Do not use an extension cord.
— SAVE THESE INSTRUCTIONS —
It is your responsibility to:
• Install the dehumidifier according to the Installation Instructions.
• Connect the dehumidifier only to the proper kind of outlet, with the correct electrical supply and ground. See “Electrical requirements," page 3.
Unplug dehumidifier before servicing.
Do not drink water collected in the water bucket.

Electrical requirements

^WARNING

!lr
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these
instructions can result in death,
fire, or electrical shock.
A 115-volt (103.5 min., 126.5 max.), 60-Hz, AC-only, 15- or 20-ampere fused and properly grounded electrical supply is required. A time-delay fuse or time-delay circuit breaker is recommended. Use a separate circuit to connect only the dehumidifier.

Grou ndi ng ins tru cti on s:

3-prong ground-tirpe
power supply cord
For your personal safety, this dehumidifier must be grounded.This dehumidifier is equipped with a power supply cord having a 3-prong ground plug.
To minimize possible shock hazard, the cord must be plugged into a mating 3-prong ground-type outlet, grounded in accordance with local codes and ordinances. If a mating outlet is not available, it is the personal
responsibility and obligation of the customer to have the properly grounded outlet installed by a qualified electrician.
c
Installing dehumidifier
Good air circulation is needed for best performance—allow at least 12-18 inches (30.5 -
45.7 cm) of air space on all sides of the dehumidifier.
12-18"
(30.5-45.7 cm)
Install dehumidifier on a level floor strong enough to support the dehumidifier with a full bucket of water.

65° (18. 3°C)

Install your dehumidifier in an area
where the temperature will not fall
below 65°F (18.3°C). Lower temper atures will cause ice to form on coils.
65 °-

(18. 3°C)

If ice forms on coils, some dehumidifiers will continue to run. Some dehumidifiers have a de-icer feature that will automatically shut the compressor off when ice forms. (Fan continues to run.) Unplug either type of dehumidifier until ice melts and room temperature rises.
Keep all outside doors, windows and other openings closed when operating dehumidifier. Humid outdoor air will increase dehumidifier workload.
(30i-45.7cm)

Operating dehumidifier

EMPT Y/AD JU ST B UC KET li ght : DRYNE SS CON TRO L:

If this light is on, the dehumidifier is not running.This light indicates that
you need to check:
• If the bucket is full, empty bucket and replace.
• If the bucket is not in position,
remove bucket and replace. Make sure the bucket fits all the way into the dehumidifier and the light is off, or dehumidifier will not run.
This controls the amount of moisture in the room.Turn the control knob
clockwise for more drying.Turn the control knob counterclockwise for less drying.Turn control knob to "NORMAL" to maintain average humidity conditions. NOTE: For the first few days of use, turn the Dryness Control clockwise to "DRYEST"to remove extra moisture
Some models: this controls fan operation. Use desired setting.
HIGH - for faster moisture removal. LOW - for slower moisture removal.

Removing & emptying water bucket

m

AWARNING

Sickness Hazard
Do not drink water collected in water bucket. Doing so can result in sickness.

Bucke t sty les :

Bucke t meth od :

Bucket style 1
2. Carry bucket to a large sink or tub.
1. Use both side handles to lift bucket. Pull bucket forward and remove.
Go to Step 2.
Bucket style 2
I.Lift bucket from bottom. Pull bucket
forward and remove. Go to Step 2.
3. Pour water through opening into a sink or tub.
4. Replace bucket completely and
check that EMPTY/ADJUST BUCKET light is off.

Removing & emptying water bucket

Drain h ose co nne cti on met hod :

(to drain water from bucket continuously)
Bucket style 1
drain hose connector cover (not on all models)
1. If your dehumidifier does not have a drain hose connector cover, go to
Step 2.
If your dehumidifier has a drain
hose connector cover, use a flat-
blade screwdriver to remove cover
from drain connector.Turn cover
counterclockwise. Discard cover. It cannot be reused. Go to Step 2.
Bucket style 2
.. Do Not
damage outside or connection will leak.
center of drain hose connector
2. Drill out only the center of the drain hose connector. Use a minimum 1/4" drill bit.
3. Attach a garden hose to drain hose connector.The garden hose should not be longer than 8 feet (2.4 m). Run other end of garden hose into a floor drain. Check that the hose lies flat and in the drain.
1. Slide off the drain hose connector cover. Go to Step 2.
To use the bucket without the garden hose:
For bucket style 1:
Use a garden hose cap to seal the drain hose connector.
For bucket style 2:
Use a garden hose cap to seal the drain hose connector. Replace drain hose connector cover.

Water level float & automatic shutoff

c
All dehumidifiers have automatic shutoff and a water level float. Some dehumidifiers feature an adjustable Water Level Float.The bucket must be properly aligned for the Water Level Float to work.

For model s with non-ad jus tab le Water Le vel Fl oa t

The Water Level Float will shut off the dehumidifier automatically.
For model s with adjust abl e
Water Le vel Fl oa t:
You can set the adjustable Water Level
Float at the "high" or "low" position. Both settings will turn off the dehumidifier automatically.
"High" setting: Water Level Float is
preset to the "high" position—left side
of opening.The dehumidifier will shut off automatically when bucket is 3/4 full.
"Low" setting; Slide Water Level Float to
"low" position—right side of opening
— to make the bucket lighter to carry. The dehumidifier will shut off
automatically when bucket is 1/2 full.