wheelock TPA-60-B, TPA-100-B INSTALLATION INSTRUCTIONS

273 Branchport Avenue Long Branch, N.J. 07740 (732) 222-6880
INSTALLATION INSTRUCTIONS
MODEL TPA-60-B/TPA-100-B
PAGING AMPLIFIERS
GENERAL APPLICATION INFORMATION
:
Wheelock models TPA-60-B and TPA-100-B Paging Amplifiers are output rated at 60 watts RMS and 100 watts RMS respectively.
These amplifiers afford a choice of five different inputs: two low impedance microphone inputs, one telephone paging input, and two high impedance auxiliary inputs. Three input channels allow three of these inputs to be used actively at one time: one microphone input, a choice of a telephone paging input or a second microphone input, and a choice of either one of two auxiliary inputs. Note that the auxiliary input (i.e., background music, tone generator, etc) will automatically be soft muted whenever a telephone page is generated or a microphone is used. After completion of the page, the music will rapidly return to its original level.
A built-in limiter circuit (ALC) compensates for the varying voice levels and paging styles of the people who have access to telephone paging or a microphone. The limiter maintains rated output without distortion.
The amplifiers feature individual input volume controls, as well as a master volume control, individual treble and bass controls, a low-cut horn protect switch, two input selector switches, an illuminated power on switch, an internal ALC (limiter) ON-OFF switch, an internal mute ON-OFF switch, a peak level indicator, and a line output jack.
Both models operate from 120 volts, 60Hz and have a power consumption of 180 watts (TPA-60-B) and 240 watts (TPA­100-B). The units have a circuit breaker on the AC line input as well as a thermal breaker for overload protection on the output. The AC circuit breaker is manually resettable. IN THE EVENT THE CIRCUIT BREAKER DOES NOT RESET, HAVE THE TROUBLE INVESTIGATED BY AN AUTHORIZED SERVICE TECHNICIAN OR RETURN UNIT TO THE FACTORY.
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE.
UNPACKING
: The amplifier was carefully checked before leaving the factory. Inspect shipping container and unit carefully for indication of improper handling. If the unit has been damaged, make an immediate claim to the carrier.
MOUNTING INSTRUCTIONS
: The amplifier is provided with a set of universal mounting brackets to facilitate either rack or surface wall mounting. Remove the 8 screws (4 on either side) holding the cover to the chassis. Choose the mounting required (rack or surface wall), and insert screws through the universal mounting bracket and back into the cover/chassis holes as shown in Figures 1 and 2.
CAUTION:
THESE DEVICES ARE NOT INTENDED FOR USE IN HAZARDOUS LOCATIONS AS DEFINED BY THE NATIONAL ELECTRICAL CODE (NEC) AND BY THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA).
P82423 C
Sheet 1 of 10
RACK MOUNTING
FIGURE 1.
SURFACE WALL MOUNTING
For surface mounting, be sure to use hardware suitable for the mounting surface.
FIGURE 2.
POWER AND GROUNDING
: The 120 VAC line cord has a three-prong plug which should be plugged into a three wire grounded electric outlet. It is very important to maintain the amplifier ground for safe and trouble-free operation. If there is no grounded electric outlet, connect a wire from the GND terminal on the OUTPUT terminal strip to a water or steam pipe.
P82423 C
Sheet 2 of 10
TECHNICAL SPECIFICATIONS
:
# PARAMETERS TPA-60-B TPA-100-B
1 POWER OUTPUT
@ 1 KHz
2 TOTAL HARMONIC
DISTORTION
3 OUTPUTS
4 LINE
OUTPUT
INPUTS
5 IMPEDANCE
6 SENSITIVITY
7 FREQ. RESPONSE
8 SIGNAL TO NOISE
RATIO
9 TYPE OF INPUT XFMR
10 CONTROLS TEL/MIC 1, MIC 2, AUX 1/AUX 2, INPUT LEVELS,
11 INDICATORS AMBER OR RED NEON - POWER ON RED LED -
12 PROTECTION AC LINE RESETTABLE CIRCUIT BREAKER AND
13a TREBLE CONTROL
13b BASS CONTROL
14 LO-CUT SWITCH -6 dB @ 250 Hz 15 AUTOMATIC LIMITER
FOR PAGING
16 AUTOMATIC MUTE
OPERATION
17 REGULATION
18 CONSUMPTION
19 SIZE 15"W X 11.25"D X 4.125"H
20 WEIGHT 15lbs. (6.75Kg) 18lbs. (8.1Kg)
TELEPHONE
600 ohm 600 ohm 47K ohms
-20 dBm 1 mV 220 mV
300Hz - 4KHz 70Hz - 15KHz 70Hz - 15KHz
ISOLATED/BAL
BASS, TREBLE, MASTER VOLUME, TEL/MIC 1 AND AUX 1/AUX 2 SELECTOR SWITCHES, POWER ON/OFF SWITCH, LO-CUT SWITCH, ALC (LIMITER) ON-OFF SWITCH (INTERNAL), AUX MUTE ON-OFF SWITCH (INTERNAL).
PEAK LEVEL
THERMAL OVERLOAD PROTECTION ON OUTPUT.
+/-3 dB OUTPUT LEVEL MAINTAINED WITHOUT CLIPPING, EVEN WHILE EXCEEDING RATED INPUT LEVEL UP TO 20 dB. OUTPUT LEVEL 1 WATT FOR 40 dB MUTING
NO LOAD TO FULL LOAD OUTPUT LESS THAN 2 dB.
180 WATTS MAX. 280 WATTS MAX.
60 WATTS RMS
LESS THAN 2% THD
4 ohms, 8 ohms, 25V, 70V
150 ohm, 1.1VRMS
MIC 1/MIC 2
65dB 60dB 75dB
BALANCED OR UNBAL.
-10.5 dB TO +10.5 dB @ 12 KHz
+10.5 dB TO -10.5 dB @ 100 Hz
(38.1 X 28.6 X 10.1cm)
100 WATTS RMS
AUX 1/AUX 2
UNBALANCED
P82423 C
Sheet 3 of 10
INPUT CONNECTIONS
(FIGURES 3 & 4)
TELEPHONE PAGING INPUT (FIGURE 3)
: Connect telephone wires to the input screw terminals marked TIP and RING.
Set TEL/MIC 1 Switch (on front panel) to TEL position. For Tip and Ring connections to various types of telephone
Loading...
+ 7 hidden pages