wheelock TB-591-592 INSTALLATION INSTRUCTIONS

273 Branchport Avenue Long Branch, NJ 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc.com
INSTALLATION INSTRUCTIONS
Use this product according to this instruction manual. Please keep this instruction manual for future reference.
MODEL NO: TB-591, TB-592
GENERAL:
The TB series Telbells are designed to provide a loud attention getting bell sound for use in noisy locations or for wide area coverage. It includes an externally adjustable, tamper resistant volume control. Telbell utilizes the motor driven mechanism concept that incorporates a high torque permanent magnet motor and a 6" aluminum shell to produce higher sound output and lower resonant frequency than conventional mechanical bells. The TB series are designed for use with telephone communications systems whose ringing voltages are from 18-30VAC/DC, or 38-60VDC.
Telbells are attractively packaged for convenient indoor or outdoor surface mounting. Wiring is easy because a modular telephone jack is provided. Additionally, they provide screw terminals for hard wiring, and a knockout for 1/2" conduit.
READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT.
NOTE: All CAUTIONS and WARNINGS are identified by the symbol
. All warnings are printed in bold capital letters.
INSTALLATION INFORMATION:
The TB series Telbells are intended for surface mounting. To install the Telbell, follow instructions below:
1. Modular Connection - Figure 1 & 2: a. Unscrew the center bolt to remove the bell shell. b. Mount the base to the desired location, using mounting hardware suitable for the mounting surface material. c. Mount bell shell to housing with center bolt. Be sure shell is properly aligned with housing.
NOTE: Pin hole in bell shell must be aligned with guide pin on bell housing.
d. Route the telephone cord through the bushing (provided) and plug the telephone cord into the unit modular phone jack,
then plug the bushing into the backbox per Figure 2.
e. Test by having someone ring your telephone to make sure the signal functions properly.
NOTE: The factory volume control setting is at maximum. Readjust volume as required. For tamper resistant volume setting,
remove volume control shaft by pulling straight out.
2. Hard Wire Connection - Figures 3 & 4: a. Unscrew the center bolt to remove the bell shell. b. Remove the bell housing by unscrewing all four screws. Disconnect the red and black wires by unplugging from the PC
Board. c. Mount the backbox to the desired location, using mounting hardware suitable for the mounting surface material. d. No conduit:
Route the 24VDC or 48VDC wires through the bushing (provided) and connect wires to terminal TB1 marked T and R
respectively. Then plug the bushing into the phone jack opening of the backbox, See Figure 4.
With conduit:
Open the knock-out in the top of backbox. Be careful not to damage PC Board components. The knock-out opening is
sized for 1/2" conduit and matching connector. Be sure that proper water tight conduit fitting is used to connect to the bell
backbox for outdoor application. Connect 24VDC or 48VDC wires to terminal TB1 marked T and R respectively.
Copyright 2002Wheelock, Inc. All rights reserved.
P81897 L
Sheet 1 of 3
NOTE: The Telbells are not polarity sensitive. They will function even though the polarity is reversed.
(
)
e. Reconnect red and black wires to pins marked red and black respectively on the PC Board. f. Mount the bell housing to the backbox, with the four screws. g. Mount bell shell to housing and secure with center bolt. Be sure shell is properly aligned with housing.
NOTE: Pin hole in bell shell must be aligned with guide pin on bell housing.
h. Plug the bushing into the phone jack opening of the backbox. i. Test by having someone ring your telephone to make sure the signal functions properly.
NOTE: -The factory volume control setting is at maximum. Adjust volume as required. For tamper resistant volume setting,
remove volume control shaft by pulling straight out.
- At low input voltages, and low volume settings, the volume control may have to be adjusted to obtain the desired sound
NOTE: The Telbell does not eliminate existing telephone ringers. Such ringers can be disconnected when Telbell is installed.
output.
CAUTION: These devices are not intended for use in hazardous locations as defined by the National Electrical Code (NEC) and by the National Fire Protection Association (NFPA). Contact Wheelock Inc. for information on explosion-proof devices designed for hazardous locations.
Table 1: Performance Specifications
Model Number TB-591 TB-592 Nominal Input Voltage 48VDC 24VDC/AC Input Voltage Range 38-60VDC 18-30VDC/AC Input Current at Nominal Input Voltage 25mA 25mADC/30mAAC Sound Pressure Level Min/Max Volume 95/100dB at 1 Meter Minimum "ON" Cycle 0.5 Seconds Minimum "OFF" Cycle 0.5 Seconds Shell Size 6" Aluminum DC Impedance Virtually Infinite (Blocking Capacitor)
BELL SHELL
Input Jack USOC RJ11C (PIN 2 - Black; PIN 5 - Yellow)
OBSERVE "TOP" MARKING
(2) 1/2" CONDUIT
KNOCKOUTS
TOP
BACKBOX
BUSHING
TO TELEPHONE SYSTEM
EXTRA ALERT CARTRIDGE
OR SERVICE MODULE,
LOUD
SOFT
GUIDE PIN
BELL
MOUNTING BOLT
Figure 1: Removal of Bell Shell Figure 2: Modular Connection
OBSERVE "TOP" MARKING
(2) 1/2" CONDUIT KNOCKOUTS
PC BOARD
BELL SHELL
MOUNTING BOLT
Figure 3: Removal of Bell Shell and Housing Figure 4: Hard Wire Diagram
HOUSING
ALIGN PIN HOLE WITH GUIDE PIN
BELL HOUSING
GUIDE PIN
BACKBOX
TOP
(2) SCREWS
ALIGN PIN HOLE WITH GUIDE PIN
25 FT MODULAR LINE CORD
PROVIDED
FOR WIRE ENTRANCE ONLY
FOR CONDUIT
ENTRANCE ONLY
FOR CONDUIT
VOLUME
(2) KNOCKOUTS FOR 1/2" CONDUIT & MATCHING CONNECTOR
PC BOARD
VOLUME CONTROL
T R
TB1
BASE (SHOWN WITH BELL
BUSHING
HOUSING REMOVED)
OR SUPPLEMENTARY ALERT
ADAPTER, AS APPLICABLE.
P81897 L
Sheet 2 of 3
Loading...
+ 1 hidden pages