Westinghouse WRCG930SB, WRCG940SB User Manual

INSTALLATION & USER MANUAL
CANOPY RANGEHOOD
WRCG930SB, WRCG940SB
WARNING
WARNING
TIPS & INFORMATION
ENVIRONMENTAL TIPS
CONTENTSCONGRATULATIONS
Dear customer,
Congratulations and thank you for choosing our canopy rangehood. We are sure you will find your new rangehood a pleasure to use. Before you use your rangehood, we recommend that you read through the whole user manual, which provides the description of the rangehood and its function.
To avoid the risks that are always present when you use an electrical appliance it is important that the canopy rangehood is installed correctly and that you read the safety instructions carefully to avoid misuse and hazards. We recommend that you keep this instruction booklet for future reference and pass it on to any future owners. After unpacking the canopy rangehood please check it is not damaged. If in doubt, do not use the appliance but contact your local Electrolux Service Centre.
Conditions of use
This appliance is intended to be used in household and similar applications such as:
• Staff kitchen areas in shops, offices and working henvironments
• Farm houses
• By clients in hotels, motels and other residential type environments
• Bed and breakfast type environments
• Catering and similar non-retail applications
Important safety instructions ........................................................3
Product description ...........................................................................5
Before using your appliance for the first time ................... 6
Installing oven accessories .............................................................7
Using your oven ................................................................................. 8
Cooking guide ...................................................................................14
Grilling guide ...................................................................................... 15
Dealing with cooking problems .................................................16
Getting to know your oven ..........................................................17
Cleaning your appliance ...............................................................18
Cleaning the oven door .................................................................20
Troubleshooting ................................................................................24
Installing your appliance ...............................................................25
Gas installation information ....................................................... 30
Warranty ...............................................................................................35
The symbols you will see in this booklet have these meanings:
WARNING
This symbol indicates information concerning your personal safety.
Please ensure you read the instruction manual fully before you call for service, or a full service fee could be applicable.
Record model and serial number here:
Model number:........................................................................................
Serial number: .........................................................................................
PNC: .............................................................................................................
CAUTION
This symbol indicates information on how to avoid damaging the appliance.
IMPORTANT
This symbol indicates tips and information about use of the appliance.
ENVIRONMENT
This symbol indicates tips and information about economical and ecological use of the appliance.
CONTENTS
2 CONTENTS
TIPS & INFORMATION
ENVIRONMENTAL TIPS
WARNING
IMPORTANT SAFETY INSTRUCTIONS
This manual explains the proper use of your new Westinghouse canopy rangehood. Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. This canopy rangehood is a domestic appliance which has been manufactured and tested to comply with Australian and New Zealand Standard AS/NZS 60335.2.31.
IMPORTANT
Important – check for any damages or marks
If you find the rangehood is damaged or marked, you must report it within 7 days if you wish to claim for damage/marks under the manufacturers warranty. This does not affect your statutory rights.
Unpacking
Check that the cooker hood has no damage. Transportation damage should immediately be reported to the company responsible for the transportation Damage, faults and missing details should immediately be reported to the retailer. Take care of the packing materials so that small children cannot play with them
ENVIRONMENT
Information on disposal for users
• Most of the packing materials are recyclable. Please dispose of those materials through your local recycling depot or by placing them in appropriate collection containers.
• If you wish to discard this product, please contact
your local authorities and ask for the correct method of disposal.
These warnings have been provided in the interest of safety. You MUST read them carefully before installing or using the appliance.
The appliance must be plugged into its own
This appliance can be used by children aged from 8
This canopy rangehood is not recommended for
Grease filters must be removed every four weeks
The exhaust from the canopy rangehood must not
Exhaust air must not be discharged into a wall cavity,
• There must be adequate ventilation of the room when
Always cover lit gas burners with pots or pans when
Always switch off gas burners before you remove
Do not leave lit gas burners exposed due to the risk
The hood must always be disconnected from
Failure to install the screws or fixing device in
WARNING
dedicated 220-240V, 50Hz AC electrical outlet.
years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
barbecues and cannot be installed for external use.
(maximum) for cleaning to reduce the risk of fire.
be discharged into any heating flue, which may carry combustion products from other sources. (Fig 1)
unless the cavity is designed for the purpose.
the canopy rangehood is used at the same time as appliances burning gas or other fuels.
canopy rangehood is in use.
pots or pans.
of fire. (Fig 2)
the electricity supply before beginning any maintenance work.
accordance with these instructions may result in electrical hazards.
Fig. 1 Fig. 2
SAFETY
3SAFETY
IMPORTANT SAFETY INSTRUCTIONS (CONTINUED)
Electrical connection
Check that the mains voltage matches with the voltage on the data plate inside the canopy rangehood. Check that the installation complies with standards of local building, gas and electrical authorities. Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or similarly qualified person in order to avoid a hazard.
Safety warnings – for the installer
When installing the cooker hood, make sure you adhere to the minimum and maximum distances from the cooker hood base to the hob surface (refer to page 8).
Exhaust flue installation: The following rules must be strictly followed to obtain optimal air extraction.
Keep exhaust flue short and straight.
Do not reduce the size or restrict exhaust flue. Keep
bends in the exhaust flue to a minimum.
When using flexible flue always install duct with helix
pulled taut to minimise pressure loss.
Failure to observe these basic instructions will
drastically reduce the performance and increase the noise levels of the cooker hood.
Exhaust air must not be discharged into a wall cavity, unless the cavity is designed for that purpose. The exhaust from the cooker hood must not be discharged into any heating flue, which may carry combustion products from other sources.
NOTE: Some installations may require the telescopic exhaust cover to be cut to length. Cut with sharp tin snips or a fine-tooth hack saw blade, taking care not to distort or dent the exhaust cover.
4 SAFETY
PRODUCT DESCRIPTION
WRCG930SB WRCG940SB
1
Upper Flue mounting bracket
2
Telescopic flue cover
3
Lower Flue mounting bracket
4
Lower Flue cover
5
150-120 reducer
6
Exhaust transition duct
7
Hood motor body
8
Glass fixing screws x4
9
Glass canopy
10
Filter
1
2
3
4
5
6
7
8
9
Fig. 3
Additional items required for installation
Fixings required to attach rangehood body and
anti tilt brackets
Fixings required to attach flue cover
Technical specification
Power supply: 240 V 50 Hz. Connects to 10 A power point
Lights: 2 x 4 watt, 240 V LED
10
mounting brackets
Worm drive clamps, duct tape or cable ties
Ducting accessories
MODEL WRCG930SB WRCG940SB
Height 730 mm - 1115mm 745 mm - 1130mm
Width 900mm 900mm
Depth 500mm 500mm
Max absorbed power 338 W 338 W
Lighting 2 x 4W LED (GU10 fitting) 2 x 4W LED (GU10 fitting)
Outlet diameter 150mm 150mm
Electrical connection 220 - 240V, 50Hz 220 - 240V, 50Hz
The manufacturer reserves the right to make technical changes.
5PRODUCT DESCRIPTION
RANGEHOOD DIMENSIONS
WRCG930SB
500
320
280
900
6 DIMENSIONS
Min 730/ Max 1115
576
588 380
Fig. 4
Loading...