ASSEMBLY INSTRUCTIONS FOR INDOOR LIGHT FIXTURE
Congratulations on your Westinghouse purchase. This fixture has been designed to give you
many years of beauty and service. Please email questions and comments to:
info@westinghouselighting.com.
NOTE: Carefully unpack fixture and parts. Make sure all parts are included before
discarding any packing materials (see figure 1).
WARRANTY INFORMATION
This Westinghouse Lighting Fixture is warranted against defects in material and workmanship for a period of Five
Years from purchase date. This warranty is in lieu of all other warranties expressed or implied.
This warranty does not cover acts of nature such as lightening damage, or corrosion and discoloration of components,
nor does it cover damages caused through abuse, improper installation, surges in electric current, or acts of third
parties.
This warranty does not cover broken glass. If fixture is received with broken glass, please call Westinghouse Lighting
for free replacement.
This warranty does not cover costs of removing and re-installing the light fixture.
If this fixture fails for any reason covered by this warranty, simply return the fixture with a copy of the original sales
receipt, freight prepaid and Westinghouse Lighting, at its option, shall repair or replace the fixture or refund the
purchase price.
WARNING ELECTRICAL SHOCK CAN RESULT IN SERIOUS INJURY.
Read and follow instructions exactly as shown. If instructions are unclear, do not proceed.
Contact a qualified electrician. Read all instructions before beginning. Proper wiring is
essential for safe operation of this fixture. When cutting or drilling into walls or ceilings,
do not damage electrical wiring, gas lines, or water lines. If any of the fixture or wiring
compo-nents are damaged, do not install fixture. Return to place of purchase.
For fixtures provided with 75° C or 90° C supply wire warning only. (These warnings are
provided on the U.L. label and on the fixture carton.) Risk of fire. Most dwellings built before
1985 have supply wires rated 60° C. Consult a qualified electrician before installing.
NOTE: For fixture employing a grounded convenience outlet. This fixture employs a grounded
type receptacle and is not intended for connection to a two wire ungrounded source of supply.
Applicable only to portable lamps:
To reduce the risk of electrical shock, all portable lamps have a polarized plug (one blade is
wider than the other). This plug will fit into a polarized outlet only one way. If plug does
not fit, reverse the plug. If it still does not fit, contact a qualified electrician. Never use
with an extension cord unless plug can be fully plugged into the extension cord. Do not
alter the plug.
2
*OUTLET
BOX (C)
GROUND
WIRE
CROSS BAR (B)
*OUTLET BOX
SCREWS (F)
MOUNTING
SCREWS (A)
WIRE CONNECTORS (G)
CAP NUTS (L)
SIDE
HOLE (I)
GREEN
GROUNDING
SCREW (H)
BACK
PLATE (D)
SCREW
NUT (j)
COVER (K)
FIXTURE
BODY(M)
FIGURE 1.
Line art shown may not exactly match the fixture enclosed.
However, the installation instructions do apply to this fixture.
3
*NOT SUPPLIED
MOUNTING AND WIRING INSTRUCTIONS
CAUTION: For fixtures labeled for outdoor and wet location use, provide a water-tight seal between the fixture and
the mounting surface by using silicone or similar caulking.
NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL
specifications.
1. Turn off power at circuit box to avoid possible electric shock.
2. Thread mounting screws (A) into universal mounting plate or cross bar (B) approximately 1/4 inch (see fig. 1).
NOTE: If universal mounting plate or cross bar (B) was preinstalled, remove cap nuts (L) and universal mounting
plate or cross bar (B) from back plate (D), leaving mounting screws (A) in place.
3. Secure universal mounting plate or cross bar (B) to outlet box (E) with outlet box screws (F).
4. Identify color coding of fixture wires (see fig. 2).
5. To connect wires, take black fixture wire (group A from fig. 2) and place evenly against black outlet box wire.
Do not twist wires.
6. Fit wire connector (G from fig. 1) over wires and twist until there is a firm connection. If wire connector (G)
easily comes off, reattach and check again for a firm connection.
7. Repeat steps 5 and 6 with the white (group B from fig. 2) fixture wires and outlet box wires.
8. Partially thread green grounding screw (H) into side hole (I) on universal mounting plate or cross bar (B)
(see fig. 1).
9. Wrap ground wire from fixture around green grounding screw (H), leaving enough excess wire to then
connect ground wire and outlet box wire with wire connector (G) (see step 11).
10. Tighten green grounding screw (H). Do not over tighten.
11. Tuck wires inside outlet box (E) (see fig. 1).
FIXTURE ASSEMBLY INSTRUCTIONS
1. Position back plate (D) over mounting screws (A) and secure with cap nuts (L). (see fig. 1).
2. Remove top cover (K) by removing screw nut (J).
3. Install lamp(s). Do not exceed recommended wattage.
4. Replace top cover (K) over fixture body (M), secure with screw nut (J).
5. Turn power back on at circuit box.
4