DIMENSION AND INSTALLATION GUIDE
510mm
594mm
50mm
(built-in height)
7c_d_ckc
8c_d_ckc
+,&cc
*.&cc
=Wiikffbo
Yedd[Yj_ed
MODELS: GHP16, GHP17, GHP765
cooktop dimensions
gas cooktop
Note: Electrical connection
Requires 240V 10AMP power outlet
building-in cut-out dimensions
minimum distance to
combustible vertical surface
A 148mm
B 154mm
NOTE: All appliances must be installed to Australian Standard AS5601
Walls around cooktop must be
heat resistant for temperatures up to
90oC to a height of 150mm above
the bench top.
These models are supplied with
10Amp plug and lead
2008 Electrolux Home Products Pty Ltd
©
WDIMGHP16/17/765 Current as at Jul 2008
DIMENSION AND INSTALLATION GUIDE
510mm
894mm
50mm
(built-in height)
7c_d_ckc
8c_d_ckc
.)&cc
*.&cc
=Wiikffbo
Yedd[Yj_ed
MODELS: GHP95, GHP795
cooktop dimensions
gas cooktop
Note: Electrical connection
Requires 240V 10AMP power outlet
building-in cut-out dimensions
minimum distance to
combustible vertical surface
A 143mm
B 154mm
NOTE: All appliances must be installed to Australian Standard AS5601
Walls around cooktop must be
heat resistant for temperatures up to
90oC to a height of 150mm above
the bench top.
These models are supplied with
10Amp plug and lead
2008 Electrolux Home Products Pty Ltd
©
WDIMGHP95/795 Current as at Jul 2008
DIMENSION AND INSTALLATION GUIDE
510mm
744mm
50mm
(built-in height)
7c_d_ckc
8c_d_ckc
+,&cc
*.&cc
=Wiikffbo
Yedd[Yj_ed
MODELS: GHP775
cooktop dimensions
gas cooktop
Note: Electrical connection
Requires 240V 10AMP power outlet
building-in cut-out dimensions
minimum distance to
combustible vertical surface
A 183mm
B 154mm
NOTE: All appliances must be installed to Australian Standard AS5601
Walls around cooktop must be
heat resistant for temperatures up to
90oC to a height of 150mm above
the bench top.
These models are supplied with
10Amp plug and lead
2008 Electrolux Home Products Pty Ltd
©
WDIMGHP775 Current as at Jul 2008
DIMENSION AND INSTALLATION GUIDE
610mm
515mm
40mm
(built-in height)
600mm
50mm min
490mm
560mm
Note: Connection type – hardwired
Maximum power load 5.9kW
MODEL: PHN668
cooktop dimensions
electric ceramic cooktop
building-in cut-out dimensions
Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC,
up to 150mm high eg. ceramic tiles
Note: If a barrier is not required, a minimum gap of 30mm is needed under
the cooktop.
Note: If the base of the cooktop can be touched from inside a cupboard or
drawer, a barrier MUST be installed to prevent contact. The material for
the barrier must be capable of sustaining heat up to 70
the barrier is at least 50mm and not more than 75mm below the base
of the cooktop. The barrier is to have ventilation holes evenly spaced
in the one of the following configurations: 25 x 25mm diameter,
15 x 35mm diameter or 6 x 50mm diameter.
o
C. Make sure
2008 Electrolux Home Products Pty Ltd
©
WDIMPHN668 Current as at Jul 2008