Westinghouse 22 SEER, 10 HSPF iQ Drive Technical Literature

TECHNICAL SPECIFICATIONS
FT4BI Series
R-410A, Ultra High Efficiency Heat Pump, 21+ SEER, 12.5+ EER,
9.6 HSPF Residential System 2-3-4 Ton Capacities
The iQ Drive® Heat Pump System features fully variable speed compressor technology and variable speed indoor and outdoor motors. The system provides variable cooling capacity as needed. It operates near the nominal rated capacity at the thermostat set point and modulates as temperature difference between set point and room temperature changes. The system may run at additional 18% capacity to provide rapid cooling. The system has a built-in humidity control that will activate humidier equipment (if supplied), and reduces blower speed if indoor relative humidity is greater than set point (default set at 60%).
WARRANTY
FEATURES and BENEFITS
iQ Drive: Inverter driven Panasonic rotary compressor which provides fully variable operation.
R-410A Refrigerant: Environmentally friendly non- ozone depleting refrigerant.
Designed using galvanized steel: with a polyester urethane coat nish. The 950 hour salt spray nish resists corrosion 50% better than comparable units.
Copper Tube / Aluminum Fin Coils: Both indoor and outdoor coils are designed to optimize heat transfer, minimize size and cost, and increase durability and reliability.
Permanently Lubricated Motor: A heavy duty brushless motor for long lasting reliability and quiet operation. Requires no maintenance and is completely protected from rain and snow.
Compressor Sound Blanket: Engineered to signicantly reduce unwanted compressor noise.
Swept-Wing Fan Blade: Engineered to provide quiet operation. The specic energy absorbing hub is designed to reduce noise while operating through various frequencies.
Louvered Condenser Guard: Durable metal guard protects the coil from yard hazards and extreme weather.
Removable Top Grille Assembly: Allows ease of service from the top without disconnecting fan motor leads.
High Pressure Switch: Protects against abnormally high system pressures. Auto-reset feature prevents nuisance service visits.
Low Pressure Switch: Protects against loss of system refrigerant charge.
Liquid Line Filter Drier: Included with unit, eld installed.
One Piece Top/Orifice: Designed for maximum airow and quiet operation.
Easy Compressor and Control Access: Designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit.
Highest Efficiency with the lowest Sound Levels: Up to 22 SEER with sound ratings of 59-72dB depending upon operating conditions.
This product offers a 10-year all-parts warranty. This product offers a 10 year Quality Pledge to replace
the entire unit, if the unit’s major component (heat exchanger or compressor) fails within the rst 10 years of operation, to the original owner. All split system products must be installed with a matched indoor air handler or indoor coil to qualify.
Consumer product registration required for both 10
year All Parts Warranty and Quality Pledge within a limited period of time after the installation. See current warranty document or visit our consumer web for warranty details.
MODEL IDENTIFICATION CODES
EX: FT4BI-036K
FT - Heat Pump
Design Series
FT 4 B I - 036 K
Product
Identifier
BI = Braze 20-25 SEER
DIMENSIONS AIR CONDITIONER OUTDOOR SECTION
FT4BI 024K 036K 048K
H 37 41 45
W 31 1/4 31 1/4 31 1/4
D 31 1/4 31 1/4 31 1/4
Nominal
Capacity
(000) BTU
Electrical Code K = 208/230-60-1
Air Discharge
Allow Adequate Clearance for Airflow
W
D
H
2
PHYSICAL AND ELECTRICAL SPECIFICATIONS / OUTDOOR UNITS
22 SEER — Ultra High Efficiency — Single Phase
Model Number FT4BI- 024K 036K 048K
Volts-Cycles-Phase (1) 208/230-60-1 208/230-60-1 208/230-60-1
Electrical Data
Condenser Data
Refrigerant suction line O.D. (all length of liquid line are 3/8” O.D.)
Refrigerant charge (R-410A) in ounces for outdoor unit, indoor unit and 15’ lineset.
Weight Net 190 220 225 Approximate (lbs.) Ship 200 230 235
(1) Operating Voltage Range: 187v min. — 253v max. (2) HACR Type Circuit Breakers may be used. (3) Requires Reducers.
Total Amps 13.0 18.0 22.0 Delay Fuse Max. (2) 25 35 45 Min. Circuit Ampacity 16.6 22.9 27.1
2
) 20.3 22.8 25.4
Coil
Area(ft Rows-FPI 1 - 20 1 - 20 1 - 20 Tube Dia 3/8” O.D. 3/8” O.D. 3/8” O.D. Type Brushless DC Brushless DC Brushless DC
Fan Motor
Amps 1.6 1.6 1.6 HP 0.5 0.5 0.5
Fan Blade
Dia-# Blades 24” - 2 24” - 2 24” - 2 SCFM 3200 3400 3600
Compressor Data RLA 11.4 16.4 20.4
0-24 ft. 3/4” 7/8” 7/8” 25-39 ft. 3/4” 7/8” 1 1/8” (3) 40-75 ft. 7/8” (3) 1 1/8” (3) 1 1/8” (3)
171 203 203
NOTE: Refrigerant Tubing Limitations-The compressor manufacturer imposes a maximum equivalent line set length of 100ft. Furthermore, vertical elevation shall not exceed 50 ft.
ACCESSORIES
Controller/Thermostat
920621G
COPPER WIRE SIZE — AWG
(1% Voltage Drop)
Supply Wire Length-Feet Supply Circuit
200 150 100 50
6 8 10 14 15 4 6 8 12 20 4 6 8 10 25 4 4 6 10 30
3 4 6 8 35 3 4 6 8 40 2 3 4 6 45 2 3 4 6 50
Wire Size based on N.E.C. for 60° type copper conductors.
Ampacity
3
SYSTEM COOLING CAPACITIES
22 SEER — Ultra High Efficiency — Single Phase
Outdoor Unit
Model Number FT4BI-
Indoor Unit
Range
Cooling Capacity
@95° OD BTUH
EER @
Nominal
Capacity
SEER
024K B6VMAI24K-B 11,300-26,900 14.6 22 22,800 500-950 036K B6VMAI36K-B 14,200-40,700 13.0 21 35,000 680-1110 048K B6VMAI48K-C 14,300-48,000 12.5 21 44,500 725-1800
Minimum operating ambient temperature is 40°F
NOTE: Each system was operated at its nominal capacity. Indoor conditions were 80F° dry-bulb temperature and 67F° wet-bulb temperature (approx. 51% relative humidity, 95F
SYSTEM H EATING CAPACITIES
22 SEER — Ultra High Efficiency — Single Phase
Outdoor Unit
Model Number FT4BI-
024K B6VMAI24K-B 6,500-24,100 22,400 10 3.9 500-950 036K B6VMAI36K-B 11,300-39,900 34,000 9.6 3.4 680-1110 048K B6VMAI48K-C 11,400-47,800 46,000 10 3.6 725-1800
Minimum operating ambient temperature is 12°F
Indoor Unit
Range
Heating Capacity
@47° OD BTUH
Nominal
Capacity
HSPF
Nominal
Capacity
° outdoor temperature).
Range SCFM
COP @
Nominal
CFM
Capacity
NOTE: Each system was operated at its nominal capacity. Indoor conditions were 70F° dry-bulb temperature and 47F° dry bulb temperature, 43F
° wet bulb outdoor temperature
See current AHRI Directory for certified combinations and ratings.
www.ahridirectory.org