Westinghouse 16 SEER FS4BF Technical Literature

TECHNICAL SPECIFICATIONS
FS4BF-K(B,C) Series
Extra High Efciency Air Conditioner 16 SEER Residential System 2 - 5 Ton Capacity
The FS4BF-K(B,C) Series air conditioners offers exceptional performance. The unit, when combined with our engineered coils or air handlers, offers a line of quality, 16 SEER split system cooling equipment.
FEATURES and BENEFITS
CoreSenseTM Compressor Protection : Control module
actively monitors compressor conditions and will shut the unit down to prevent damage.
Copeland Scroll UltraTechTM Compressor: The Ultra
Tech Compressor operates with 2 stages of cooling capacity to provide superior comfort and efficiency. Copeland's proven and simple design equates to years of comfort and reliability for the homeowner with virtually silent operation.
Durable, Attractive Cabinet: Designed using galvanized steel with a polyester urethane finish. The 950 hour salt spray finish is 1.5 mil thick and resists corrosion 50% better than comparable units.
Composite Base Pan: Absorbs sound and is corrosion resistant. Composite is also stronger and lighter than steel.
Compressor Sound Blanket: Engineered to signicantly reduce unwanted compressor noise.
Swept-Wing Fan Blade: Designed to significantly reduce unwanted noise.
Louvered Condenser Guard: Durable metal guard protects the coil from yard hazards and extreme weather.
Removable Top Grille Assembly: Allows ease of service from the top without disconnecting fan motor leads.
Low Pressure Switch: Loss of charge protection ensures long compressor life. Auto-reset feature prevents nuisance service visits.
High Pressure Switch: Protects against abnormally high system pressures. Auto-reset feature prevents nuisance service visits.
Liquid Line Filter Drier: Included with unit, field installed.
One Piece Top/Orice: Designed for maximum airflow and quiet operation.
Easy Compressor and Control Access: Designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit.
Micro-Channel: All aluminum coils in all models which provides high corrosion resistance.
MODEL IDENTIFICATION CODES
EX: FS4BF-036K(B,C)
FS - Air Conditioner FT - Heat Pump
4 = R-410A
FS 4 B F - 036 K A
Product
Identier
BF = Braze UP TO 16 SEER
(000) BTU
DIMENSIONS AIR CONDITIONER OUTDOOR SECTION
FS4BF 024KB 036KB 048KC 060KC
H 33" 37" 41" 45"
W 22 3/4" 30 3/4" 30 3/4" 30 3/4"
Nominal
Capacity
Revision
Electrical Code K = 208/230-60-1
D 22 3/4" 30 3/4" 30 3/4" 30 3/4"
Air Discharge
Allow Adequate Clearance for Airow
W
D
H
2
PHYSICAL AND ELECTRICAL SPECIFICATIONS / OUTDOOR UNITS
16 SEER Extra High Efciency Single Phase
Model Number FS4BF- 024KB 036KB 048KC 060KC
Volts-Cycles-Phase (1) 208/230-60-1
Electrical Data
Component Data
Refrigerant suction line O.D. NOTE: Liquid line is 3/8” O.D. for entire length.
Approximate Weight (lbs.)
Sound Ratings db
(1) Operating Voltage Range: 187v min. - 253v max. (2) HACR Type Circuit Breakers may be used. (3) Requires 1-1/8” to 7/8” reducer from line to unit. (4) Use of a 3/4” linset will result in approximately 2% loss in capacity. (5) Additional charge for line sets above 15 feet.
Values based on suction line as follows with 3/8” liquid line. a) 3/4” = 0.6 oz. per additional foot. b) 7/8” = 0.7 oz. per additional foot. c) 1 1/8” = 0.8 oz. per additional foot.
Total Amps 12.6 16.5 23.7 31.4 Delay Fuse Max. (2) 25 35 50 60 Min. Circuit Ampacity 15.5 20.3 29.0 38.6
Area 13.3 20.3 22.8 25.4
Coil
Rows-FPI 1-23 1-18 1-18 1-23 Tube Dia MC 3/8” OD Type PSC BLDC
Fan Motor
Amps 0.9 1.3 2.6 2.6 HP 0.13 0.25 0.33 0.33
Compressor Data
RLA 11.6 15.2 21.1 28.8 LRA 58.3 83.0 104.0 152.9 0-24 ft. 3/4” 7/8”(4) 7/8” 7/8" 25-39 ft. 7/8” (3) 1-1/8” (3) 1-1/8” (3) 1-1/8" (3) 40-75 ft. 7/8” (3) 1-1/8” (3) 1-1/8” (3) 1-1/8" (3) Net 144 188 198 186 Ship 151 197 207 195
73 75 76 77
ACCESSORIES - Condensing Unit
Start Assist Kit - 912933
Provides additional starting torque for the compressor motor when operating with low line voltage or high operating temperatures.
Extreme Wind Condition Mounting Kit - 920900
COPPER WIRE SIZE AWG
(1% Voltage Drop)
Supply Wire Length-Feet Supply Circuit
200 150 100 50 Ampacity
6 8 10 14 15 4 6 8 12 20 4 6 8 10 25 4 4 6 10 30 3 4 6 8 35 3 4 6 8 40 2 3 4 6 45 2 3 4 6 50
Wire Size based on N.E.C. for 60° type copper conductors.
3