Westinghouse 16 SEER, 9 HSPF FT4BF Technical Literature

TECHNICAL SPECIFICATIONS
FT4BF-KA/B Series
Extra High Efciency Heat Pump
16 SEER Residential System 2 - 5 Ton Capacity
The FT4BF-KA/B Series of heat pumps offers exceptional performance as well as environmental protection. These models, when matched with our variable speed air handlers or variable speed equipped gas furnaces, offer a line of high quality heat pump systems rated up to 16 SEER and 9.0 HSPF.
FEATURES and BENEFITS
CoreSenseTM Compressor Protection : Control module actively monitors compressor conditions and will shut the unit down to prevent damage.
Copeland Scroll UltraTech
Tech Compressor operates with 2 stages of heating and cooling capacities to provide superior comfort and efficiency. Copeland's proven and simple design equates to years of comfort and reliability for the homeowner with virtually silent operation.
Durable, Attractive Cabinet Designed using galvanized steel with a polyester urethane finish. The 950 hour salt spray finish is 1.5 mil thick and resists corrosion 50% better than comparable units.
Composite Base Pan Absorbs sound and is corrosion resistant. Composite is also stronger and lighter than steel.
Copper Tube / Aluminum Fin Coils Both indoor and outdoor coils are designed to optimize heat transfer, minimize size and cost, and increase durability and reliability.
Demand Defrost Provides additional energy savings in heating by defrosting only when necessary
Louvered Condenser Guard Durable metal guard protects the coil from yard hazards and extreme weather.
Removable Top Grille Assembly Allows ease of service from the top without disconnecting fan motor leads.
Compressor Sound Blanket Engineered to significantly reduce unwanted compressor noise.
Swept-Wing Fan Blade Designed to significantly reduce unwanted noise.
Low Pressure Switch Loss of charge protection ensures long compressor life. Auto-reset feature prevents nuisance service visits.
High Pressure Switch Protects against abnormally high system pressures. Auto-reset feature prevents nuisance service visits.
Liquid Line Filter Drier Included with unit, field installed.
One Piece Top/Orice Designed for maximum airflow and
quiet operation.
Common Suction Service Port This port allows the contractor to read the suction pressure in all modes of operation without removing any panels, saving time and increasing serviceability.
Three Minute Restart Time Delay When the unit shuts down, a three minute delay keeps the unit from restarting, eliminating the highest cause for compressor failure.
Suction Accumulator Protection from liquid flood back and future compressor failures.
Hot Gas Mufer Reduces compressor noise and vibration.
Easy Compressor and Control Access Designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit.
TM
MODEL IDENTIFICATION CODES
EX: FT4BF-036KA
FS - Air Conditioner FT - Heat Pump
4 = Design Series
FT 4 B F - 036 K A
Nominal
Product
Identier
BF = Braze 15 - 17 SEER
Capacity
(000) BTU
DIMENSIONS HEAT PUMP OUTDOOR SECTION
FT4BF 024KB 036KA 048KA 060KA
H 45 1/2 45 1/2 45 1/2 45 1/2
W 31 1/4 31 1/4 31 1/4 31 1/4
D 31 1/4 31 1/4 31 1/4 31 1/4
Revision
Electrical Code K = 208/230-60-1
Air Discharge
Allow Adequate Clearance for Airow
W
D
H
2
PHYSICAL AND ELECTRICAL SPECIFICATIONS / OUTDOOR UNITS
16 SEER Extra High Efciency Single Phase
Model Number FT4BF
Volts-Cycles-Phase (1)
Electrical Data
Condenser Data
Refrigerant suction line O.D.(all length of liquid line are 3/8” O.D.)
Refrigerant charge in ounces for outdoor unit, indoor unit and 15’ lineset Weight
Approximate (lbs.) Sound Ratings db
(1) Operating voltage range: 187V minimum - 253 V maximum. (2) HACR type circuit breakers may be used. (3) Requires 1-1/8 to 7/8" reducer from unit to lineset.
(4) Use of a 3/4" lineset will result in approximately 2% loss in capacity. (5) Additional charge for line sets above 15 feet. Values based on suction line as follows with 3/8” liquid line. a) 3/4” = 0.6 oz per additional foot. b) 7/8” = 0.7 oz per additional foot.
c) 1 1/8” = 0.8 oz per additional foot.
Total Amps Delay Fuse Max. (2) Min. Circuit Ampacity
Coil
Fan Motor
Fan Blade
Compressor Data
Area Rows-FPI Tube Dia Type Speeds Amps HP Dia-# Blades SCFM RLA LRA 0-24 ft. 25-39 ft. 40-75 ft.
Net Ship
024KB 036KA 048KA 060KA
208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1
11.4 17.9 24.0 25.9 20 35 50 50
14.0 22.1 29.3 31.7
25.4 25.4 25.4 25.4
1-20 2-18 2-18 2-18
3/8” O.D. 3/8” O.D. 3/8” O.D. 3/8” O.D.
PSC PSC BLDC BLDC
2 2 2 2
1.3 1.3 2.9 2.9 1/4 1/4 1/3 1/3
24”- 2 24”- 2 24”- 2 24”- 2
3600 4000 4000 4000
10.3 16.6 21.1 23.0 52 82 96 118
3/4” 7/8” (4) 7/8” 7/8” 7/8” 1-1/8” (3) 1-1/8” (3) 1-1/8” (3) 7/8” 1-1/8” (3) 1-1/8” (3) 1-1/8” (3) 211 243 272 272 253 277 277 301 265 289 289 313
75 75 76 78
SYSTEM HEATING AND COOLING CAPACITIES
16 SEER Extra High Efciency Single Phase
With this Coil
Cooling Indoor CFM Heating
Outdoor Unit
Number FT4BF
024KB X26(C,U)-B+MB7(E,V)M 18000 24000 16 036KA X36(C,U)-B+MB7(E,V)M 25000 36000 16 036KA X36(C,U)-C+MB7(E,V)M 25000 36000 16 048KA X48(C,U)-C+MB7(E,V)M 34000 48000 16 060KA X60(C,U)-C+MB7(E,V)M 41000 55000 16
Outdoor Unit
Number FT4BF
024KB X24KB 18000 24000 16 036KA X36KB 25000 36000 16 048KA X48KC 34000 48000 16 060KA X60KC 41000 55000 16
Air handlers and coils used in tables are designed and manufactured by NORDYNE.
See current AHRI Directory for certified combinations and ratings. www.ahridirectory.org
Indoor Unit
Number C6BA/H-
Indoor Uni t
Number B6VMA
Low Speed
Capacity
(Btu/h)
Low Speed
Capacity
(Btu/h)
High Speed
Capacity
(Btu/h) SEER EER
10.5
10.5
10.5
10.5
10.5
With this Air Handler
Cooling Indoor CFM Heating
High Speed
Capacity
(Btu/h) SEER EER
10.5
10.5
10.5
10.5
Low Speed SCFM
640 850 18000 24000 9.0 900 1250 24000 36000 9.0
900 1250 24000 36000 9.0 1140 1700 31000 46000 9.0 1200 1800 37000 52500 8.5
Low Speed SCFM
640 850 18000 24000 9.0
900 1250 24000 36000 9.0 1140 1700 31000 46000 9.0 1200 1800 37000 52500 8.5
High Speed SCFM
High Speed SCFM
Low Speed
Capacity
(Btu/h)
Low Speed
Capacity
(Btu/h)
High Speed
Capacity
(Btu/h) HSPF
High Speed
Capacity
(Btu/h) HSPF
ACCESSORIES - Condensing Unit
Start Assist Kit - 912933
Provides additional starting torque for the compressor motor when operating with low line voltage or high operating temperatures.
Extreme Wind Condition Mounting Kit - 920900
Snow Stand Kit - 920636
3
Loading...