The FT4BF-KA/B Series of heat pumps offers
exceptional performance as well as environmental
protection. These models, when matched with
our variable speed air handlers or variable speed
equipped gas furnaces, offer a line of high quality heat
pump systems rated up to 16 SEER and 9.0 HSPF.
FEATURES and BENEFITS
• CoreSenseTM Compressor Protection : Control module
actively monitors compressor conditions and will shut the
unit down to prevent damage.
• Copeland Scroll UltraTech
Tech Compressor operates with 2 stages of heating and
cooling capacities to provide superior comfort and
efficiency. Copeland's proven and simple design equates
to years of comfort and reliability for the homeowner with
virtually silent operation.
• Durable, Attractive Cabinet – Designed using
galvanized steel with a polyester urethane finish. The 950
hour salt spray finish is 1.5 mil thick and resists corrosion
50% better than comparable units.
• Composite Base Pan – Absorbs sound and is corrosion
resistant. Composite is also stronger and lighter than steel.
• Copper Tube / Aluminum Fin Coils – Both indoor and
outdoor coils are designed to optimize heat transfer, minimize
size and cost, and increase durability and reliability.
• Demand Defrost – Provides additional energy savings in
heating by defrosting only when necessary
• Louvered Condenser Guard – Durable metal guard protects
the coil from yard hazards and extreme weather.
• Removable Top Grille Assembly – Allows ease of service
from the top without disconnecting fan motor leads.
• Compressor Sound Blanket – Engineered to significantly
reduce unwanted compressor noise.
• Swept-Wing Fan Blade – Designed to significantly reduce
unwanted noise.
• Low Pressure Switch – Loss of charge protection ensures
long compressor life. Auto-reset feature prevents nuisance
service visits.
• High Pressure Switch – Protects against abnormally high
system pressures. Auto-reset feature prevents nuisance
service visits.
• Liquid Line Filter Drier – Included with unit, field installed.
• One Piece Top/Orice – Designed for maximum airflow and
quiet operation.
• Common Suction Service Port – This port allows the
contractor to read the suction pressure in all modes of
operation without removing any panels, saving time and
increasing serviceability.
• Three Minute Restart Time Delay – When the unit shuts
down, a three minute delay keeps the unit from restarting,
eliminating the highest cause for compressor failure.
• Suction Accumulator – Protection from liquid flood back
and future compressor failures.
• Hot Gas Mufer – Reduces compressor noise and
vibration.
• Easy Compressor and Control Access – Designed to
make servicing easier for the contractor, access panels are
provided to all controls and the compressor from the side of
the unit.
TM
Compressor – The Ultra
MODEL IDENTIFICATION CODES
EX: FT4BF-036KA
FS - Air Conditioner
FT - Heat Pump
4 = Design Series
FT 4 B F - 036 K A
Nominal
Product
Identier
BF = Braze 15 - 17 SEER
Capacity
(000) BTU
DIMENSIONS
HEAT PUMP OUTDOOR SECTION
FT4BF 024KB 036KA 048KA 060KA
H 45 1/2 45 1/2 45 1/2 45 1/2
W 31 1/4 31 1/4 31 1/4 31 1/4
D 31 1/4 31 1/4 31 1/4 31 1/4
Revision
Electrical Code
K = 208/230-60-1
Air Discharge
Allow Adequate Clearance for Airow
W
D
H
2
PHYSICAL AND ELECTRICAL SPECIFICATIONS / OUTDOOR UNITS
16 SEER — Extra High Efciency — Single Phase
Model Number FT4BF
Volts-Cycles-Phase (1)
Electrical Data
Condenser Data
Refrigerant suction line O.D.(all length of liquid line
are 3/8” O.D.)
Refrigerant charge in ounces for outdoor unit, indoor unit and 15’ lineset
Weight
Approximate (lbs.)
Sound Ratings db
(1) Operating voltage range: 187V minimum - 253 V maximum.
(2) HACR type circuit breakers may be used.
(3) Requires 1-1/8 to 7/8" reducer from unit to lineset.
(4) Use of a 3/4" lineset will result in approximately 2% loss in capacity.
(5) Additional charge for line sets above 15 feet. Values based on suction line as follows with 3/8” liquid line.
a) 3/4” = 0.6 oz per additional foot.
b) 7/8” = 0.7 oz per additional foot.
c) 1 1/8” = 0.8 oz per additional foot.
Total Amps
Delay Fuse Max. (2)
Min. Circuit Ampacity
Coil
Fan Motor
Fan Blade
Compressor Data
Area
Rows-FPI
Tube Dia
Type
Speeds
Amps
HP
Dia-# Blades
SCFM
RLA
LRA
0-24 ft.
25-39 ft.
40-75 ft.
Net
Ship
024KB 036KA 048KA 060KA
208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1
11.4 17.9 24.0 25.9
20 35 50 50
14.0 22.1 29.3 31.7
25.4 25.4 25.4 25.4
1-20 2-18 2-18 2-18
3/8” O.D. 3/8” O.D. 3/8” O.D. 3/8” O.D.
PSC PSC BLDC BLDC
2 2 2 2
1.3 1.3 2.9 2.9
1/4 1/4 1/3 1/3
24”- 2 24”- 2 24”- 2 24”- 2
3600 4000 4000 4000
10.3 16.6 21.1 23.0
52 82 96 118
3/4” 7/8” (4) 7/8” 7/8”
7/8” 1-1/8” (3) 1-1/8” (3) 1-1/8” (3)
7/8” 1-1/8” (3) 1-1/8” (3) 1-1/8” (3)
211 243 272 272
253 277 277 301
265 289 289 313
75 75 76 78
SYSTEM HEATING AND COOLING CAPACITIES
16 SEER — Extra High Efciency — Single Phase
With this Coil
Cooling Indoor CFM Heating
Outdoor Unit
Number FT4BF
024KB X26(C,U)-B+MB7(E,V)M 18000 24000 16
036KA X36(C,U)-B+MB7(E,V)M 25000 36000 16
036KA X36(C,U)-C+MB7(E,V)M 25000 36000 16
048KA X48(C,U)-C+MB7(E,V)M 34000 48000 16
060KA X60(C,U)-C+MB7(E,V)M 41000 55000 16
Outdoor Unit
Number FT4BF
024KB X24KB 18000 24000 16
036KA X36KB 25000 36000 16
048KA X48KC 34000 48000 16
060KA X60KC 41000 55000 16
Air handlers and coils used in tables are designed and manufactured by NORDYNE.
See current AHRI Directory for certified combinations and ratings.
www.ahridirectory.org
Indoor Unit
Number C6BA/H-
Indoor Uni t
Number B6VMA
Low Speed
Capacity
(Btu/h)
Low Speed
Capacity
(Btu/h)
High Speed
Capacity
(Btu/h) SEER EER
10.5
10.5
10.5
10.5
10.5
With this Air Handler
Cooling Indoor CFM Heating
High Speed
Capacity
(Btu/h) SEER EER
10.5
10.5
10.5
10.5
Low
Speed
SCFM
640 850 18000 24000 9.0
900 1250 24000 36000 9.0
900 1250 24000 36000 9.0
1140 1700 31000 46000 9.0
1200 1800 37000 52500 8.5
Low
Speed
SCFM
640 850 18000 24000 9.0
900 1250 24000 36000 9.0
1140 1700 31000 46000 9.0
1200 1800 37000 52500 8.5
High
Speed
SCFM
High
Speed
SCFM
Low Speed
Capacity
(Btu/h)
Low Speed
Capacity
(Btu/h)
High Speed
Capacity
(Btu/h) HSPF
High Speed
Capacity
(Btu/h) HSPF
ACCESSORIES - Condensing Unit
Start Assist Kit - 912933
Provides additional starting torque for the compressor motor when operating with low line voltage or high operating temperatures.
Extreme Wind Condition Mounting Kit - 920900
Snow Stand Kit - 920636
3