Westinghouse 16 SEER, 9 HSPF ET4BF Technical Literature

TECHNICAL SPECIFICATIONS
ET4BF-KA/B Series
Extra High Efciency Heat Pump
16 SEER Residential System 2 - 5 Ton Capacity
The ET4BF-KA/B Series of heat pumps offers exceptional performance as well as environmental protection. These models, when matched with our variable speed air handlers or variable speed equipped gas furnaces, offer a line of high quality heat pump systems rated up to 16 SEER and 9.0 HSPF.
FEATURES and BENEFITS
Copeland Scroll UltraTech
Tech Compressor operates with 2 stages of heating and cooling capacities to provide superior comfort and efficiency. Copeland's proven and simple design equates to years of comfort and reliability for the homeowner with virtually silent operation.
Durable, Attractive Cabinet Designed using galvanized steel with a polyester urethane finish. The 950 hour salt spray finish is 1.5 mil thick and resists corrosion 50% better than comparable units.
Composite Base Pan Absorbs sound and is corrosion resistant. Composite is also stronger and lighter than steel.
Copper Tube / Aluminum Fin Coils Both indoor and outdoor coils are designed to optimize heat transfer, mini- mize size and cost, and increase durability and reliability.
Demand Defrost Provides additional energy savings in heating by defrosting only when necessary
Louvered Condenser Guard Durable metal guard protects the coil from yard hazards and extreme weather.
Removable Top Grille Assembly Allows ease of ser vice from the top without disconnecting fan motor leads.
Low Pressure Switch Loss of charge protection en- sures long compressor life. Auto-reset feature prevents nuisance service visits.
High Pressure Switch Protects against abnormally high system pressures. Auto-reset feature prevents nuisance service visits.
Liquid Line Filter Drier Included with unit, field installed.
One Piece Top/Orice Designed for maximum airflow and quiet operation.
Common Suction Service Port This port allows the contractor to read the suction pressure in all modes of operation without removing any panels, saving time and increasing serviceability.
Three Minute Restart Time Delay When the unit shuts down, a three minute delay keeps the unit from restarting, eliminating the highest cause for compressor failure.
Suction Accumulator Protection from liquid flood back and future compressor failures.
Hot Gas Mufer Reduces compressor noise and vibration.
Easy Compressor and Control Access Designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit.
TM
Compressor The Ultra
MODEL IDENTIFICATION CODES
EX: ET4BF-036KA
ES - Air Conditioner ET - Heat Pump
Design Series
ET 4 B F - 036 K A
Nominal
Product
Identier
BF = Braze 15 - 17 SEER
Capacity
(000) BTU
DIMENSIONS HEAT PUMP OUTDOOR SECTION
ET4BF 024KB 036KA 048KA 060KA
H 43 1/2 43 1/2 43 1/2 43 1/2
W 31 31 31 31
D 31 31 31 31
Revision
Electrical Code
K = 208/230-60-1
Air Discharge
Allow Adequate Clearance for Airow
W
D
H
2
PHYSICAL AND ELECTRICAL SPECIFICATIONS / OUTDOOR UNITS
16 SEER Extra High Efciency Single Phase
Model Number ET4BF
Volts-Cycles-Phase (1)
Electrical Data
Condenser Data
Refrigerant suction line O.D.(all length of liquid line are 3/8” O.D.)
Refrigerant charge in ounces for outdoor unit, indoor unit and 15’ lineset. (5)
Weight Approximate (lbs.)
Sound Ratings db
Total Amps
Delay Fuse Max. (2)
Min. Circuit Ampacity
Coil
Fan Motor
Fan Blade
Compresser Data
Area
Rows-FPI
Tube Dia
Type
Speeds
Amps
HP
Dia-# Blades
SCFM
RLA
LRA
0-24 ft.
25-39 ft.
40-75 ft.
Net
Ship
024KB 036KA 048KA 060KA
208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1
11.4 17.9 24.0 25.9
20 35 50 50
14.0 22.1 29.3 31.7
25.4 25.4 25.4 25.4
1-20 2-18 2-18 2-18
3/8” O.D. 3/8” O.D. 3/8” O.D. 3/8” O.D.
PSC PSC BLDC BLDC
2 2 2 2
1.3 1.3 2.9 2.9
1/4 1/4 1/3 1/3
24”- 2 24”- 2 24”- 2 24”- 2
3600 4000 4000 4000
10.3 16.6 21.1 23.0
52 82 96 118
3/4” 7/8” (4) 7/8” 7/8”
7/8” 1-1/8” (3) 1-1/8” (3) 1-1/8” (3)
7/8” 1-1/8” (3) 1-1/8” (3) 1-1/8” (3)
211 243 272 272
253 277 277 301
265 289 289 313
75 76 76 78
(1) Operating voltage range: 187V minimum - 253 V maximum. (2) HACR type circuit breakers may be used. (3) Requires 1-1/8 to 7/8" reducer from unit to lineset. (4) Use of a 3/4" lineset will result in approximately 2% loss in capacity. (5) Additional charge for line sets above 15 feet. Values based on suction line as follows with 3/8” liquid line. a) 3/4” = 0.6 oz. per additional foot. b) 7/8” = 0.7oz. per additional foot. c) 1 1/8” = 0.8 oz. per additional foot.
ACCESSORIES - Condensing Unit
Start Assist Kit - 912933
Provides additional starting torque for the compressor motor when operating with low line voltage or high operat- ing temperatures.
Extreme Wind Condition Mounting Kit - 920900
Snow Stand Kit - 920636