TECHNICAL
SPECIFICATIONS
Q6SE Series
Single Packaged Heat Pump,
Single Phase
Q6SE-14 SEER, 8.0 HSPF
2 - 5 Ton Units
Cooling: 23,000 to 58,000 Btuh
Heating: 22,800 to 59,000 Btuh
The Q6 Series single packaged heat pumps are high
efficiency self contained cooling and heating units that
can be installed on a roof or on a slab. The convertible
unit design makes installations simple in all applications.
Units are ETL and ETLc listed.
FEATURES and BENEFITS
• Copeland Compressor: State of the art scroll compressor
is standard equipment.
• Quiet Operation and Low Vibration: Swept-wing fan
blade combined with custom Venturi condenser fan.
• Wire guard coated with Earth Friendly Epoxy and
plastic mesh hail guard: A guard that will never rust
and protects the units coil from being damaged.
• Copper Tube / Aluminum Fin Coils: Both indoor and
outdoor coils are designed to optimize heat transfer,
minimize size and cost, and increase durability and
reliability.
• Designed using Galvanized Steel: with a polyester
urethane coat finish. The 950 hour salt spray finish is 1.5
mil thick and resists corrosion 50% better than comparable
units.
• Permanently Lubricated Condenser Motor: A heavy
duty PSC motor for long lasting reliability and quiet
operation. Requires no maintenance and is completely
protected from rain and snow.
• Thermostatic Expansion Valves: Factory installed
externally equalized thermostatic expansion valves
provides precise refrigerant control under varying load
conditions.
• Hi Pressure Switch: Ensures long compressor life.
• Externally Accessible Service Ports: Quick access to
refrigeration system.
• Liquid Line Filter Driers: Factory installed at a convenient
location for service.
• Suction Accumulator: Protection from liquid flood back
and future compressor failures.
• Low voltage Transformer: Includes 3 Amp fuse to protect
low voltage circuit.
• Corrosion-Resistant Drain Pan: Quickly drains away
evaporator condensate.
• Energy Efficient: Brushless DC (ECM) Blower Motor.
• Demand Defrost Standard: Provides additional energy
savings in heating by defrosting only when necessary.
• Five Minute Restart Time Delay: When the unit shuts
down, a 5 minute delay keeps the unit from restarting,
eliminating the highest cause for compressor failure.
• Heavy-Gauge, Full Perimeter Base Rails: Facilitates
forklift handling and curb mounting.
• Convertible Air Delivery: Horizontal or downflow to
accommodate rooftop or horizontal applications.
• Easy Compressor and Control Access: Designed to
make servicing easier for the contractor, access panels
are provided to all controls and the compressor from the
side of the unit.
• Easy access: to the evaporator coil for cleaning and
general maintenance.
• Removable Top Grille Assembly: Allows ease of service
to the fan motor.
• Duct Flanges: reduce installation costs.
• Optional Electric Heat: Field installed 5 – 20 KW.
• Proven, Industry Standard Components: Easier service
and availability.
24.9
13.5
16
12
13.3
13.5
16
12
CG
A
47.5
.75 NPT Female
Drain Connector
B
DOWNFLOW
SUPPLY DUCT
OPENING
DOWNFLOW
RETURN DUCT
OPENING
23.5
Heat Pump
Packaged Unit
MODEL IDENTIFICATION CODE
Q 6 S E - X 24 K
Series
Square Duct
E = 14 SEER
R-410A
TXV
DIMENSIONS (in inches)
Electrical Code
K = 208/230-60-1
Nominal Capacity
x 1000 Btu
2
Model
Number
Q6SE
Unit
Weight
(lbs)
Shipping
Weight
(lbs)
X24 440 453 28.0 25.5 39.0 35.3
X30 450 463 28.0 26.0 39.0 35.3
X36 460 473 28.0 25.5 39.0 35.3
X42 560 573 29.5 26.0 43.0 39.3
Top View
Center of Gravity
A B
Height (in inches)
C
with base rails without base rails
X48 570 583 29.5 26.0 43.0 39.3
X60 580 593 29.5 26.0 43.0 39.3
DIMENSIONS (Continued)
1.25 dia. Power Entry
1.75 dia. Power Entry (Capped)
0.88 dia. Control Wiring Entry
23.6
27.2
30.0
1.8
4.00
5.0
SUPPLY
C
14.7
13.5
11.75 22.75
16.0
Side View
8
13.45
55.8
RETURN
16.0
4.0
CONDENSING
COIL
13.5
Back (Duct) View
3
SPECIFICATIONS
Q6SE
Model Number
Performance
Capacity-Heating BTUH 22,000 26,800 33,200 42,000 45,500 59,000
Efficiency-HSPF 8.0 8.0 8.0 8.0 8.0 8.0
Capacity-Cooling BTUH 23,000 28,000 34,800 42,000 48,000 58,500
Efficiency-Seer 14.0 14.0 14.0 14.0 14.0 14.0
EER (Btuh/watt) 11.0 11.0 11.0 11.0 11.0 11.0
Electric Rating-60 Hz
Phase 1 1 1 1 1 1
Operating Voltage Range 187-253 187-253 187-253 187-253 187-253 187-253
Min. Circuit Ampacity 22.7 24.4 28.5 32.9 37.2 43.5
Field Wire Size - AWG 10 10 10 8 8 6
Total Unit - Amps 19.1 20.5 23.9 27.4 31.2 36.2
Compressor Data
Volts 208-230 208-230 208-230 208-230 208-230 208-230
Rated Load Amps 14.3 15.7 18.6 22.1 24.3 29.3
Lock Rotor Amps 58.3 73 79 109 117 134
X24 X30 X36 X42 X48 X60
Indoor Blower
Type Fixed Torque Fixed Torque Fixed Torque Fixed Torque Fixed Torque Fixed Torque
Motor HP 1/2 1/2 1/2 1/2 3/4 3/4
Motor - Amps 3.8 3.8 3.8 3.8 5.4 5.4
Outdoor Fan
Motor - HP / RPM 1/5 - 825 1/5 - 825 1/4 - 1100 1/4 - 1100 1/4 - 1100 1/4 - 1100
Motor - Amps 1.0 1.0 1.46 1.46 1.46 1.46
Fan Diameter / CFM 20 / 3600 20 / 3600 24 / 3800 20 / 3800 24 / 3800 24 / 4000
R-410A Charge - Oz 128 126.4 115 232 272 243
Net Weight lbs. 440 450 460 560 570 580
Shipping Weight lbs. 453 463 473 573 583 593
Sound Rating
73 73 78 78 78
78
4