Westermo Teleindustri AB
©
12-port Ethernet M12 switch
with Power over Ethernet
www.westermo.com
Page 2
Software tools
Related software tools are available in the folder software tools under technical support on the Westermo website.
License Information
This device contains public available software which is under the GPL license. For more information see legal.pdf included with all firmware releases. This product includes software developed by the OpenSSL Project for use in the
OpenSSL Toolkit. http://www.openssl.org
Legal information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
http://www.westermo.com
2
6641-2252
Page 3
Safety
!
!
Before installation:
Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from all power supply. Ensure compliance to national installation regulations. This unit relies on convection heating. Make sure that it is installed so that the ambient temperature is within the specified temperature range, e.g. by avoiding obstruction of the airflow around the unit. Also check chapter CEN/TS 45545-2 mounting notes.
Before mounting, using or removing this unit:
Prevent access to hazardous voltage by disconnecting the unit from all power supply.
WARNING
Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.
Before powering-up, a protective earthing conductor must be connected to the protective earthing terminal and have a cross-sectional area of at least 1.5 mm². Note that this unit can be connected to two different power sources.
When this unit is operated at an ambient temperature above +60°C (+140°F), the External Surface of Equipment may exceed Touch Temperature Limit according to EN/IEC/UL 60950-1. To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
6641-2252
3
Page 4
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfill the warranty obligations:
Do not attempt to dissassemble the unit. There are not any user serviceable
parts inside.
Do not drop, knock or shake the unit. Rough handling above the specification
may cause damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the
unit.
Do not expose the unit to any kind of liquid (water, beverages, paint etc),
unless all connectors are connected or fitted with protective caps (delivered with the unit), tightened to the specified torque. Connected cables must have the appropriate ingress protection code.
Do not use or store the unit in dusty or dirty areas, unless all connectors and
the ventilation membrane are sufficiently protected.
Do not cover or bring mechanical force to the ventilation membrane on the
back of the unit.
If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
4
6641-2252
Page 5
Agency approvals and standards compliance
Type Approval / Compliance
EMC EN 61000-6-1, Immunity residential environments
EN 61000-6-2, Immunity industrial environments
EN 61000-6-4, Emission industrial environments
EN 50121-3-2, Railway applications – Rolling stock – apparatus
EN 50121-4 / IEC 62236-4, Railway signaling and telecommunications apparatus
FCC part 15 Class A
Safety EN 60950-1, IT equipment
Environmental EN 61373
FCC Part 15.105 Notice:
Railway applications – Rolling stock equipment. Shock and vibration tests
IEEE 1478 Environmental conditions for transit rail car electronic equipment
EN 50124-1 Railway applications – Insulation coordination
EN 50155 Railway applications – Electronic equipment used on rolling stock
CEN/TS 45545-2 Fire safety standard
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
6641-2252
5
Page 6
Declaration of Conformity
Westermo Teleindustri AB
Declaration of conformity
The manufacturer
Herewith declares that the product(s)
Type of product Model Art no 12-port managed Gig Ethernet M12 PoE Switch
is in conformity with the following EC directive(s).
No Short name
2004/108/EC Electromagnetic Compatibility (EMC) 2006/95/EC Low Voltage (LVD) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic
References of standards applied for this EC declaration of conformity. No Title Issue
EN 50121-3-2 Railway applications – Electromagnetic compatibility – Rolling stock -
EN 50121-4 Railway applications – Electromagnetic compatibility – Emission and immunity
EN 61000-6-1 Electromagnetic compatibility - Generic standards - Immunity for residential,
EN 61000-6-2 Electromagnetic compatibility - Generic standards - Immunity for industrial
EN 61000-6-4 Electromagnetic compatibility - Generic standards - Emission standard for
EN 60950-1 Information technology equipment – Safety – General require ments 2006
EN 50581 Technical documentation for the assessment of electrical and electronic products
The last two digits of the year in which the CE marking was affixed: 15
Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden
Viper-112-T3G-P8, Viper-212­T3G-P8
equipment (RoHS)
Apparatus
of the signaling and telecommunications apparatus
commercial and light-industrial environments
environments
industrial environments
with respect to the restriction of hazardous substances
3641-0570, 3641­0595
2006
2006
2007
2005
2007 +A1:2011
+A11:2009 +A1:2010 +A12:2011 2012
Telefax
Postgiro
Bankgiro Corp. identity number Registered office
Pierre Öberg Technical Manager
th
June 2015
24
Org.nr/ Postadress/Postal address
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
Tel.
6
6641-2252
Page 7
Declaration of Conformity
Westermo Teleindustri AB
Declaration of conformity
The manufacturer
Herewith declares that the product(s)
Type of product Model Art no 12-port managed Ethernet M12 PoE Switch
is in conformity with the following EC directive(s).
No Short name
2004/108/EC Electromagnetic Compatibility (EMC) 2006/95/EC Low Voltage (LVD) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic
References of standards applied for this EC declaration of conformity. No Title Issue
EN 50121-3-2 Railway applications – Electromagnetic compatibility – Rolling stock -
EN 50121-4 Railway applications – Electromagnetic compatibility – Emission and immunity
EN 61000-6-1 Electromagnetic compatibility - Generic standards - Immunity for residential,
EN 61000-6-2 Electromagnetic compatibility - Generic standards - Immunit y for industrial
EN 61000-6-4 Electromagnetic compatibility - Generic standards - Emission standard for
EN 60950-1 Information technology equipment – Safety – General requirements 2006
EN 50581 Technical documentation for the assessment of electrical and electronic products
The last two digits of the year in which the CE marking was affixed: 15
Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden
Viper-112-P8, Viper-212-P8 3641-0580, -0590
equipment (RoHS)
Apparatus
of the signaling and telecommunications apparatus
commercial and light-industrial environments
environments
industrial environments
with respect to the restriction of hazardous substances
2015
2006
2007
2005
2007 +A1:2011
+A11:2009 +A1:2010 +A12:2011 2012
Telefax
Postgiro
Bankgiro Corp. identity number Registered office
Pierre Öberg Technical Manager
th
24
June 2015
Org.nr/ Postadress/Postal address
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
Tel.
6641-2252
7
Page 8
Type tests and environmental conditions
Environmental phenomena Basic standard Description Test levels
ESD EN 61000-4-2 Enclosure Contact: ±6 kV Air: ±8 kV Fast transients EN 61000-4-4 Power port ±4 kV
Surge EN 61000-4-5 Power port L-E: ±0.5 kV, 12 Ω, 9 μF, 1.2/50 μs
Power frequency magnetic field EN 61000-4-8 Enclosure 300 A/m; 0, 16.7, 50, 60 Hz Pulsed magnetic field EN 61000-4-9 Enclosure 300 A/m Radiated RF immunity EN 61000-4-3 Enclosure 20 V/m @ (80 MHz – 2.7 GHz)
Conducted RF immunity EN 61000-4-6 Power port 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Radiated RF emission CISPR 16-2-3 Enclosure Class A
Conducted RF emission CISPR 16-2-1 Power port Class A
Dielectric strength EN 60950-1 Power port to all
Environmental
Temperatures Operating –40 to +70°C (–40 to +158°F)**
Humidity Operating 5 to 95 % relative humidity
Altitude Operating 2 000 m / 70 kPa Service life Operating 15 years @ 25°C (+77°F) MTBF Viper-x12-P8:
Vibration IEC 60068-64
Shock IEC 60068-2-27 Operating 10 g, 30 ms, 20 g, 11 ms, 100 g, 6 ms Enclosure EN 60950-1 Zinc (front)
Dimension W x H x D With connectors
Weight 1.7 kg Degree of protection EN 60529 Enclosure IP67*** Cooling Convection
* Only Viper-x12-P8 according to EN50121-3: 2015 ** Refer to “Safety” section *** Provided all connectors are connected with IP67 cabling or fitted with protective caps (delivered with the unit), tightened to the specified torque
ANSI C63.4 (FCC Part 15)
(random)
Ethernet ports ±2 kV Earth port ±1 kV
L-L: ±0.5 kV, 2Ω, 18 μF, 1.2/50 μs L-E: ±2 kV, 42 Ω, 0.5 μF, 1.2/50 μs L-L: ±2 kV, 42Ω, 0.5 μF, 1.2/50 μs L-E: ±8.4 kV, 100 Ω, 0.05/0.1 μs
Ethernet ports L-E: ±2 kV, 2 Ω
Ethernet ports 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz Earth port 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Ethernet ports Class B
other ports Fast Ethernet ports to
all other ports (not between PoE ports)
Gigabit Ethernet ports to all other ports
Storage and transport –50 to +85°C (–58 to +185°F)
Storage and transport 5 to 95 % relative humidity
448 000 h Viper-x12-P8-T3G:
403 000 h Operating 5 – 20 Hz, 0.0405 g²/Hz
Aluminum (rear)
L-L: ±8.4 kV, 100 Ω, 0.05/0.1 μs
10 V/m @ (2.7 Ghz – 6 GHz)* 1 kHz sine, 80% AM
Class A
1.5 kV ACrms, 50 Hz, 1 min
1.5 kV ACrms, 50 Hz, 1 min
500 V ACrms, 50 Hz, 1 min
MIL-C217F2, GB, 25°C (+77°F)
20 – 150 Hz, –6 dB / oct 5h, 1.14 grms
Fire enclosure
See "Dimensions" chapter for details
8
6641-2252
Page 9
Description
Designed for harsh industrial environments
The Viper-12-PoE series is a series of managed rugged Ethernet switches with Power over Ethernet, designed for applications with severe operating conditions and extreme environments.
With an ultra robust design, sealed to IP67 and vibration resistant to and exceeding on-board rail standards these units are ideal for situations where mechanical stress, moisture, condensation, dirt or continuous vibrations could adversely affect the function of standard Ethernet switches. Fully approved for onboard rolling stock, these units can be deployed in e.g. trains, trams, busses, mining trucks, army vehicles and drilling rigs.
Features for complete network management
Our unique FRNT technology is the fastest and most robust protocol on the market to re-configure a large network in the event of any link or hardware failure. The Viper­12-PoE series also supports STP/RSTP in case of need for standard protocol. IGMPv2/ v3 with stop filter and the unique Westermo protocol ’Fast Reconnect’ allows a video stream to reconfigure very fast. Advanced functionality for VLANs with support for up to 64 virtual networks, combined with real-time properties is implemented in the switch in order to achieve determinism for real time critical applications.
Made easy and secure configuration
You can safely access your switch from anywhere in the network, or directly to the product via a console port. The HTTPS secured web configuration interface has been designed ’Made Easy’, setting up a redundant ring or a VLAN is just a few clicks away. For more advanced configuration, you will find an SSH encrypted industry standard CLI which allows extremely detailed settings. For safe handling and MIB readout the switch is also equipped with SNMPv3.
Product models There are four different models of the Viper-12-PoE series: 3641-0580 Viper-112-P8 managed switch with Layer 2 SW functions. 3641-0590 Viper-212-P8 managed switch with Layer 3 SW functions. 3641-0570 Viper-112-T3G-P8 managed switch with Layer 2 SW functions and three GigE ports. 3641-0595 Viper-212-T3G-P8 managed switch with Layer 3 SW functions and three GigE ports.
6641-2252
9
Page 10
Interface specifications
DC, Power port
Rated voltage 48 to 110 VDC Operating voltage 33.6 to 143 VDC (28.8 to 154 VDC for 100 ms) Rated current Viper-x12-P8: Max 1.7 A @ 48V
Viper-x12-T3G-P8: Max 1.8 A @ 48V
Rated frequency DC Inrush current, I²t 21 mA²s @ 48 V
68 mA²s @ 110 V
Startup current* Max 1.8 A @ 48 V
Max 0.8 A @ 110 V Polarity Reverse polarity protected Redundant power input Yes Isolation to 1500 VAC rms to all other Connection 4 pin male M12 A-coded connector, use Westermo cable
3146-1106 for 1.5 m
3146-1107 for 5 m Connector size M12, recommended cable area 0.5 mm² recommended
(minimum 0.25 mm²), cable dimensions depend on choice
of M12 connector
* External supply current capability for proper start-up
X1-X12 Ethernet ports*
Electrical specification IEEE std 802.3. 2005 Edition Data rate 10 Mbit/s, 100 Mbit/s, manual or auto Duplex Full or half, manual or auto Circuit type Viper-x12-P8: X1-X12: TNV-1
Viper-x12-T3G-P8: X1-X3, X5-X7, X9-X11: TNV-1
X4, X8, X12: SELV Transmission range Up to 150 m with CAT5e cable or better
(non PoE ports only) Isolation to Other Ethernet ports, 1500 VAC rms (not between PoE ports)
USB and CON, 1500 VAC rms
DC, 1500 VAC rms Connection 4-pin M12 D-code, auto MDI/MDI-X, use e g Westermo cable
3146-1100 M12-M12 – 1 m
3146-1101 M12-M12 – 5 m
3146-1103 RJ45-M12 – 1 m
3146-1104 RJ45-M12 – 5 m Shielded cable Not required, but recommended in severe electromagnetic
environments Conductive housing Yes FRNT reconfiguration time Typically below 20 ms Number of ports 12
* X1-X3, X5-X7, X9-X11 on Viper-x12-T3G-P8
Max 0.8 A @ 110 V
Max. 0.8 A @ 110 V
10
6641-2252
Page 11
X1-X3, X5-X7, X9-X10, PoE ports (additional data)
Electrical specification IEEE std 802.3af, 2003 edition, IEEE std 802.3at, 2009 edition
Transmission range Up to 100 m with CAT5e cable or better
Output voltage 54 VDC, ±5%
Output power* Max 30.8 W on one port
Max 61.6 W in total on all ports
* Note! As delivered by Power Sourcing Equipment, i e the Viper-12-PoE switch. Power available at Powered Device is depending on cable resistance. Note that PoE ports will not deliver any power for a certain time when a 10 ms interruption occurs on the power input. A suggested workaround is to connect a UPS to the secondary power input.
X4, X8, X12 Gigabit Ethernet ports
Data rate 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto*
Connection 8-pin M12
Transmission range Up to 100 m with CAT5e cable or better
FRNT reconfiguration time Typically below 400 ms
* Note! Full wirespeed (1000 Mbit/s) is not possible between port X4 and the other Gigabit ports due to hardware limitations.
USB, USB port
Electrical specification USB 2.0 host interface
Data rate Up to 480 Mbit/s (high-speed mode)
Maximum supply current 500 mA
Circuit type SELV
Isolation to Ethernet ports, 1500 VAC rms
DC, 1500 VAC rms No isolation to CON
Connection 5-pin M12 female A-code, use Westermo USB plug 3641-0190
CON, Console port
Electrical specification RS-232
Data rate 115.2 kbit/s
Data format 8 data bits, no parity, 1 stop bit, no flow control
Circuit type SELV
Isolation to Ethernet ports, 1500 VAC rms
DC, 1500 VAC rms No isolation to USB
Connection 5-pin M12 female B-code, use Westermo cable 1211-2215
6641-2252
11
Page 12
Location of interface ports and LED’s Viper-112-P8 and Viper-212-P8
LED indicators
(for details see page 13)
ON
USB
RSTP FRNT
CON
DC
X1
X2
X3
X4
Ethernet connection TX (X1 – X12)
(for details see page 8 and 11)
PoE
X9
X5
X6
X10
X11
X7
X8
X12
Earth connection
Power connection
for details see page 8 and 11)
Location of interface ports and LED’s Viper-112-T3G-P8 and Viper-212-T3G-P8
LED indicators
(for details see page 13)
Earth connection
Power connection
for details see page 8 and 11)
Ethernet connection TX (X1 – X12)
(for details see page 8 and 11)
RING
Connect between these ports (X8, X12) to get maximum performance in a ring topology
12
6641-2252
Page 13
Viper-112-P8 / Viper-212-P8
Viper-112-T3G-P8 / Viper-212-T3G-P8
(X1-X12 on Viper-x12-P8, X1-X3, X5-X7, X9-X11 on Viper-x12-T3G-P8)
Pin number Signal
Pin number Signal
Viper-12-PoE supports redundant power connection. The positive inputs are +DC1 and +DC2, the negative input for both supplies are –COM.
Pin number Signal
Pin number Signal
Ethernet connection
No 1 TD+ No 2 RX+ No 3 TX– No 4 RD–
Housing Shield
Power connection
No 1 +DC1 No 2 +DC2 No 3 -COM No 4 -COM
USB
No 1 DN No 2 VBUS No 3 NC No 4 DP No 5 GND
CON
No 1 NC No 2 TX No 3 RX No 4 NC No 5 GND
2 1
3 4
6641-2252
Viper-112-T3G-P8 / Viper-212-T3G-P8
X4, X8, X12
Pin number Signal
1 DA + 2 DA– 3 DB+ 4 DB– 5 DD+ 6 DD– 7 DC– 8 DC+
8
1
7
6
2
3
45
13
Page 14
Connection to console port
The console port can be used to connect to the CLI (Command Line Interface).
The following steps needs to be taken
1. Connect the serial diagnostic cable (use Westermo cable 1211-2215 to the console port).
2. Connect cable to your computer serial port.
3. Use a terminal emulator and connect with correct speed and format (115200, 8N1) to the assigned port.
For more information about the CLI, see the WeOS management guide.
Connection to USB port
The USB port can be used to copy configuration and log files to/from the switch.
The following steps needs to be taken
1. Connect the USB plug (use Westermo USB plug 3641-0190) to the USB port.
2. Access the switch CLI (via console cable or SSH)
3. Use the CLI ''copy'' command to copy files between the USB plug and the switch.
For more information about the CLI, see the WeOS management guide.
14
6641-2252
Page 15
LED Indicators
LED Status Description
ON OFF Unit has no power.
GREEN All OK, no alarm condition.
RED Alarm condition, or until unit
BLINK Location indicator ("Here I
DC OFF Unit has no power.
GREEN Power OK on DC1 and DC1.
RED Power failure on DC1 or DC2.
FRNT OFF FRNT disabled.
GREEN FRNT OK.
RED FRNT Error.
BLINK Unit configured as FRNT Focal
RSTP OFF RSTP disabled.
GREEN RSTP enabled.
BLINK Unit elected as RSTP/STP root
X1
OFF No Link.
to
GREEN Link established.
X12
GREEN FLASH
YELLOW Port alarm and no link. Or if
PoE OFF Port does not consume PoE
GREEN Port consumes PoE Power
has started up. (Alarm conditions are configurable, see ''WeOS Management Guide'').
am!"). Activated when connected to IPConfig Tool, or when configuring the unit via Web or CLI.
Point.
switch.
Data traffic indication.
FRNT, RSTP or Link Aggregation mode, port is blocked.
power
ON
RSTP FRNT
DC
X1
USB
X2
X3
CON
X4
PoE
X9
X5
X6
X10
X11
X7
X8
X12
6641-2252
15
Page 16
Wall mounting
There are four 6 mm bore holes intended for mounting the unit. The unit can be mounted vertical or horizontal. Use four M5 screws with 12 mm washer on a flat and stable surface.
ON
RSTP FRNT
DC
PoE
X1
USB
X2
X3
CON
X4
X9
X5
X10
X6
X11
X7
X8
X12
Connection of cables
Recommended tightening torque for the M12 connectors: 0.6 Nm. Note that unused connectors must be covered by a protective cap (delivered with the
unit), tightened to the specified torque, in order to fulfill the specified ingress protection code.
Removal
Disconnect all cables and unscrew the unit from the wall. Time For Replacement < 15 minutes
Cooling
This unit uses convection cooling. Avoid obstructing the airflow around the unit. Spacing is recommended for the use of unit in full operating temperature range and service life.
CEN/TS 45545-2 mounting notes
Two Viper units can be mounted together and as a single interior non-listed group in the sense of CEN/TS 45545-2 definitions. For multiple units the spacing requirements for interior non-listed groups must be met.
16
6641-2252
Page 17
Getting Started
This product runs Westermo Operating System (WeOS) which provides several management tools that can be used for configuration of the unit.
• IPConfig tool
This is a custom Westermo tool used for discovery of attached Westermo units.
Note! Version of IP Config tool must be 10.4.0 or higher.
• Web
Configuration of the unit using the web browser.
• CLI Configuration of the unit via the Command Line Interface.
If the computer is located in the same subnet as the switch you can easily use a web browser to configure the unit. Within the web you can configure most of the available functions.
For advanced network settings and more diagnostic information, please use the CLI. Detailed documentation is available in the chapter The Command Line Management Tool in the WeOS management guide.
Factory default IP address: 192.168.2.200 Netmask: 255.255.255.0 Gateway: Disabled
Note! If you are not sure about the subnet – consult your network administrator.
Configuration
Configure the unit via web browser
The unit can easily be configured via a web browser. Open the link http://192.168.2.200 in your web browser, and you will be prompted with a Login screen, where the default settings for Username and Password are:
Username: admin Password: westermo
Once you have logged in, you can use the extensive integrated help function describing all configuration options. Two common task when configuring a new switch is to assign appropriate IP settings, and to change the password of the admin account. The password can be up to 64 characters long, and should consist of printable ASCII characters (ASCII 33-126); 'Space' is not a valid password character.
6641-2252
17
Page 18
Referring documents
Type Description Document number
Management Guide Westermo OS management guide
6101-3201
Factory reset
It is possible to set the unit to factory default settings by using two standard Ethernet M12 cables.
1. Power off the switch and disconnect all Ethernet cables.
2. Connect one Ethernet cable between Ethernet ports X1 and X6, and the other between Ethernet ports X2 and X5. The ports need to be connected directly by an Ethernet cable, i.e., not via a hub or switch. Use a straight cable – not a cross-over cable – when connecting the ports.
3. Power on the unit.
4. Wait for the unit to start up. Control that the ON LED is flashing red. The ON LED flashing indicates that the unit is now ready to be reset to factory default.
You now have the choice to go ahead with the factory reset, or to skip factory reset and boot as normal.
• Go ahead with factory reset:
Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cables. The ON LED will stop flashing. This initiates the factory reset process*, the unit will restart with factory default settings. When the switch has booted up, the ON LED will show a green light, and is now ready to use.
• Skip the factory reset:
To skip the factory reset process, just wait for approximately 30 seconds (after the ON LED starts flashing RED) without unplugging the Ethernet cables. The switch will conduct a normal boot with the existing settings.
* Note Do not power off the unit while the factory reset process is in progress.
18
6641-2252
Page 19
Dimensions
3,5
±0,5
81,8 ±1,5
100
±1
23
±1
6,7
±1
164
±1
142
±1
11
±1
M5
177
±1,5
22 ±1
56 ±0,5
6,5
-0 0,5
(4x)
0
1
35
75
110
111
16
0 1,5
24 23,3
48
48,8
72
73,5
99,3
±1,5
110,7
±1,5
Material / Remark
Designation / Dimension
Description
Quantity
Pos No
1:1
Scale
Status
Designer
Drawing No.
PaPu
Sheet
1(1)
Denomination
Viper-12-P8-series
Approved
Date
130225
Description
Designer
Rev
Date
Approved
ToDu
PaPu
01
Created
130225
ToDu
Measurements are stated in millimeters.
6641-2252
19
Page 20
Westermo • SE-640 40 Stora Sundby, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
Sales Units
Westermo Data Communications
E-mail: info@westermo.com
www.westermo.com
China sales.cn@westermo.com www.cn.westermo.com
France infos@westermo.fr www.westermo.fr
Germany info@westermo.de www.westermo.de
For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code
REV. D 6641-2252 2015-06 Westermo Teleindustri AB, Sweden – A Beijer Electronics Group Company
North America
info@westermo.us www.westermo.us
Singapore sales@westermo.com.sg www.westermo.com
Sweden
info.sverige@westermo.se www.westermo.se
United Kingdom sales@westermo.co.uk www.westermo.co.uk
Other Offices
Loading...