Type tests and environmental conditions
Phenomena Test Description Test levels
ESD EN 61000-4-2 Enclosure contact ± 6 kV (crit A)
Enclosure air ± 8 kV (crit A)
RF field AM modulated IEC 61000-4-3 Enclosure 20 V/m 80% AM (1 kHz),
80 – 2500 MHz (crit A)
Fast transient EN 61000-4-4 Ethernet ports ± 2 kV (crit A)
Power port ± 2 kV (crit A)
Earth port ± 2 kV (crit A)
Surge EN 61000-4-5 Fault port ± 2 kV line to earth (crit A)
Ethernet ports ± 2 kV line to earth (crit A)
Power port ± 2 kV line to earth, ± 2 kV line to line
(crit A)
RF conducted EN 61000-4-6 Ethernet ports 10 V 80% AM (1 kHz), 0.15 – 80 MHz
(crit A)
Power port 10 V 80% AM (1 kHz), 0.15 – 80 MHz
(crit A)
Power frequency magnetic
field
EN 61000-4-8 Enclosure 1000 A/m 50 Hz
300 A/m 16.7 Hz, 60 Hz, DC (crit A)
Pulse magnetic field EN 61000-4-9 Enclosure 300 A/m (crit A)
Voltage dips and interruption EN 50155 DC power ports 10 ms interruption, 100 ms ±40% voltage
variation
Radiated emission EN 55022 Enclosure Class B
FCC part 15 Class B
Conducted emission EN 55022 DC power port &
Ethernet ports
Class B
FCC part 15 DC power port Class B
Dielectric strength EN 50155 Ethernet ports to other
isolated ports
707 VDC 1 min
Power & Fault port to
other isolated ports
2121 VDC 1 min
Temperature Operating –40 to +70ºC
Storage & Transport –40 to +70ºC
Humidity Operating 5 to 95% relative humidity
Storage & Transport 5 to 95% relative humidity
Altitude Operating 2000 m / 70 kPa
Reliability prediction (MTBF) MIL-HDBK- 217F Operating Ground Benign:
103 years @ 20ºC
100 years @ 40ºC
90 years @ 60ºC
Ground Mobile:
5.92 years @ 20ºC
5.91 years @ 40ºC
5.88 years @ 60ºC
Service life Operating 10 year
Vibration, random simulated
long life
IEC 60068-2-64,
Cat. 1 class B
(EN 61373)
Not Operating
Vertical: 7.9 m/s
2
Transverse: 7.9 m/s
2
Longitudinal: 7.9 m/s
2
3 x 5 h
Vibration, random functional IEC 60068-2-64,
Cat. 1 class B
(EN 61373)
Operating
Vertical: 1.0 m/s
2
Transverse: 1.0 m/s
2
Longitudinal: 1.0 m/s
2
3 x 10 min