Westermo Viper-012 User Manual

User Guide
6641-2242
Viper-12
SERIES
X1
X2
1
V
SR
X3
2
V
SR
DC
X4
ON
RSTP FRNT
DC
Westermo Teleindustri AB
©
X9
X5
X10
X6
1
X1
X7
X1
USB
X12
X2
X3
CON
X4
X9
X5
X10
X6
1
X1
X7
X12
12-port Ethernet M12 switch / GigE
www.westermo.com
Software tools
Related software tools are available in the folder software tools under technical support on the Westermo website.
License Information
This device contains public available software which is under the GPL license. For more information see legal.pdf included with all firmware releases. This product includes software developed by the OpenSSL Project for use in the
OpenSSL Toolkit. http://www.openssl.org
Legal information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
http://www.westermo.com
2
6641-2242
Safety
!
!
Before installation:
Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from all power supply. Ensure compliance to national installation regulations. This unit relies on convection heating. Make sure that it is installed so that the ambient temperature is within the specified temperature range, e.g. by avoiding obstruction of the airflow around the unit. Also check chapter CEN/TS 45545-2 mounting notes.
Before mounting, using or removing this unit:
Prevent access to hazardous voltage by disconnecting the unit from all power supply.
WARNING
Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.
Before powering-up, a protective earthing conductor must be connected to the protective earthing terminal and have a cross-sectional area of at least 1.5 mm². Note that this unit can be connected to two different power sources.
When this unit is operated at an ambient temperature above +60°C (+140°F), the External Surface of Equipment may exceed Touch Temperature Limit according to EN/IEC/UL 60950-1. To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
6641-2242
3
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfill the warranty obligations:
Do not attempt to dissassemble the unit. There are not any user serviceable
parts inside.
Do not drop, knock or shake the unit. Rough handling above the specification
may cause damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the
unit.
Do not expose the unit to any kind of liquid (water, beverages, paint etc),
unless all connectors are connected or fitted with protective caps (delivered with the unit), tightened to the specified torque. Connected cables must have the appropriate ingress protection code.
Do not use or store the unit in dusty or dirty areas, unless all connectors and
the ventilation membrane are sufficiently protected.
Do not cover or bring mechanical force to the ventilation membrane on the
back of the unit.
If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
4
6641-2242
Agency approvals and standards compliance
Type Approval / Compliance
EMC EN 61000-6-1, Immunity residential environments
EN 61000-6-2, Immunity industrialokokvironments
EN 61000-6-3, Emission residential environments
EN 61000-6-4, Emission industrial environments
EN 50121-3-2, Railway applications – Rolling stock – apparatus
EN 50121-4/IEC 62236-4, Railway signaling and telecommunications apparatus
FCC Part 15 Class B
Safety EN 60950-1, IT equipment
Environmental EN 61373
FCC Part 15.105 Notice:
Railway applications – Rolling stock equipment. Shock and vibration tests
IEEE 1478 Environmental conditions for transit rail car electronic equipment
EN 50124-1 Railway applications – Insulation coordination
EN 50155 Railway applications – Electronic equipment used on rolling stock
IEC 60068-2-27, (shock 100g, 6 ms, halfsine)
CEN/TS 45545-2 Fire safety standard
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful inter­ference to radio communications. However, there is no guarantee that interference will not occur in a partic ular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
… Reorient or relocate the receiving antenna … Increase the separation between the equipment and receiver … Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected
… Consult the dealer or an experienced radio/TV technician for help.
6641-2242
5
th
Declaration of Conformity
Westermo Teleindustri AB
Declaration of conformity
The manufacturer Westermo Teleindustri AB
Herewith declares that the product(s)
Type of product Model Art no 12-port unmanaged Ethernet M12 Switch Viper-012 3641-0540 12-port managed Ethernet M12 Switch Viper-112, -212 3641-0555, -0560
is in conformity with the following EC directive(s).
No Short name
2004/108/EC Electromagnetic Compatibility (EMC) 2006/95/EC Low Voltage (LVD) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic
References of standards applied for this EC declaration of conformity. No Title Issue
EN 50121-3-2 Railway applications – Electromagnetic compatibility – Rolling stock -
EN 50121-4 Railway applications – Electromagnetic compatibility – Emission and immunity
EN 61000-6-1 Electromagnetic compatibility - Generic standards - Immunity for residential,
EN 61000-6-2 Electromagnetic compatibility - Generic standards - Immunity for industrial
EN 61000-6-3 Electromagnetic compatibility – Emission for residential environments 2007
EN 61000-6-4 Electromagnetic compatibility - Generic standards - Emission standard for
EN 60950-1 Information technology equipment – Safety – General require ments 2006
EN 50581 Technical documentation for the assessment of electrical and electronic products
The last two digits of the year in which the CE marking was affixed: 15
SE-640 40 Stora Sundby, Sweden
equipment (RoHS)
Apparatus
of the signaling and telecommunications apparatus
commercial and light-industrial environments
environments
industrial environments
with respect to the restriction of hazardous substances
2015
2015
2007
2005
+ A1:2011 2007 +A1:2011
+A11:2009 +A1:2010 +A12:2011 2012
Pierre Öberg Technical Manager 20
September 2015
Org.nr/ Postadress/Postal address
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
Tel.
Telefax
Postgiro
Bankgiro Corp. identity number Registered office
6
6641-2242
th
Declaration of Conformity
Westermo Teleindustri AB
Declaration of conformity
The manufacturer Westermo Teleindustri AB
Herewith declares that the product(s)
Type of product Model Art no 12-port managed Gig Ethernet M12 Switch Viper-112-T3G, -212-T3G 3641-0530, -0550
is in conformity with the following EC directive(s).
No Short name
2004/108/EC Electromagnetic Compatibility (EMC) 2006/95/EC Low Voltage (LVD) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic
References of standards applied for this EC declaration of conformity. No Title Issue
EN 50121-3-2 Railway applications – Electromagnetic compatibility – Rolling stock -
EN 50121-4 Railway applications – Electromagnetic compatibility – Emission and immunity
EN 61000-6-1 Electromagnetic compatibility - Generic standards - Immunity for residential,
EN 61000-6-2 Electromagnetic compatibility - Generic standards - Immunity for industrial
EN 61000-6-3 Electromagnetic compatibility – Emission for residential environments 2007
EN 61000-6-4 Electromagnetic compatibility - Generic standards - Emission standard for
EN 60950-1 Information technology equipment – Safety – General require ments 2006
EN 50581 Technical documentation for the assessment of electrical and electronic products
The last two digits of the year in which the CE marking was affixed: 15
SE-640 40 Stora Sundby, Sweden
equipment (RoHS)
Apparatus
of the signaling and telecommunications apparatus
commercial and light-industrial environments
environments
industrial environments
with respect to the restriction of hazardous substances
2006
2006
2007
2005
+ A1:2011 2007 +A1:2011
+A11:2009 +A1:2010 +A12:2011 2012
Pierre Öberg Technical Manager 20
September 2015
Org.nr/ Postadress/Postal address
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
Tel.
Telefax
Postgiro
Bankgiro Corp. identity number Registered office
6641-2242
7
Loading...