Safety
Before installation:
!
Read this manual completely and gather all information on the unit. Make sure
that you understand it fully. Check that your application does not exceed the safe
operating specifications for this unit.
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is
restricted to service personnel only.
The power supply wiring must be sufficiently fused, and if necessary it must be
possible to disconnect manually from the power supply. Ensure compliance to
national installation regulations.
Branch circuit protection (fuse) is required for this unit with rating not
exceeding 20 A.
Product should be connected to UL Listed power supplies rated 12 – 48 VDC,
min 500 mA or 24 VAC, min 500 mA or reliably grounded DC SELV source*.
This unit uses convection cooling. To avoid obstructing the airflow around the
unit, follow the spacing recommendations (see Cooling section).
!
Before mounting, using or removing this unit:
Prevent access to hazardous voltages by disconnecting the unit from the power
supply.
Warning! Do not open a connected unit. Hazardous voltages may occur within
!
this unit when connected to a power supply.
Class 1 Laser Product
This unit is designed to meet the Class 1 Laser regulations. However, the user is warned
not to look directly into fibre optical fibre port or any connected fibre.
Care recommendations
Follow the care recommendations below to maintain full operation of the unit and to
fulfil the warranty obligations.
This unit must not be operated with covers or lids removed.
Do not attempt to disassemble the unit. There are no user serviceable parts inside.
Do not drop, knock or shake the unit. Rough handling beyond the specification may
cause damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
Do not paint the unit. Paint can clog the unit and prevent proper operation.
Do not expose the unit to any kind of liquids (rain, beverages, etc).
The unit is not waterproof. Keep the unit within the specified humidity levels.
Do not use or store the unit in dusty, dirty areas. Connectors as well as other
mechanical parts may be damaged.
If the unit is not working properly, contact the place of purchase, nearest Westermo
distributor office, or Westermo Tech support.
Fibre connectors are supplied with plugs to avoid contamination inside the optical port.
The plug should be fitted when no optical fibre is inserted in the connector, e.g. during
storage, service or transportation.
* Applicable for ODW-710-F1 only
6651-2201
3
Page 4
Note. Fibre Optic Handling
Fibre optic equipment requires careful handling as the fibre components are very
sensitive to dust and dirt. If the fibre is disconnected from the modem, the protective
plug on the transmitter/receiver must be replaced. The protective plug must be kept on
during transportation. The fibre optic cable must also be protected in the same way.
If this recommendation is not followed, it can jeopardise the warranty.
Cleaning of the optical connectors
In the event of contamination, the optical connectors should be cleaned by using forced
nitrogen and some kind of cleaning stick.
Recommended cleaning fluids:
• Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
• Hexane
• Naphtha
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified
conditions.
EN 50121-4, Railway signalling and telecommunications apparatus
IEC 62236-4, Railway signalling and telecommunications apparatus
DNV Standard for Certification no. 2.4***
SafetyUL/CSA/IEC/EN 60950-1, IT equipment*
EN 60950-1, IT equipment**
ATEX**EN 60079-0 and EN 60079-15
* Applicable for ODW-710-F1 only
** Applicable for ODW-710-F1 Ex only
*** Applicable only for article number 3651-0711
FCC Part 15.105
Notice:
EN 55022 Notice:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
4
6651-2201
Page 5
ATEX Information (Applicable for ODW-710-F1 EX only)
General
This unit is intended for use in Zone 2 hazardous location only.
Marking
II 3 G
Ex nA IIC T4 Gc
SPECIAL CONDITION
WARNING – DO NOT SEPARATE WHEN ENERGIZED
Indicate that this unit complies with relevant European standards that are
harmonised with the 94/9/EC Directive (ATEX).
II
3
G
ExIndicates that this unit is in conformity with relevant European Ex standard(s).
nA
IICGas group, a typical gas i hydrogen.
T4
Gc
SPECIAL
CONDITION
Equipment group II.
This unit can be installed in all places with an explosive gas atmosphere other
than mines susceptible to firedamp
Equipment category 3.
A category is the classification according to the required level of protection.
This unit ensures the requisite level of protection during normal operation and
is intended for use in areas in which explosive atmosphere caused by gases,
vapours, mists, or dust mixtures are unlikely to occure or, if they do occure, are
likely to do so only infrequently and for a short periode only.
Indicates protection concerning explosive atmospheres caused by gases,
vapours or mists (G).
Type of protection used.
This unit is a non-sparking device "nA" which is constructed to minimize the
risk of occurence of arcs or sparks capable of creating an ignition hazard during
conditions of normal operation.
Temperature class T4 (T4 = 135°C).
This unit is classified in accordance with its maximum surface temperature
(external and internal).
Equipment protection level Gc (EPL Gc).
Equipment for explosive gas atmospheres, having a "enhanced" level of protection, which is not a source of ignition in normal operation and which may have
some additional protection to ensure that it remains inactive as an ignition
source in the case of regular expected occurences. EPL Gc are analogous to the
ATEX Categories (Category 3 G = EPL Gc).
This unit has a special condition of use.
The special condition for safe use contains safety related information that is
necesarry for the correct installation and safe use.
6651-2201
5
Page 6
Ratings
Power (12 – 48) VDC; 300 mA
Ambient temperature –40ºC ≤ Ta ≤ +70ºC
Ingress protection (IP)IP21
Maximum surface temperatur 135ºC (temperature class T4)
Safety Control Drawing
Degree of protectionIP 21
Ambient temperature–40°C to +70°C
Installation spacing
Direction relative this unit!
1234
Minimum 25 mm above / below
Minimum 10 mm left / right
Position DescriptonInput / Output values
1In & out / Relay contact (NO)
2In & out / Relay contact (C)
3In & out / Relay contact (NC)
Galvanically isolated via mechanical relay.
See user manual for proven transient protection.
See section Type tests and environmental conditions in this
user manual for proven transient protection.
6
Uin = (10 – 60) VDC
Iin = 400 mA max
PIn = Max 4 W
Max 0 dBm
6651-2201
Page 7
SPECIAL CONDITION FOR SAFE USE
Ambient temperature:
This unit is designed for use in extreme ambient temperature conditions as follows:
–40 ºC ≤ Ta ≤ +70 ºC
Installation in an apparatus cabinet:
This unit requires installation in an Ex certified apparatus cabinet suitable for the area of use and
providing a degree of protection of at least IP54.
Resistance to impact:
This unit requires installation in an apparatus cabinet where adequate resistance to impact is
provided by the apparatus cabinet. See "Installation in an apparatus cabinet" above for requirements
on the external apparatus cabinet.
Resistance to light:
This unit requires installation in an apparatus cabinet where it is protected from light
(for example daylight or light from luminaires).
See "Installation in an apparatus cabinet" above for requirements on the external apparatus cabinet.
Secureness of plugs:
When this unit is installed in an explosive atmospheres, all connectors must be mechanically secured
to prevent loosening.
Conductor temperature:
When this unit is installed in locations with high ambient temperature, special precautions shall be
taken upon the choice of external conductors and the temperature rating of the conductor(s).
Directive 94/9/EC alongside with other directives:
Directive 2004/108/EC (EMC) applies and to assure a safe performance of this unit under the scope
of Directive 94/9/EC, refer to the electromagnetic immunity level specified under "Type tests and
environmental conditions" in this manual.
Standards and date of compliance
EN 60079-0 and EN 60079-15
2010-12-17
6651-2201
7
Page 8
Declaration of Conformity
Org.nr/
Registered office
Westermo Teleindustri AB
Declaration of conformity
The manufacturer Westermo Teleindustri AB
Herewith declares that the product(s)
Type of product Model Art no
Industrial fiberoptic repeaters/media
converters
is in conformity with the following EC directive(s).
RF field AM modulated IEC 61000-4-3Enclosure10 V/m 80% AM (1 kHz), 80 – 800 MHz
RF field 900 MHzENV 50204Enclosure20 V/m pulse modulated 200 Hz, 900 ± 5 MHz
Fast transientEN 61000-4-4Signal ports± 2 kV
SurgeEN 61000-4-5Signal ports unbalanced ± 2 kV line to earth, ± 2 kV line to line
RF conductedEN 61000-4-6Signal ports10 V 80% AM (1 kHz), 0.15 – 80 MHz
Pulse Magnetic fieldEN 61000-4-9Enclosure300 A/m, 6.4 / 16 µs pulse
Voltage dips
and interruption
Mains freq. 50 HzEN 61000-4-16 Signal ports100 V 50 Hz line to earth
Mains freq. 50 HzSS 436 15 03Signal ports250 V 50 Hz line to line
Radiated emission EN 55022EnclosureClass B
Conducted emissionEN 55022AC power portsClass B
Dielectric strengthEN 60950Signal port to all other
Environmental
TemperatureOperating–40 to +70°C
HumidityOperating5 to 95% relative humidity
AltitudeOperating2 000 m / 70 kPa
Service lifeOperating10 year
VibrationIEC 60068-2-6Operating7.5 mm, 5 – 8 Hz
ShockIEC 60068-2-27 Operating15 g, 11 ms
Packaging
Enclosure, ODW-710-F1 UL 94PC / ABSFlammability class V-1
Enclosure,
ODW-710-F1 EX
Dimension W x H x D35 x 121 x 119 mm
Weight0.26 kg
Degree of protectionIP 21
CoolingIEC 529EnclosureConvection
MountingHorizontal on 35 mm DIN-rail
EN 61000-4-11 AC power ports10 & 5 000 ms, interruption
FCC part 15Class A
FCC part 15AC power portsClass B
EN 55022DC power portsClass A
Enclosure air± 8 kV
20 V/m 80% AM (1 kHz), 800 – 1000 MHz
20 V/m 80% AM (1 kHz), 1400 – 2700 MHz
Power ports± 2 kV
Signal ports balanced± 2 kV line to earth, ± 1 kV line to line
Power ports± 2 kV line to earth, ± 2 kV line to line
Power ports10 V 80% AM (1 kHz), 0.15 – 80 MHz
200 ms, 40% residual voltage
500 ms, 70% residual voltage
OVP Over Voltage Protection
OCP Over Current Protection
Converter PROFIBUS DP – optical fibre
ODW-710-F1 is a fibre optic modem that converts between electrical PROFIBUS DP and
a fibre optical link.
Data rate up to 12 Mbit/s
ODW-710-F1 converts PROFIBUS DP data using data rates from 9 600 bit/s up to
12 Mbit/s. Retiming of the PROFIBUS DP data ensures that the correct signal form is
transmitted from the ODW-710-F1 converter.
Automatic data rate detection
The PROFIBUS data rate is set automatically as soon as the ODW-710-F1 receives a
correct data frame, whether data is received from PROFIBUS DP or the fibre optic link.
The detected data rate remains until a number of consecutive faulty received frames have
been detected or no further frames are detected within the timeout period. The timeout
period is set by switches, with the default setting of 31 faulty frames or 5 seconds without any received frames.
10
6651-2201
Page 11
Interface specifications
Power
Rated voltageODW-710-F1: 12 to 48 VDC and 24 VAC
Operating voltageODW-710-F1: 10 to 60 VDC and 20 to 30 VAC
Rated current300 mA @ 12 VDC
Rated frequencyODW-710-F1: DC and 48 to 62 Hz
Inrush current I2t0.2 A2s
Startup current*1.0 Apeak
PolarityReverse polarity protected
Redundant power inputYe s
Isolation toPROFIBUS DP and Status port
ConnectionDetachable screw terminal
Connector size0.75 – 2.5 mm2 (AWG 18 – 13)
Shielded cableNot required
* External supply current capability for proper startup
Status
Port typeSignal relay, changeover contacts
Rated voltageUp to 48 VDC
Operating voltageUp to 60 VDC
Contact rating500 mA @ 48 VDC
Contact resistance< 50 mW
Isolation toPROFIBUS DP and Power port
ConnectionDetachable screw terminal
Connector size0.2 – 2.5 mm2 (AWG 24 – 13)
Shielded cableNot required
ODW-710-F1 Ex: 12 to 48 VDC
ODW-710-F1 Ex: 10 to 60 VDC
150 mA @ 24 VDC
75 mA @ 48 VDC
ODW-710-F1 Ex: DC
Connect the unit using at least 18 AWG (0.75 mm2) wiring
6651-2201
11
Page 12
PROFIBUS DP (RS-485)
Electrical specificationEIA RS-485 / EN 50 170
Data rate9 600 bit/s, 19.2, 93.75, 187.5, 500 kbit/s, 1.5, 3, 6 and 12 Mbit/s
Data format8 data bits, even parity, 1 stop bit, 11 bits total
ProtocolPROFIBUS DP / EN 50170
Data Rate detectionYes, compliant with EN 50 170
RetimingYe s
Turn around timeIn accordance with EN 50 170
Transmission range≤ 1200 m, depending on data rate and cable type (EIA RS-485)
SettingsNone, external termination and failsafe biasing
ProtectionInstallation Fault Tolerant (up to ±60 V)
Isolation toPower and Status port
Connection9-pin D-sub female
Shielded cableNot required
Conductive housingIsolated to all other circuits and housings
12
6651-2201
Page 13
Location of Interface ports, LED’s and DIP-switches
ODW-710-F1
LED Indicators(for details see page 15)
FX(Fibre)
(for details
see page 12–13)
DIP-switches accessible under lid
(for details see page 16–17)
* Only valid if used togheter with ODW-710-F2 units in a multidrop network.
Note: During power up, all LED’s will turn on for about 1 second.
ONPower is on.
OFFPower is off.
ONData rate has been identified and
data frames are being received on
the electrical or optical interface.
OFFData rate has not been identified.
ONFibre link to other unit has been
established at CH 1.
Flashing Optical power detected but link to
other unit has not been established
at CH 1.
OFFNo optical power detected and
no link to other unit has been
established at CH 1.
FlashData received on the electrical
interface and transmitted out on
the optical interface.
OFFNo data received on the electrical
interface.
FlashData received on the optical interface
and transmitted out on the electrical
interface.
OFFNo data received on the optical
interface.
ONRemote fibre link failure. A fibre link
is out of operation at any other unit
than this one.*
Flashing Hardware error or invalid configura-
tion.
ONLocal fibre link failure. A fibre link is
out of operation.
Flashing Hardware error or invalid configura-
tion.
14
6651-2201
Page 15
DIP-switch settings
Before setting DIP-switches:
!
Prevent damage to internal electronics from electrostatic discharges (ESD)
by discharging your body to a grounding point (e.g. use of wrist strap).
S2S1
S2 DIP-switch
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Multidrop mid unit or
redundant ring member.
N/A for ODW-710-F1
Multidrop end unit. E.g. the first or
last unit in a multidrop network.
Always "ON" for ODW-710-F1
Redundant ring focal point
Only one focal point allowed
in a ring. N/A for ODW-710-F1
65535 t
interruption in receiving
bit
frames, until inactive BA.
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
* See section “About the automatic data rate detection”
on page 23 for a more detailed description.
5 seconds interruption in receiving
frames, until inactive BA
10 seconds interruption in receiving
frames, until inactive BA
20 seconds interruption in receiving
frames, until inactive BA
*
.
*
.
*
.
6651-2201
15
Page 16
S1
DIP-switch
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
S2
DIP-switch
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Description
1 faulty frame before data rate seen as unidentified*.
S1: No extended retry limit.
2 faulty frames before data rate seen as unidentified*.
S1: No extended retry limit.
3 faulty frames before data rate seen as unidentified*.
S1: No extended retry limit.
4 faulty frames before data rate seen as unidentified*.
S1: No extended retry limit.
5 faulty frames before data rate seen as unidentified*.
S1: No extended retry limit.
6 faulty frames before data rate seen as unidentified*.
S1: No extended retry limit.
7 faulty frames before data rate seen as unidentified*.
S1: No extended retry limit.
8 faulty frames before data rate seen as unidentified*.
S1: No extended retry limit.
31 faulty frames before data rate seen as unidentified*.
S1: Extended retry limit.
63 faulty frames before data rate seen as unidentified*.
S1: Extended retry limit.
127 faulty frames before data rate seen as unidentified*.
S1: Extended retry limit.
255 faulty frames before data rate seen as unidentified*.
S1: Extended retry limit.
Set status port at local fibre link (FL L) error only.
Only applicable if used togheter with ODW-710-F2 units in a multidrop
network.
Factory default
* See section “About the automatic data rate detection” on page 22 for a more detailed description.
16
6651-2201
Page 17
Start up guide
Follow the steps below to get the unit up and running in a simple application.
PROFIBUS DPPROFIBUS DP
PROFIBUS DP master
POWERCH 1
COM +VA +VB COM
PROFIBUS DP slave
POWERCH 1
COM +VA +VB COMTX RXTX RX
Fibre Optic
… Use the factory DIP-switch settings.
… Connect The fibre link between the both units.
… Connect the power supply to both units.
The Fibre link should be in operation as indicated by the CH1 LED.
… Connect the PROFIBUS DP connectors between both ODW-710-F1 and PROFIBUS
units configured to be units in the PROFIBUS DP network.
The PROFIBUS DP will be in operation and the data rate will be automatically detected, as indicated by the BA LED.
… The point to point application is up and running.
Note: In an ODW-710-F1 fibre optic link there will be some additional processing
delays that do not exist in an electrical bus. It is possible that the PROFIBUS
application must be adjusted to accommodate for this delay. See page 21
“Calculating system processing delay” for more information on how to
determine the overall system delay time.
6651-2201
17
Page 18
LED indication under normal operation
RX1
TX1
ODW-710
PROFIBUS
Slave
ODW-710
PROFIBUS
Master (PLC)
TX1
RX1
Data from the PROFIBUS master is received at the ODW-710-F1 electrical port (as indicated by the DPR LED), data rate is automatically detected (as indicated by the BA LED),
data bits are retimed according to the determined rate and sent out on the optical fibre
at CH 1.
The ODW-710-F1 slave unit receives data at optical fibre CH 1 (as indicated by the
FR LED), data rate is automatically detected (as indicated by the BA LED) and data is
sent out on the electrical port.
Responses from the PROFIBUS slaves are processed in the same fashion and sent back
to the PROFIBUS master in the opposite direction.
18
6651-2201
Page 19
LED indication during optical link failure
TX1
RX1
ODW-710ODW-710
Master
FL L LED
is on
CH 1 LED
is off
PROFIBUS
Faulty
fibre
RX1
TX1
PROFIBUS
Slave
FL L LED
is on
CH 1 LED
is flashing
If one fiber in the optical fibre pair fails, all cummunication with will be lost and the FL R
LED’s will turn on. The ODW-710-F1 that is still sensing optical power will indicate this
by flashing the CH1 LED.
TX1
RX1
ODW-710ODW-710
CH 1 LED
is off
FL L LED
is on
Faulty
fibres
RX1
TX1
FL L LED
is on
CH 1 LED
is off
PROFIBUS
Master
PROFIBUS
Slave
If both fibers in the optical fibre pair fails, all cummunication with will be lost, the CH1
LED’s will turn off and the FL R LED’s will turn on.
6651-2201
19
Page 20
Calculating system processing delay
Data exchange between a PROFIBUS DP master and slave via ODW-710-F1 fibre optic
link, will be delayed due to the length of the optical fibre and the signal processing within
the ODW-710-F1. The signal processing delay is dependent on the data rate, and the fibre
delay is dependent on the total length of the optical fibre. The additional time resulting
from the optical fibre and ODW-710-F1 is the Overall system delay.
Signal processing, electrical to fibre (max)1 tbit + 1 µs9 tbit + 1 µs
Signal processing, fibre to electrical (max)0.3 µs0.3 µs
Signal processing, fibre to fibre (max)1.3 µs1.3 µs
Note! tbit = 1 / Baud rate (Baud rate in bit/s)
Example
One PROFIBUS DP master and slave using a data rate of 12 Mbit/s. and a total fibre length of 40 km.
A data frame sent from the master to a slave.
1. Fibre: The total optical fibre length delay.
40 x 5 µs = 200 µs
2. Converter electrical to fibre: Signal processing delay
(ODW-710-F1 connected to PROFIBUS DP master).
9 tbit + 1 µs = 9 x 0.083 µs + 1 µs ≈ 1.1 µs
3. Converter fibre to electrical: Signal processing delay
(ODW-710-F1 connected to addressed slave).
0.3 µs
4. The system delay is calculated by summing the delays in item 1 to 3 above:
200 µs + 1.1 µs + 0.3 µs = 201.4 µs
20
6651-2201
Page 21
About the interfaces
Power
The power terminal has two independent inputs, +VA and +VB, allowing redundant
power input. The ODW-710-F1 power supply is galvanically isolated from all other interfaces.
Optical fibre interfaces
ODW-710-F1 uses Small Form Factor Pluggable (SFP) transceivers. This means that a
wide range of different fibre transceivers and connectors can be used (see page 12).
PROFIBUS DP interface
The PROFIBUS DP interface is a female 9-position D-sub. Pin assignments are compliance with the PROFIBUS standard EN 50 170.
Status port
The status port connects to an internal relay witch may be used to trigger an external
alarm if a fault condition occurs. During normal operation pins 1 and 2 are in contact
with each other, and pins 2 and 3 are isolated. During an optical link failure, or power
failure, pins 1 and 2 are isolated, and pins 2 and 3 are in contact with each other.
Optical link failures can be classified in to two categories, local or remote, as indicated by
the FL L and FL R LED’s. A local link failure is when an optical link is down at this particular unit. A remote link failure is when an optical link is down at some other unit.
From the factory, the status port is set to trigger on both types of link failures. However,
by setting DIP-switch S1:1 to the ON position, the status port will only trigger when a
local link failure has occurred.
Note: Setting DIP-switch S1:1 ON is only applicate if using the ODW-710-F1 togheter
with ODW-710-F2 in a multidrop network.
6651-2201
21
Page 22
About the automatic data rate detection
ODW-710-F1 automatically detects the data rate by monitoring incoming PROFIBUS data
frames on both the electrical and optical interfaces. When the data rate has been established the BA LED will go active.
If no data frames are transmitted for a period of time the automatic data rate detection
will restart and the BA LED will go inactive.
The idle time before the automatic data rate detection re-starts is set using DIP-switches
S2:4 and S2:5. The factory default setting is 5 seconds.
The automatic data rate detection determines the actual data rate by listening for
PROFIBUS Start Delimiters (SD1 – SD4) at the beginning of each data frame. If one or
more Start Delimiters are lost the automatic data rate detection will re-start.
The number of lost Start Delimiters before the automatic data rate detection re-starts
is set using DIP-switches S1:2 and S2:6 – S2: 8. The factory default setting is 31 faulty
frames (31 lost Start Delimiters).
Note: Start Delimiters can be lost during an electrical or optical disturbance.
For example a PROFIBUS slave unit is connected/disconnected or an optical fibre is
disconnected. It is advisable to start of by using the factory default settings and only
manipulate them if a problem exists.
22
6651-2201
Page 23
Mounting
CLICK!
This unit should be mounted on 35 mm DIN-rail, which is
horizontally mounted inside an apparatus cabinet, or similar.
Snap on mounting, see figure.
Cooling
This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Minimum
spacing 25 mm (1.0 inch) above /below and 10 mm (0.4 inches)
left /right the unit. Spacing is recommended for the use of unit
in full operating temperature range and service life.
10 mm *
(0.4 inches)
25 mm
* Spacing (left/right) recommended for
full operating temperature range
Removal
Press down the black support at the top of the unit. See figure.
6651-2201
25 mm
23
Page 24
Westermo • SE-640 40 Stora Sundby, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
Sales Units
Westermo Data Communications
E-mail: info@westermo.com
www.westermo.com
China
sales.cn@westermo.com
www.cn.westermo.com
France
infos@westermo.fr
www.westermo.fr
Germany
info@westermo.de
www.westermo.de
For complete contact information, please visit our website at www.westermo.com/contact
REV.G 6651-2201 2014-10 Westermo Teleindustri AB, Sweden – A Beijer Electronics Group Company
North America
info@westermo.com
www.westermo.com
Singapore
sales@westermo.com.sg
www.westermo.com
Sweden
info.sverige@westermo.se
www.westermo.se
or scan the QR code with your mobile phone.
United Kingdom
sales@westermo.co.uk
www.westermo.co.uk
Other Offices
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.