Westermo L205-S1, Lynx DSS L208-F2G-S2, L105-S1, Lynx DSS L108, Lynx DSS L108-F2G-S2 User Manual

...
Page 1
©
Westermo Teleindustri AB
www.westermo.com
User Guide
6643-2230
Industrial Ethernet
5-port Device Server Switch
L105-S1/L205-S1
WeOS
Page 2
2
6643-2230
Legal information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
http://www.westermo.com
Software tools
Related software tools are available in the folder software tools under technical support on the Westermo website.
Page 3
3
6643-2230
Safety
Before installation:
Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from all power supply. Ensure compliance to national installation regulations. This unit uses convection cooling. Make sure that the unit is installed such as its ambient temperature is within its specified maximum/minimum temperature.
Before mounting, using or removing this unit:
Prevent access to hazardous voltage by disconnecting the unit from all power supply.
WARNING
Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply. Before powering-up, a protective earthing conductor must be connected to the protective earthing terminal and have a cross-sectional area of at least 1.5 mm². Note that this unit can be connected to two different power sources. When this unit is operated at an ambient temperature above +55°C (+131°F), the External Surface of Equipment may exceed Touch Temperature Limit according to EN/IEC/UL 60950-1. To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfill the warranty obligations. This unit must not be operating with removed covers or lids. Do not attempt to disassemble the unit. There are not any user serviceable parts inside. Do not drop, knock or shake the unit. Rough handling above the specification may cause damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not expose the unit to any kind of liquids (rain, beverages, paint etc), unless all connectors and the ventilation membrane are sufficiently protected. Do not use or store the unit in dusty or dirty areas, unless all connectors and the ventilation membrane are sufficiently protected. Do not cover or bring mechanical force to the ventilation membrane on the back of the unit. If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
! !
Page 4
4
6643-2230
Agency approvals and standards compliance
Type Approval / Compliance
EMC EN 61000-6-1, Immunity residential environments
EN 61000-6-2, Immunity industrial environments
EN 61000-6-3, Emission residential environments
EN 61000-6-4, Emission industrial environments
EN 50121-4, Railway signalling and telecommunications apparatus
IEC 62236-4, Railway signalling and telecommunications apparatus
Safety UL/IEC/EN 60950-1, IT equipment
Marine DNV GL rules for classification – Ships and offshore units .
FCC Part 15.105 Notice:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
… Reorient or relocate the receiving antenna … Increase the separation between the equipment and receiver … Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
… Consult the dealer or an experienced radio/TV technician for help.
Corrosive environment
Notice:
This product has been successfully tested in a corrosion test according to IEC 60068-2-60, method 3. This means that the product meets the requirements to be placed in an environment classified as ISA-S71.04 class G3.
Note! If the product is placed in a corrosive environment, it is important that all un-used connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated pins in connectors.
Page 5
5
6643-2230
Declaration of Conformity
Westermo Teleindustri AB
Declaration of Conformity
Org.nr/
Postadress/Postal address
Tel.
Telefax
Postgiro
Bankgiro
Corp. identity number Registered office
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
The manufacturer
Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden
Herewith declares that the product(s)
Type of product Model 1 Industrial Ethernet 5-port Device Server Switch Lynx DSS Lx05-S1y
is in conformity with the following EU directive(s).
No Short name 2014/30/EU Electromagnetic Compatibility (EMC)
2014/35/EU Low Voltage Directive (LVD) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic
equipment (RoHS)
References of standards applied for this EU declaration of conformity.
No Title Issue EN 61000-6-1 Electromagnetic compatibility – Immunity for residential
environments
2007
EN 61000-6-2 Electromagnetic compatibility – Immunity for industrial
environments
2005
EN 61000-6-3 Electromagnetic compatibility – Emission for residential
environments
2007 +A1:2011
EN 61000-6-4 Electromagnetic compatibility – Emission for industrial
environments
2007 +A1:2011
EN 50121-4 Railway applications - Electromagnetic compatibility
Emission and immunity of the signalling and telecommunications apparatus
2006
EN 60950-1 Information technology equipment - Safety - Part 1: General
requirements
2006 +A11: 2009 +A1: 2010 +A12: 2011
EN 50581 Technical documentation for the assessment of electrical and
electronic products with respect to the restriction of hazardous substances
2012
The last two digits of the year in which the CE marking was affixed: 16
Pierre Öberg Technical Manager 21
st
March 2016
1
Model Differences: x = 1 or 2 and indicates Software Class, y = optional and may indicate customer specific models.
Page 6
6
6643-2230
Type tests and environmental conditions
Environmental phenomena Basic standard Description Test levels
Electrostatic discharge EN 61000-4-2 Enclosure Contact: ±6 kV
Air: ±8 kV
Fast transients EN 61000-4-4 Power port ±2 kV
Ethernet Status out/Digital in Serial ports Enclosure
Surge EN 61000-4-5 Power port L-L: ±0.5 kV, 2 Ω, 18 μF
L-E: ±2 kV, 42 Ω, 0.5 μF L-L: ±1 kV, 42 Ω, 0.5 μF L-E: ±2 kV, 12 Ω, 9 μF
L-L: ±1 kV, 12 Ω, 9 μF Ethernet L-E: ±2 kV, 2Ω, 0.5 μF Status out/Digital in L-E: ±2 kV, 42 Ω, 0.5 μF
L-L: ±1 kV, 42 Ω, 0.5 μF RS-232 L-E: ±2 kV, 2 Ω, 0.5 μF
Power frequency magnetic field EN 61000-4-8 Enclosure 300 A/m; 0, 16.7, 60 Hz
1000 A/m; 50 Hz
Pulsed magnetic field EN 61000-4-9 Enclosure 300 A/m Radiated RF immunity EN 61000-4-3 Enclosure 20 V/m @ (80 – 2700) MHz
1 kHz sine, 80% AM
Conducted RF immunity EN 61000-4-6 Power port 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Ethernet Status out/Digital in Serial ports Earth port
Radiated RF emission CISPR 16-2-3
ANSI C63.4 (FCC part 15)
Enclosure Class B / DNV bridge
Conducted RF emission CISPR 16-2-1
ANSI C63.4 (FCC part 15)
Power port Class B / DNV bridge Ethernet Class B
Dielectric strength EN 60950-1 Power port to all
other ports
1.5 kVrms, 50 Hz, 1 min
Ethernet ports to all other ports
RS-232 port to all other ports
Page 7
7
6643-2230
Environmental
Temperatures EN 60068-2-1
EN 60068-2-2
Operating –40 to +70°C (–40 to +158°F)* Storage and transport –50 to +85°C (–58 to +185°F)
Humidity EN 60068-2-30 Operating 5 to 95 % relative humidity
Storage and transport 5 to 95 % relative humidity Altitude Operating 2 000 m / 70 kPa MTBF MIL-C217F2,
Parts count
Ground Benign, 25°C
(77°F)
677 000 hours
Service life Operating 10 year Vibration IEC 60068-2-6
(sine)
Operating 3 – 13.2 Hz: 1mm
13.2 – 100 Hz: 0.7 g
5.5 – 30 Hz: 1.5 g 30 – 50 Hz: 0.42 mm 50 – 500 Hz: 4.2 g**
IEC 60068-2-64 (random)
5 – 20 Hz: 2 m²/s³, 20 – 2000 Hz: – 3 dB/oct
Shock IEC 60068-2-27 Operating 30 g, 11 ms
100 g, 6 ms**
Bump IEC 60068-2-27 Operating 10 g, 11 ms
Packaging
Enclosure EN 60950-1 Zinc Fire enclosure Dimension W x H x D
With connectors
52.5 x 100 x 101 mm
52.5 x 119 x 101 mm Weight 0.7 kg Degree of protection EN 60529 Enclosure IP 40 Cooling Convection
* Refer to “Safety” section in User Guide. ** Might require Ethernet cables to be fastened close to the unit.
Page 8
8
6643-2230
Description
L105-S1/L205-S1 is an Industrial switch and device server made for harsh environments. WeOS is the operating system of L105-S1/L205-S1 enabling the unit to operate in two functional levels. The switch can be used in either 10 or 100 Mbit networks. Lynx DSS L105-S1/L205-S1 has one serial port that supports RS-232.
Our unique FRNT (Fast Recovery of Network Topology) technology is the fastest protocol on the market to re-configure a network in the event of any link or hardware failure. That is why our products are used in safety critical applications such as tunnels, traffic signal control and railway systems.
Page 9
9
6643-2230
Interface specifications
Power
Operating voltage Rated: 24 to 48 VDC
Operating: 19 to 60 VDC
Rated current 140 mA (290 mA) @ 24 VDC (with 500 mA USB load)
70 mA (140 mA) @ 48 VDC (with 500 mA USB load) Rated frequency DC Inrush current, I2t 22.7·10-3 A2s @ 48 VDC Startup current* 2 x Rated current Polarity Reverse polarity protected Redundant power input Ye s Isolation to All other Connection Detachable screw terminal Connector size 0.2 – 2.5 mm2 (AWG 24 – 12) Shielded cable Not required
* External supply current capability for proper start-up
Ethernet TX
Electrical specification IEEE std 802.3. 2005 Edition Data rate 10 Mbit/s, 100 Mbit/s, manual or auto Duplex Full or half, manual or auto Circuit type TNV-1 Transmission range Up to 150 m with CAT5e cable or better* Isolation to All other Connection RJ-45, auto MDI/MDI-X Cabling Shielded CAT5e or better is recommended Conductive housing Ye s Number of ports 4
* Refer to Safety section.
RS-232
Electrical specification EIA RS-232 Data rate 50 bit/s – 115.2 kbit/s Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits Protocol Transparent, optimised by packing algorithm Circuit type SELV Transmission range 15 m / 49 ft Isolation to All other Connection RJ-45 according to EIA-561 Shielded cable Recommended Conductive housing Ye s Number of ports 1
Page 10
10
6643-2230
I/O / Relay output
Maximum voltage/current 60 VDC / 80 mA Contact resistance Max 30 Ω Isolation to All other Connection Detachable screw terminal Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
I/O / Digital input Maximum voltage/load current 60 VDC / 2 mA Voltage levels Logic one: >12V
Logic zero: <1V Isolation to All other Connection Detachable screw terminal Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
USB
Electrical specification USB 2.0 host interface Data rate Up to 12 Mbit/s (full-speed mode) Circuit type SELV Maximum supply current 500 mA Connection USB receptacle connector type A
Console
Electrical specification LVTTL/LVCMOS-level Data rate 115.2 kbit/s Data format 8 data bits, no parity, 1 stop bit, no flow control Circuit type SELV Connection 2.5 mm jack, use only Westermo cable 1211-2027
RJ-45 connector (Front view)
Male Female
Pin 8
Pin 1
Pin 1
Pin 8
Pin 8 Pin 1
Page 11
11
6643-2230
Location of interface ports and LED’s
LED Indicators (for details see page 14)
Power connection (for details see page 9 and 13)
I/O connection (for details see page 10 and 13)
USB
Position Direction Description
No. 1 Out VBUS
No. 2 In/Out D–
No. 3 In/Out D+
No. 4 Out GND
Shield In/Out Connected to protective earth
RS-232
Position Signal Direction Description
No. 1 DSR Out Data Set Ready
No. 2 DCD Out Data Carrier Detect
No. 3 DTR In Data Terminal Ready
No. 4 SG Signal Ground, not chas-
sis ground
No. 5 RD Out Receive Data
No. 6 TD In Transmit Data
No. 7 CTS Out Clear To Send
No. 8 RTS In Request To Send
Ethernet connection TX (4 ports)
Position Signal Direction Description
No.1 TD+ In/Out Transmitted/Received data
No. 2 TD– In/Out Transmitted/Received data
No. 3 RD+ In/Out Transmitted/Received data
No. 4 Not Connected
No. 5 Not Connected
No. 6 RD– In/Out Transmitted/Received data
No. 7 Not Connected
No. 8 Not Connected
Shield Connected to PE
Page 12
12
6643-2230
Connection to console port
The console port can be used to connect to the CLI (Command Line Interface).
The following steps needs to be taken
1. Connect the serial diagnostic cable to the console port (use only Westermo cable 1211-2027).
2. Connect cable to your computer (USB port, if drivers are needed they can be downloaded from our Web page).
3. Use a terminal emulator and connect with correct speed and format (115200, 8N1) to the assigned port.
For more information about the CLI, see the WeOS management guide.
I/O connection (for details see page 10)
Console port (for details see page 10)
Cable 1211-2027
Bottom view
Accessories
Description Art no
Westermo console cable 1211-2027
RJ45 to terminal block 1200-2490
RJ45 to DB9 cable 1211-2210
Page 13
13
6643-2230
Power connection
I/O connection
1
2
3
4
4-position Product marking Direction Description
No. 1 +DC1 Input Supply voltage input DC1
No. 2 +DC2 Input Supply voltage input DC2
No. 3 -COM Input Common
No. 4 -COM Input Common
LynxDSS supports redundant power connection. The positive inputs are +DC1 and +DC2, the negative input for both supplies are –COM. Connect the primary voltage (e.g. +24 VDC) to the +DC1 pin and return to one of the –COM pins on the power input.
1
2
3
4
4-position Product marking Direction Description
No. 1 Status + Output Alarm relay (status) contact
No. 2 Status – Output Alarm relay (status) contact
No. 3 Digital in + Input Digital in +
No. 4 Digital in – Input Digital in –
The Status output is a potential free, opto-isolated normally closed solid-state relay. This can be configured to monitor various alarm events within the Lynx DSS unit, see WeOS Management Guide. An external load in series with an external voltage source is required for proper functionality. For voltage/current ratings, see Interface Specification section.
The Digital in is an opto-isolated digital input which can be used to monitor external events. For volt­age/current ratings, see Interface Specification section:
Lynx DSS
External Load
Status
V
V
Digital In
+
1
2
3
4
Page 14
14
6643-2230
LED indicators
LED Status Description
ON OFF Unit has no power.
GREEN All OK, no alarm condition.
RED Alarm condition, or until unit has started up.
(Alarm conditions are configurable, see ''WeOS Management Guide'').
BLINK Location indicator ("Here I am!"). Activated when
connected to IPConfig Tool, or upon request from Web or CLI.
DC1
OFF Unit has no power.
GREEN
Power OK on DC1.
RED Power failure on +DC1.
DC2 OFF Unit has no power.
GREEN Power OK on DC2.
RED Power failure on +DC2.
FRNT OFF FRNT disabled.
GREEN FRNT OK.
RED FRNT Error.
BLINK Unit configured as FRNT Focal Point.
RSTP
OFF RSTP disabled.
GREEN RSTP enabled.
BLINK Unit elected as RSTP/STP root switch.
USR1 OFF
Configurable, see WeOS Management Guide.GREEN
RED
Rx/TD, TD OFF No serial data received.
GREEN FLASH
Serial data received.
Tx/RD, RD OFF No serial data transmitted.
GREEN FLASH
Serial data transmitted.
1 to 4 OFF No Link.
GREEN Link established.
GREEN FLASH
Data traffic indication.
YELLOW Port alarm and no link. Or if FRNT or RSTP mode,
port is blocked.
Page 15
15
6643-2230
Mounting
This unit should be mounted on 35 mm DIN-rail, which is horizontally mounted inside an apparatus cabinet or similar. It is recommended that the DIN-rail is connected to ground. Snap on mounting, see figure.
Mounting Lynx with integrated DIN-clip:
Removal
Cooling
This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Minimum spacing 25 mm (1.0 inch) above / below and 10 mm (0.4 inches) left / right the unit. Spacing is recommended for the use of unit in full operating temperature range and service life.
10mm 10mm
Removing Lynx with integrated DIN-clip: Press down the support at the back of the unit using a screwdriver. See figure.
Page 16
16
6643-2230
Getting Started
This product runs Westermo Operating System (WeOS) which provides several management tools that can be used for configuration of the unit.
• IPConfig tool
This is a custom Westermo tool used for discovery of attached Westermo units.
Note! Version of IP Config tool must be 10.4.0 or higher.
• Web
Configuration of the unit using the web browser.
• CLI Configuration of the unit via the Command Line Interface.
Username: admin Password: westermo
If the computer is located in the same subnet as the switch you can easily use a web browser to configure the unit. Within the web you can configure most of the available functions.
For advanced network settings and more diagnostic information, please use the CLI. Detailed documentation is available in the chapter The Command Line Management Tool in the WeOS management guide.
Factory default IP address: 192.168.2.200 Netmask: 255.255.255.0 Gateway: Disabled
Note! If you are not sure about the subnet – consult your network administrator.
Configuration
Configure the unit via Web browser
The unit can easily be configured via a Web browser. Open the link http://192.168.2.200 in your web browser, and you will be prompted with a Login screen, where the default settings for Username and Password are:
Username: admin Password: westermo
Once you have logged in, you can use the extensive integrated help function describing all configuration options. Two common task when configuring a new switch is to assign appropriate IP settings, and to change the password of the admin account. The password can be up to 64 characters long, and should consist of printable ASCII characters (ASCII 33-126); 'Space' is not a valid password character.
Page 17
17
6643-2230
Factory default on Lynx L105-S1 and L205-S1
It is possible to set the unit to factory default settings by using two straight standard Ethernet RJ-45 cables.
1. Power off the switch and disconnect all Ethernet cables (copper and fibre).
2. Connect one Ethernet cable between Ethernet ports 1 and 4, and the other between Ethernet ports 2 and 3. The ports need to be connected directly by an Ethernet cable, i.e., not via a hub or switch. Use a straight cable – not a cross-over cable – when connecting the ports.
3. Power on the unit.
4. Wait for the unit to start up. Control that the ON LED is flashing red. The ON LED flashing indicates that the unit is now ready to be reset to factory default. You now have the choice to go ahead with the factory reset, or to skip factory reset and boot as normal.
• Go ahead with factory reset:
Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cables. The ON LED will stop flashing. This initiates the factory reset process*, and the unit will restart with factory default settings. When the switch has booted up, the ON LED will show a green light, and is now ready to use.
• Skip the factory reset:
To skip the factory reset process, just wait for approximately 30 seconds (after the ON LED starts flashing RED) without unplugging the Ethernet cables. The switch will conduct a normal boot with the existing settings.
* Note Do not power off the unit while the factory reset process is in progress.
Referring documents
Type Description Document number
Management Guide Westermo OS management guide
6101-3201
Page 18
Page 19
Page 20
REV. E 6643-2230 2016-05 Westermo Teleindustri AB, Sweden
For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code
China sales.cn@westermo.com www.cn.westermo.com
France infos@westermo.fr www.westermo.fr
Germany info@westermo.de www.westermo.de
North America info@westermo.com www.westermo.com
Singapore sales@westermo.com.sg www.westermo.com
Sweden
info.sverige@westermo.se www.westermo.se
United Kingdom sales@westermo.co.uk www.westermo.co.uk
Other Offices
Sales Units
Westermo Data Communications
Westermo • SE-640 40 Stora Sundby, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
E-mail: info@westermo.com
www.westermo.com
Loading...