Westermo DDW-221 User Manual

User Guide
6642-22102
WOLVERINE SERIES
DDW-221
©
Westermo Teleindustri AB
Industrial Ethernet SHDSL extender
www.westermo.com
Legal information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
http://www.westermo.com
2
2
6642-22102
6642-22102
Safety
Before installation:
!
Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe oper­ating specifications for this unit.
This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is
restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be
possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.
This unit uses convection cooling. To avoid obstructing the airflow around the unit, follow the spacing recommendations (see Cooling section).
Before mounting, using or removing this unit:
!
Prevent access to hazardous voltage by disconnecting the unit from power supply. Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations.
This unit must not be operating with removed covers or lids. Do not attempt to disassemble the unit. There are no user serviceable parts inside. Do not drop, knock or shake the unit, rough handling above the specification may cause
damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not paint the unit. Paint can clog the unit and prevent proper operation. Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not water-
proof. Keep the unit within the specified humidity levels. Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical
part may be damaged. If the unit is not working properly, contact the place of purchase, nearest Westermo dis-
tributor office or Westermo Tech support. A readily accessible disconnect device shall be incorporated external to the equipment. This unit may have hot surfaces when used in high ambient temperature. WARNING – SUBSTITIUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR
DIVISION 2
WARNING – DO NOT OPEN WHEN ENERGIZED WARNING – DO NOT DISCONNECT EQUIPMENT UNLESS AREA IS KNOWN TO
BE NONHAZARDOUS
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
6642-22102
6642-22102
3
3
ATEX Information
General
This unit is intended to be used in Zone 2 hazardous location only.
Marking
II 3G EEx nA II T4 SPECIAL CONDITION
The Ex mark (Epsilon X mark) is a specific marking for explosive protection equipment. The mark shows that this unit complies with the requirements of the relevant European standards that are harmonised with the 94/9/EC Directive.
Equipment group II.
II
3G
EEx
nA
II
T4
SPECIAL
CONDITON
This unit can be installed in all places with an explosive gas atmosphere other than mines susceptible to firedamp.
Category 3G. A category is the classification according to the required level of protection. This unit is intended for use in areas in which explosive atmosphere caused by gases, vapours or mists are unlikely to occur or, if they do occur, are likely to do so only infrequently and for a short period only. Equipment in this category ensures the requisite level of protection during normal operation. The letter 'G' indicates the protection concerning explosive atmospheres caused by gases, vapours or mists.
The marking of "EEx" shows that this unit is in conformity with European Ex standard(s).
Type of protection applied to electrical equipment to avoid ignition of a surround­ing explosive atmosphere. This unit is a non-sparking device "nA" which is constructed to minimize the risk of occurrence of arcs or sparks capable of creating an ignition hazard during con­ditions of normal operation.
Equipment group II. This unit can be installed in all places with an explosive gas atmosphere other than mines susceptible to firedamp.
Temperature class T4. This unit is classified in accordance with its maximum surface temperature (external and internal).
This unit have special condition for use. The special conditon for use containes safety related information that is necesarry for the correct installation and safe use.
4
6642-22102
Special condition for use
Ambient temperature:
This unit is designed for use in extreme ambient temperature conditions according to the following: –40 ºC ≤ T
+70 ºC
amb
Degree of protection by enclosure (IP):
This unit is intended for installation in an apparatus cabinet or similar providing adequate protection against the entry of solid foreign objects or water capable of impairing safety. The unit shall attain an equivalent degree of protection of IP54 by the installation in the apparatus cabinet or similar.
Resistance to impact:
This unit is intended for installation in an apparatus cabinet or similar, where the appara­tus cabinet provides the adequate resistance to impact.
Resistance to light:
This unit is intended for installation in an apparatus cabinet or similar where it is pro­tected from light (for example daylight or light from luminaries).
Conductor temperature:
When this unit is installed in locations with high ambient temperature, special precautions shall be taken upon the choice of external conductors and the temperature rating of the conductor(s).
Directive 94/9/EC alongside with other directives:
Directive 2004/108/EC (EMC) applies and to assure a safe performance of this unit under the scope of Directive 94/9/EC, refer to the electromagnetic immunity level specified under Type tests and environmental conditions in this manual.
Standards and date of compliance
EN 60079-0 and EN 60079-15 2008-11-01
6642-22102
5
Agency approvals and standards compliance
Type
Approved
Agency/ W-mo
Approval / Compliance
EMC W-mo EN 61000-6-2, Immunity industrial environments
W-mo EN 55024, Immunity IT equipment
W-mo EN 61000-6-4, Emission industrial environments
W-mo FCC part 15 Class A
W-mo EN 50121-4, Railway signalling and telecommunications
apparatus
Safety W-mo EN 60950-1, IT equipment
SHDSL NEMKO ITU-T G.991.2
EX FM Approvals Class 1, Division 2
ATEX W-mo EN 60079-0 and EN 60079-15
FCC Part 15.105 Notice:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a partic­ular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
… Reorient or relocate the receiving antenna … Increase the separation between the equipment and receiver … Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected
… Consult the dealer or an experienced radio/TV technician for help.
6
6642-22102
Declaration of Conformity
Westermo Teleindustri AB
Declaration of conformity
The manufacturer
Herewith declares that the product(s)
Type of product Model Art no From serial no.
DIN-rail Wolverine series DDW-22x 3642-02xx 2000
is in conformity with the following EC directive(s).
No Short name
2004/108/EC Electromagnetic Compatibility (EMC) 94/9/EC Equipment explosive atmospheres (ATEX)
References of standards applied for this EC declaration of conformity.
No Title Issue
EN 61000-6-2 Immunity for industrial environments 2005 EN 61000-6-1 Immunity for residential, commercial and light-
EN 55024 Information technology equipment – Immunity 1998 + A1:2001
EN 50121-4 Railway applications – Electromagnetic compatibility
EN 61000-6-4 Emission standard for industrial environments 2007 EN 60079-0 Electrical apparatus for explosive gas atmospheres –
EN 60079-15 Electrical apparatus for explosive gas atmospheres –
Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden
industrial environments
– Emission and Immunity of the signalling and telecommunications apparatus
General requirements
Construction, test and marking of type of protection “n” electrical apparatus
2007
+ A2:2003 2006
2006
2005
The last two digits of the year in which the CE marking was affixed: 08
Pierre Öberg Technical Manager 1st November 2008
Org.nr/ Postadress/Postal addres s
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
6642-22102
Tel.
Telefax
Postgiro
Bankgiro
Corp. identity number Registered office
7
Type tests and environmental conditions
Phenomena Test Description Test levels
ESD EN 61000-4-2 Enclosure contact ± 6 kV
Enclosure air ± 8 kV
RF field AM modulated IEC 61000-4-3 Enclosure 20 V/m 80% AM (1 kHz), 80 – 1000 MHz
10 V/m 80% AM (1 kHz), 1400 – 2100 MHz 5 V/m 80% AM (1 kHz), 2100 – 2500 MHz 1 V/m 80% AM (1 kHz), 2500 – 2700 MHz
Fast transient EN 61000-4-4 Signal ports ± 2 kV
Power ports ± 2 kV
Surge EN 61000-4-5 Signal ports balanced ± 2 kV line to earth, ± 1 kV line to line
Power ports ± 2 kV line to earth, ± 2 kV line to line
RF conducted EN 61000-4-6 Signal ports 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power frequency mag­netic field
Pulse magnetic field EN 61000-4-9 Enclosure 300 A/m Mains freq. 50 Hz EN 61000-4-16 Signal ports 100 V 50 Hz line to earth Mains freq. 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Voltage dips and inter-
ruption
Radiated emission
Conducted emission EN 55022 DC power ports Class B Dielectric strength EN 60950 Signal port to other
Temperature Operating -40 to +70ºC
Humidity Operating 5 to 95% relative humidity
Altitude Operating 2 000 m / 70 kPa Reliability prediction
(MTBF) Vibration IEC 60068-2-6 Operating 7.5 mm, 5 – 8 Hz 2 g, 8 – 500 Hz Shock IEC 60068-2-27 Operating 15 g, 11 ms Enclosure UL 94 Aluminium/Zink Flammability class V-0 Dimension W x H x D 134 x 105 x 122 mm Weight 1.5 kg Degree of protection IEC 529 Enclosure IP40 Cooling Convection Mounting Horizontal on 35 mm DIN-rail
EN 61000-4-8 Enclosure 300 A/m
EN 61000-4-29 DC power ports 10 & 100 ms, interruption
10 ms, 30% reduction 10 ms, 60% reduction +20% above & –20% below rated voltage
EN 55022 Enclosure Class A
FCC part 15 Class A
1500 Vrms 50 Hz 1 min
isolated ports Power port to other isolated
ports
Storage & Transport -40 to +70ºC Maximum surface temperatur 135 ºC (temperatur class T4)
Storage & Transport 5 to 95% relative humidity
MIL-HDBK- 217F Operating 700 000 hours @ 25°C
1500 Vrms 50 Hz 1 min
8
6642-22102
Description
The DDW-221 is an Industrial Ethernet SHDSL extender with support for redundancy. The redundant protocol can be used ether on the SHDSL interface or on the built-in Ethernet switch. Our unique FRNT (Fast Recovery of Network Topology) technology is the fastest pro­tocol on the market to re-configure a network in the event of any failure of a link or hardware. SHDSL represents the best of several symmetric DSL technologies. This unit provides the ability to reuse existing twisted copper pair with data rates from 192 kbit/s to 5.7 Mbit/s in both directions. The DDW-221 makes it possible to communicate over 10 km (6.2 miles) on twisted pair cable. The DDW-221 is a bridge not router and so is simple to install. All configuration is done using a web interface. The DIN rail mounted DDW-221 is designed for harsh environments and can be used in industrial and railway applications. It can be powered from two separate supplies and handle an operating voltage range of 16 – 60 VDC.
Redundant protocol (FRNT) on SHDSL or on the Ethernet switch 192 kbit/s to 5.7 Mbit/s Over 10 km (6.2 miles) on twisted pair Daisy chain SHDSL applications Wide temperature range (–40 to +70°C) (–40 to 158°F) Total galvanic isolation & transient protection Industrial and Rail EMC approvals Redundant power and wide DC input range Configuration using web interface Integrated 4-port Ethernet switch with 10/100Base-TX Auto MDI/MDI-X Auto speed on SHDSL with reliable, normal or high-speed mode Comprehensive statistics
SHDSL
Ethernet
SNMP support Extensive line protection with over-current / voltage suppression
Diagram showing speed versus distance
DDW-221 @ 0.5 mm
Speed bit/s Distance metre / miles Distance metre / miles
192000 10000 / 6.21 6450 / 4.00
1024000 7650 / 4.75 4850 / 3.01
1280000 7050 / 4.38 4700 / 2.92
2304000 5950 / 3.69 4150 / 2.58
3328000 4900 / 3.04 3700 / 2.30
4544000 4250 / 2.64 3150 / 1.95
5696000 3650 / 2.26 2800 / 1.73
Distance is tested without noise.
6642-22102
2
DDW-221 @ 0.4 mm
2
9
Interface specifications
Power
Rated voltage 20 to 48 VDC Operating voltage 16 to 60 VDC Rated current 300 mA @ 20 VDC
150 mA @ 48 VDC
Rated frequency DC
2
Inrush current, I Startup current* 400 mA Polarity Reverse polarity protected Redundant power input Yes Isolation to Ethernet, SHDSL Connection Detachable screw terminal Connector size 0.2 – 2.5 mm Shielded cable Not required
* If external power supply is used it must meet specified inrush current.
SHDSL
t 3.1 A2s
2
(AWG 24 – 12)
Electrical specification ITU-T G.991.2 Annex B Data rate 192 kbit/s to 5696 kbit/s Protocol EFM according to IEEE 802.3-2004 Transmission range According to ITU-T G.991.2 depending on the line quality Protection Overcurrent / overvoltage protection circuit and varistor Isolation to Power, Ethernet Connection Detachable screw terminal
2
Connector size 0.2 – 2.5 mm
(AWG 24 – 12) Shielded cable Not required Number of ports 2
Ethernet TX
Electrical specification IEEE std 802.3 2000 Edition Data rate 10 Mbit/s, 100 Mbit/s, manual or auto Duplex Full or half Transmission range 100 m / 328 ft Isolation to Power, SHDSL Connection RJ-45 Shielded cable Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close to rails**
Number of ports 4 ports marked as 1, 2, 3, 4
** To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary to the rails and connected to this port.
10
6642-22102
Connections
DSL screw connector 1 & 2
Position Direction Description
1 In/Out 2-wire Receive/ Transmit SHDSL 2 In/Out 2-wire Receive/ Transmit SHDSL
Earth connect
LED indicators (for details see next page)
II 3G EEx nA II T4
LED indicators (for details see next page)
integrated in RJ-45 connector.
(for details see next page)
Ethernet TX connection
LED indicators, also
Power connection
Position Direction* Description
1 In + Voltage A
2 In + Voltage B
3 In Common
4 In Common
* Direction relative this unit ** To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary to the rails and connected to this port. The cable shield should be properly connected (360°) to an earthing point within 1 m from this port. This earthing point should have a low impedance connection to the con­ductive enclosure of the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing system of an installation and may be directly connected to the protective earth.
1 2 3 4
(RJ-45 connector) 1 – 4**
Position Direction* Description
1 In/Out TD+
2 In/Out TD– 3 In/Out RD+ 4 Not Connected 5 Not Connected 6 In/Out RD– 7 Not Connected 8 Not Connected
CAT 5 cable is recommended. Unshielded (UTP) or shielded (STP) connectors can be used.
6642-22102
11
LED indicators
LED Status Description
PWR OFF No power
ON (green) Booting ready, unit ready
ON (red) Unit is booting
FRNT OFF FRNT disabled
ON (green) FRNT enabled and unit is ring
member, ring ok
Flashing (green) FRNT enabled and unit is focal point,
ring ok
Flashing (red) FRNT error and unit is focal point,
ring broken
ON (red) FRNT error according
to the following
1. If unit is ring member at least one trunk port is down
2. If unit is focal point ring is not intact
10/100BASE-TX Port 1 – 4 Green LED
10/100BASE-TX Port 1 – 4 Yellow LED
DSL Port 1 – 2
OFF No link
ON Link active
Flashing Traffic on link
OFF No port alarm
ON Port alarm
OFF No link
ON (green) Link established
ON (red) Unit is booting
Flashing (green) Link negotiation
Flashing (red)) Downloading firmware to DSL chip
12
6642-22102
Daisy chain SHDSL connection
DDW-221
DDW-221
DDW-221
Connect DDW-120 to DDW-22x
In an SHDSL connection one unit shall be configured as CO (Central Office) and one as CPE (Customer Premises Equipment). DDW-22x factory default is, DSL1 configured as CPE and DSL2 configured as CO.
Redundant SHDSL connection
The DDW-221 are available with redundant ring technology. This eliminates network failure caused by communication failures on the ring ports. In a ring application one unit must be configured as focal point, all other units will be con­figured as members.
Connect DSL 1 to DSL 2 on the following units to obtain a chain of linked units.
DDW-221
DDW-221
DDW-221
DDW-221
6642-22102
13
Configuration
The unit can easily be configured via the onboard Web based configuration tool. Local IP addresses can also be configured by using the Westermo IP Config too. From the IP Config tool it is then possible to browse into the unit for further configuration.
IP Address
When delivered, the default IP address of the DDW-2XX is 192.168.2.200. The default gateway is 192.168.2.200 If the default address of the unit is valid in the connected network it is possible to access the unit directly from a web browser.
Change local IP address
The local address of DDW-2XX can be configured using the IP Configuration tool. The IP Configuration program is available on the CD or for download from the WESTERMO web page: http://www.westermo.com, (choose Downloads/Software/ Ethernet/Ethernet switches/)
Name: setup.exe Install the software and start the application from a PC on the network connected to
where the DDW-2XX is installed. Make sure that the Default IP of the configuration soft­ware (see figure below) is in the same subnet as your PC.
Note! If you are not sure about the subnet – consult your network administrator. Note! IP Config version must be 10.0.0 or higher.
IP configuration
Device list:
IP Adress
192.168.2.200 255.255.255.0 00-07-7C-80-4A-6C 9.74 DDW-221
Scan for switches
Subnet Mask
Default IP:
192. 168. 2. 60
MAC Adress SW Ver Type Status
Mask:
255. 255. 255. 0
Help About
Close
Note! If you are not sure about the settings
- consult your network administrator.
Figure 1
14
6642-22102
By clicking the Scan for switches button the IP Configuration Software will detect the Westermo switches on the network. The software will list all Westermo managed switch­es or routers connected to the network. Information as in figure 1 will appear for each detected unit connected to the same network as your PC. If you only want to change the IP address and the subnet mask, this can be done within the IP config tool.
IP configuration
Access switch via web?
CancelOK
1. Click the listed DDW-2XX that you wish to re-configure.
2. A pop-up screen will show with the message “Access switch via web”.
Figure 2
Click Cancel, figure 2.
3. Enter the preferred IP address, Subnet mask and IP gateway address, figure 3. Click Set-button to confirm the settings in the unit, figure 3. Click the Scan for switches button again and the settings you configured will appear in
the list. Now you can access the DDW-2XX via the browser for further configuration by clicking the unit with an IP address that fits your subnet. Figure 2 will appear and now you click the OK button and a web browser will be opened and redirected to the DDW­2XX unit login page, figure 5.
Selected Device
Click the Close button to get back to main view. You will then be asked if you would like to quit.
DDW-221 configuration
192
IP adress:
Subnet mask:
MAC adress:
Host name:
Location:
IP gateway adress:
Set Close
IP configuration
You have set new parameters on the switch. The switch must be restarted in order for the new parameters to take effect (except IP address change). Type cancel to return to selected dialog or OK if you still want to quit.
168 2 200
255 255 0
255
00 07 7C 80 4A 6C
Westermo
location 192 168 2 200
CancelOK
Click the OK button, figure 4, and you will be back to the main view of the IP Configuration program (see figure 1).
Figure 3
Figure 4
6642-22102
15
Westermo - location - Provided by Westermo
http://192.168.2.220/conf/p.cgi
File Edit View Favorites Tools Help
Westermo - location
Login
Username:
Password:
Log in via Web
You will be prompted with a Login screen where the default settings for Username and Password are: Username: admin Password: westermo
Login
Done
Figure 5
The unit can be easily configured via the on-board Web based configuration tool. The network interface and switch properties can be configured and stored. The Web tool also has an extended integrated help function describing all configuration options.
Note! Max 10 characters can be used in the login.
Note! For login the following characters are not valid.
ASCII 34 = " ASCII 35 = # ASCII 39 = ’’ ASCII 40 = ( ASCII 92 = \
Simple Network Management Protocol (SNMP)
The DDW-2XX supports Simple Network Management Protocol version 1 and 2c (SNMPv1 and SNMPv2c). SNMP is an Internet standard protocol (IP) developed to manage IP nodes (servers, workstations, routers, switches and hubs etc.) on an Ethernet network.
SNMP enables network administrators and control engineers to manage network performance, find and solve network problems, and plan for network growth.
The DDW-2XX MIB’s are divided into groups allowing the SNMP manager to poll the SNMP agents for information.
16
6642-22102
Factory default
It is possible to set the unit to factory default settings by using two Ethernet cables and connect to the unit.
To set the unit to factory default do the following:
1. Connect Ethernet cable from port 1 to port 4.
2. Connect Ethernet cable from port 2 to port 3.
3. Power up the unit.
4. Wait for the unit to start up. Control that the PWR led is flashing green. The PWR flashing indicates that the unit will be set to factory default.
5. Remove the Ethernet cables, the unit will automatically start with factory default settings.
Note! The Ethernet cables must be removed within 30 seconds from power up
or the unit will do a normal start up.
6642-22102
17
Mounting
This unit should be mounted on 35 mm DIN-rail, which is horizontally mounted inside an apparatus cabinet or similar. Snap on mounting, see figure.
35 mm DIN-rail shall be mounted with a maximum distance of 70 mm between the mounting points.
This unit can also be wall-mounted, see figure.
POWER
CLICK!
PWR FRNT
DSL 1DSL 2
10/100 BASE-TX
DSL 1
1
DSL 2
2
3
4
Cooling
This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Minimum spacing 25 mm (1.0 inch) above /below the unit. Spacing is recommended for the use of unit in full operating temperature range and service life.
Removal
Press down the support at the back of the unit using a screwdriver. See figure.
POWER
25 mm
PWR FRNT
DSL 1DSL 2
10/100 BASE-TX
DSL 1
1
DSL 2
2
3
4
POWER
PWR
FRNT
DSL 1DSL 2
10/100 BASE-TX
DSL 1
1
DSL 2
2
3
4
25 mm
18
6642-22102
Westermo Teleindustri AB • SE-640 40 Stora Sundby, Sweden
Phone +46 16 42 80 00 Fax +46 16 42 80 01
E-mail: info@westermo.se
Westermo Web site: www.westermo.com
Subsidiaries
Westermo Data Communications AB Svalgången 1 SE-724 81 Västerås Phone: +46 (0)21 548 08 00 • Fax: +46 (0)21 35 18 50 info.sverige@westermo.se
Westermo Data Communications Ltd Talisman Business Centre • Duncan Road Park Gate, Southampton • SO31 7GA Phone: +44(0)1489 580-585 • Fax.:+44(0)1489 580586 E-Mail: sales@westermo.co.uk
Westermo Data Communications GmbH Goethestraße 67, 68753 Waghäusel Tel.: +49(0)7254-95400-0 • Fax.:+49(0)7254-95400-9 E-Mail: info@westermo.de
Westermo Teleindustri AB have distributors in several countries, contact us for further information.
Westermo Data Communications S.A.R.L. 9 Chemin de Chilly 91160 CHAMPLAN Tél : +33 1 69 10 21 00 • Fax : +33 1 69 10 21 01 E-mail : infos@westermo.fr
Westermo Data Communications Pte Ltd 2 Soon Wing Road #08-05 Soon Wing Industrial Building Singapore 347893 Phone +65 6743 9801 • Fax +65 6745 0670 E-Mail: sales@westermo.com.sg
REV.C 6642-22102 2009.11 Westermo Teleindustri AB, Sweden