Type tests and environmental conditions
Electromagnetic Compatibility
Environmental
phenomena
Basic
standard
Description Test levels
ESD EN 61000-4-2
Enclosure contact ± 6 kV
Enclosure air ± 8 kV
Fast transients EN 61000-4-4
Power port ± 2 kV
Ethernet ports ± 2 kV
SHDSL ports ± 2 kV
RS-232 port ± 2 kV
Status out / Digital in ± 2 kV
Earth port ± 1 kV
Surge EN 61000-4-5
Power port L-L: ±0.5 kV, 2 Ω, 18 μF
L-E: ±0.5 kV, 12 Ω, 9 μF
L-E: ±2 kV, 42 Ω, 0.5 μF
L-L: ±1 kV, 42 Ω, 0.5 μF
Ethernet ports L-E: ±2 kV, 2 Ω
SHDSL ports L-E: ±2 kV, 42 Ω, 0.5 μF
RS-232 port L-E: ±2 kV, 2 Ω
Status out / Digital in L-E: ±2 kV, 42 Ω, 0.5 μF
Pulse magnetic field EN 61000-4-9
Enclosure 300 A/m
Radiated RF immunity EN 61000-4-3
Enclosure 20 V/m 80% AM, 1 kHz sine, 80 – 1000 MHz
12 V/m 80% AM, 1 kHz sine, 1000 – 2700 MHz
10 V/m 80% AM, 1kHz sine, 2700 – 6000 MHz
Conducted RF
immunity
EN 61000-4-6
Power port 10 V, 80% AM, 1 kHz sine; 0.15 – 80 MHz
Ethernet ports 10 V, 80% AM, 1 kHz sine; 0.15 – 80 MHz
SHDSL ports 10 V, 80% AM, 1 kHz sine; 0.15 – 80 MHz
RS-232 port 10 V, 80% AM, 1 kHz sine; 0.15 – 80 MHz
Status out / Digital in 10 V, 80% AM, 1 kHz sine; 0.15 – 80 MHz
Earth port 10 V, 80% AM, 1 kHz sine; 0.15 – 80 MHz
Voltage dips
and interruption
EN 61000-4-29
DC Power port 10 ms, interruption
500 ms, 30% reduction
200 ms, 60% reduction
+20 above & –20% below rated voltage
Radiated RF emission CISPR 16-2-3
ANSI C63.4
(FCC part 15)
Enclosure Class B
Conducted RF
emission
CISPR 16-2-1
Power port Class B
Class B
Ethernet ports Class B
Class B
Dielectric strength EN 60950-1
Power port to other
isolated ports
2000 Vrms 50 Hz 1 min
Ethernet ports to all
other isolated ports
1500 Vrms 50 Hz 1 min
RS-232 port to all
other isolated ports
SHDSL ports to all
other isolated ports
Status out / Digital
in port to all other
isolated ports