Westermo Wolverine DDW-225, Wolverine DDW-225 EX, 3642-0240, 3642-5240, DDW-226 User Manual

...
www.westermo.com
©
Westermo Teleindustri AB
User Guide
6642-22303
Industrial Ethernet SHDSL extender
DDW-225
WOLVERINE SERIES
WeOS
2
6642-22303
Legal information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
http://www.westermo.com
Software tools
Related software tools are available in the folder software tools under technical support on the Westermo website.
3
6642-22303
Safety
Before installation:
Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.
This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is
restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be
possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.
This unit uses convection cooling. To avoid obstructing the airflow around the unit, follow the spacing recommendations (see Cooling section).
Before mounting, using or removing this unit:
Prevent access to hazardous voltage by disconnecting the unit from power supply. Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations.
This unit must not be operating with removed covers or lids. Do not attempt to disassemble the unit. There are no user serviceable parts inside. Do not drop, knock or shake the unit, rough handling above the specification may cause
damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not paint the unit. Paint can clog the unit and prevent proper operation. Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not
waterproof. Keep the unit within the specified humidity levels. Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical
part may be damaged. If the unit is not working properly, contact the place of purchase, nearest Westermo
distributor office or Westermo Tech support. A readily accessible disconnect device shall be incorporated external to the equipment. This unit may have hot surfaces when used in high ambient temperature.
WARNING:
When this unit is operated at an ambient temperature above +60°C, the External Surface of Equipment may exceed Touch Temperature Limit according to EN/IEC/UL 60950-1.
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
!
!
4
6642-22303
Type Approval / Compliance
EMC EN 61000-6-1, Immunity residential environments
EN 61000-6-2, Immunity industrial environments
EN 61000-6-3, Emission residential environments
EN 61000-6-4, Emission industrial environments
EN 50121-4, Railway signalling and telecommunications apparatus
Safety UL/IEC/EN 60950-1, IT equipment
SHDSL ITU-T G.991.2
Agency approvals and standards compliance
FCC Part 15.105 Notice:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
… Reorient or relocate the receiving antenna … Increase the separation between the equipment and receiver … Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected
… Consult the dealer or an experienced radio/TV technician for help.
5
6642-22303
Declaration of Conformity
Westermo Teleindustri AB
Declaration of Conformity
Org.nr/
Postadress/Postal address
Tel.
Telefax
Postgiro
Bankgiro
Corp. identity number Registered office
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
The manufacturer Westermo Teleindustri AB
SE-640 40 Stora Sundby, Sweden
Herewith declares that the product(s)
Type of product Models Art no Industrial Ethernet SHDSL extender Wolverine DDW-225
Wolverine DDW-225 EX
3642-0250
3642-5250 Wolverine DDW-226 Wolverine DDW-226 EX
3642-0240
3642-5240
is in conformity with the following EU directive(s).
No Short name 2014/30/EU Electromagnetic Compatibility (EMC)
2014/35/EU Low Voltage Directive (LVD) 2014/34/EU1 Equipment Explosive Atmospheres (ATEX) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment
(RoHS)
References of standards applied for this EU declaration of conformity.
No Title Issue EN 61000-6-1 Electromagnetic compatibility – Immunity for residential environments 2007
EN 61000-6-2
Electromagnetic compatibility – Immunity for industrial environments 2005
EN 61000-6-3
Electromagnetic compatibility – Emission residential environments 2007 EN 61000-6-4 Electromagnetic compatibility – Emission for industrial environments 2007 EN 50121-4 Railway applications – Electromagnetic compatibility – Emission and
immunity of the signalling and telecommunications apparatus
2015
EN 60950-1 Information technology equipment -- Safety -- General
requirements
2006 +A11: 2009
EN 60079-01 Explosive atmospheres Equipment – General requirements 2012 EN 60079-151 Electrical apparatus for explosive gas atmospheres –Construction, test
and marking of type of protection “n” electrical apparatus
2010
EN 50581 Technical documentation for the assessment of electrical and electronic
products with respect to the restriction of hazardous substances
2012
Pierre Öberg Technical Manager 9
t
h
March 2017
1
Only applicable for article no. 3642-5240, 3642-5250. Certificate: Baseefa14ATEX0151X. Issued by: SGS Baseefa
Limited, Rockhead Business Park, Staden Lane, Buxton, Derbyshire, SK17 9RZ, United Kingdom.
6
6642-22303
Type tests and environmental conditions
Phenomena Test Description Test levels
ESD EN 61000-4-2 Enclosure contact ± 6 kV
Enclosure air ± 8 kV
RF field AM modulated IEC 61000-4-3 Enclosure 20 V/m 80% AM (1 kHz), 80 – 2700 MHz
10 V/m 80% AM (1 kHz), 2700 – 6000 MHz
Fast transient EN 61000-4-4 Signal ports ± 2 kV
Power ports ± 2 kV
Surge EN 61000-4-5 Signal ports unbalanced ± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced ± 2 kV line to earth, ± 1 kV line to line Power ports ± 2 kV line to earth, ± 1 kV line to line
RF conducted EN 61000-4-6 Signal ports 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power frequency magnetic field
EN 61000-4-8 Enclosure 300 A/m
Pulse magnetic field EN 61000-4-9 Enclosure 300 A/m Mains freq. 50 Hz EN 61000-4-16 Signal ports 100 V 50 Hz line to earth Mains freq. 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Voltage dips
and interruption
EN 61000-4-29 DC power ports 10 ms, interruption
10 ms, 30% reduction 10 ms, 60% reduction +20% above & –20% below rated voltage
Radiated emission CISPR 16-2-3
ANSI C63.4 (FCC part 15)
Enclosure Class A and Class B, 30 – 1000 MHz Enclosure Class A and Class B, 30 – 1000 MHz
Conducted emission CISPR 16-2-1 DC power ports Class A and Class B Dielectric strength EN 60950 Signal port
to other isolated ports
1500 Vrms 50 Hz 1 min
Power port to other isolated ports
1500 Vrms 50 Hz 1 min
Temperature EN 60068-2-1
EN 60068-2-2
Operating –40 to +70ºC Storage & Transport –40 to +85ºC Maximum surface
temperature
135°C (temperature class T4)
Humidity EN 60068-2-30 Operating 5 to 95% relative humidity
Storage & Transport 5 to 95% relative humidity Altitude Operating 2 000 m / 70 kPa Reliability prediction
(MTBF)
MIL-HDBK-217F Operating 410 000 hours @ 25°C
Service life Operating 10 year Vibration IEC 60068-2-6 Operating 7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz Shock IEC 60068-2-27 Operating 15 g, 11 ms Enclosure UL 94 Aluminium/Zink Flammability class V-0 Dimension W x H x D 134 x 105 x 122 mm Weight 1.5 kg Degree of protection IEC 60529 Enclosure IP40