Westermo RFIR-227-F4G-T7G-DC, RFIR-127-F4G-T7G-AC, RFIR-219-F4G-T7G-DC, RFIR-219-F4G-T7G-AC, RFIR-227-F4G-T7G-AC User Manual

...
Page 1
Industrial Routing Switch
www.westermo.com
©
Westermo Teleindustri AB
User Guide
6641-22810
RedFox
SERIES
WeOS
Status-
Status+
Digital In-
Digital In+
Page 2
2
6641-22810
Legal information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused. More information about Westermo can be found at the following Internet address:
http://www.westermo.com
Software tools
Related software tools are available in the folder software tools under technical support on the Westermo website.
Page 3
3
6641-22810
Safety
Before installation:
Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations. This unit uses convection cooling. To avoid obstructing the airflow around the unit, follow the spacing recommendations (see Cooling section).
Before powering-up, a protective earthing conductor must be connected to the protective earthing terminal and have a cross-sectional area of at least 1.5 mm².
Before mounting, using or removing this unit:
Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply. Prevent access to hazardous voltage by disconnecting the unit from power supply.
Caution: Double pole/neutral fusing (AC models only)
Class 1 Laser Product. Do not look directly into fibre optical fibre port or
any connected fibre, although this unit is designed to meet the Class 1 Laser regulations. Complies with 21 CFR 1040.10 and 1040.11.
Caution: To reduce the risk of fire, use only No. 26 (e.g. 24 AWG) UL listed or CSA certified Telecommunication Line Cord.
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations. This unit must not be operating with removed covers or lids. Do not attempt to disassemble the unit. There are no user serviceable parts inside. Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not paint the unit. Paint can clog the unit and prevent proper operation. Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels. Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged. If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support. Fibre connectors are supplied with plugs to avoid contamination inside the optical port. As soon as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, the plug should be applied.
!
! !
! !
Page 4
4
6641-22810
Note. Fibre Optic Handling
Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the unit the protective hood on the transmitter/receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handle the same way.
If these recommendations are not followed the warranty might be jeopardized.
Cleaning of the optical connectors
In the event of contamination, the optical connectors should only be cleaned by the use of recommended cleaning fluids and correct cleaning equipment.
Recommended cleaning fluids:
• Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
• Hexane
• Naphtha
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
Page 5
5
6641-22810
Agency approvals and standards compliance
Art.no Model Type Approval/compliance
3641-4020 3641-4030 3641-4005 3641-4015 3641-4025 3641-4035
RFIR-127-F4G-T7G-DC RFIR-127-F4G-T7G-AC RFIR-219-F4G-T7G-DC RFIR-219-F4G-T7G-AC RFIR-227-F4G-T7G-DC RFIR-227-F4G-T7G-AC
EMC EN 50121-4, Railway applications –
Electromagnetic compatibility – Emission and immunity of the signalling and telecommunications apparatus
EN 55022, Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement
EN 55024, Information technology equipment – Immunity characteristics Limits and methods of measurement
EN 61000-6-1, Electromagnetic compatibility – Immunity for residential environments
EN 61000-6-2, Electromagnetic compatibility – Immunity for industrial environments
EN 61000-6-4, Electromagnetic compatibility – Emission for industrial environments
IEC 62236-4, Railway signalling and
telecommunications apparatus Safety UL/IEC/EN 60950-1, IT equipment Marine DNV GL rules for classification – Ships and
offshore units
DNV GL rules for classification
Type Temperature Humidity Vibration EMC Enclosure
RFIR-xxx-F4G-T7G-AC C B A A A/IP40
RFIR-xxx-F4G-T7G-DC D B A B A/IP40
FCC Part 15.105 Notice:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
EN 55022 Notice:
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Page 6
6
6641-22810
Safety control drawing
Position
Direction/ description
Input/Output values
Status+ IO / Status + Uin = 60 VDC max
Status-- IO / Status – Iin = 80 mA max
Digital In+ IO / Digital in + Uin = 60 VDC max
Digital In- IO / Digital in – Iin = 2.9 mA max
Position
Direction/ description
Output values
1 In / VBUS
U = 5 VDC max I = 100 mA max
2 In/out / D–
3 In/out / D+
4 Not connected
5 Functional earth
Degree of protection: IP 40
Ambient temperature: –40 °C to +70 °C (DC), –40 °C to +55 °C (AC)
Position
Direction/ description
Input/output values
1 In/out / BI_DA+
Per port: U = ± 1 V (4V/us) I = ± 20 mA
Data rate: 10/100/1000 Mbit/s
2 In/out / BI_DA–
3 In/out / BI_DB+
4 In/out / BI_DC+
5
In/out / BI_DC–
6 In/out / BI_DB–
7 In/out / BI_DD+
8 In/out / BI_DD–
Shield Functional earth
Galvanically isolated via signal transformers and capacitively isolated to GND/Functional earth through a 2kV 1000pF capacitor. See user manual for proven transient protection.
Status-
Status+
Digital In-
Digital In+
Position
Direction/ description
Output values
1 Out / VBUS
U
out
= 5 VDC max
I
out
= 500 mA max
2 In/out / D–
3 In/out / D+
4 GND
Shield Functional earth
Direction/ description
Input values
In / +DC1
Uin = (16 – 60) VDC Iin = 2.0 A@16 VDC* PIn = 32 W@16 VDC*
In / +DC2
In / COM
In / COM
DC Power supply AC Power supply
Direction/ description
Input values
In / P
Uin = (100–240) VAC, 50–60 Hz Iin = 360 mA@100 VAC**
In / N
In / NC
In /
+DC1
+DC2
COM
COM
DC
* RFIR-227-T7G-F4G-DC ** RFIR-227-T7G-F4G-AC
Page 7
7
6641-22810
1
5
6
7
8
2
3
4
Safety control drawing
Position Direction* / description Input/output values
Rx In / Receive port
Max 5 dBm
Tx Out / Transmit port
Position Direction* / description Input/output values
1 In/out / BI_DA+
Per port: U = ± 1 V (4V/us) I = ± 20 mA
Data rate: 100/1000 Mbit/s
2 In/out / BI_DA–
3 In/out / BI_DB+
4 In/out / BI_DC+
5 In/out / BI_DC–
6 In/out / BI_DB–
7 In/out / BI_DD+
8 In/out / BI_DD–
Shield Functional earth
Galvanically isolated via signal transformers and capacitively isolated to functional earth through a 2kV 1000pF capacitor. See user manual for proven transient protection.
* Direction relative this unit!
1
5
6
7
8
2
3
4
Position Direction* / description Input/output values
1 In/out / TD+
Per port: U = ± 1 V (4V/us) I = ± 20 mA
Data rate: 10/100 Mbit/s
2 In/out / TD–
3 In/out / RD+
4 Not connected
5
Not connected
6 In/out / RD–
7 Not connected
8 Not connected
Shield Functional earth
Galvanically isolated via signal transformers and capacitively isolated to functional earth through a 2kV 1000pF capacitor. See user manual for proven transient protection.
Page 8
8
6641-22810
Declaration of Conformity
Westermo Teleindustri AB
Declaration of Conformity
Org.nr/
Postadress/Postal address
Tel.
Telefax
Postgiro
Bankgiro
Corp. identity number Registered office
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
The manufacturer Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden
Herewith declares that the product(s)
Type of product Models1 Industrial Ethernet Switch for 19 inch Rack mounting
RFIR-x19-F4G-T7G-DC, RFIR-x27-F4G-T7G-DC RFIR-x19-F4G-T7G-AC, RFIR-x27-F4G-T7G-AC
is in conformity with the following EU directive(s).
No Short name 2014/30/EU Electromagnetic Compatibility (EMC)
2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment
(RoHS)
2014/35/EU Low Voltage Directive (LVD)
1
Model Differences: x = 1 or 2 and indicates Software Class
References of standards applied for this EU declaration of conformity.
No Title Issue EN 50121-4 Railway applications – Electromagnetic compatibility – Emission and
immunity of the signalling and telecommunications apparatus
2015
EN 55022 Information technology equipment – Radio disturbance characteristics –
Limits and methods of measurement
2010
EN 55024 Information technology equipment – Immunity characteristics
Limits and methods of measurement
2010
EN 61000-6-1 Electromagnetic compatibility – Immunity for residential environments 2007 EN 61000-6-2 Electromagnetic compatibility – Immunity for industrial environments 2005
EN 61000-6-4 Electromagnetic compatibility – Emission for industrial environments 2007
+A1:2011
EN 50581 Technical documentation for the assessment of electrical and electronic
products with respect to the restriction of hazardous substances
2012
EN 60950-1 Information technology equipment - Safety - Part 1: General
requirements
2006 +A11: 2009 +A1: 2010 +A12: 2011 +A2: 2013
The last two digits of the year in which the CE marking was affixed: 16
Pierre Öberg Technical Manager 22
nd
March 2016
Page 9
9
6641-22810
Type tests and environmental conditions
Phenomena Test Description Test levels
ESD EN 61000-4-2 Enclosure contact ± 6 kV
Enclosure air ± 8 kV
RF field AM modulated IEC 61000-4-3 Enclosure 20 V/m 80% AM (1 kHz), 80 – 2700 MHz
10 V/m 80% AM, 1kHz sine, 2700 – 6000 MHz
Fast transient EN 61000-4-4 Signal ports ± 2 kV
Power ports ± 2 kV
Surge EN 61000-4-5 Signal ports ± 2 kV line to earth, ± 1 kV line to line
Power ports ± 2 kV line to earth, ± 2 kV line to line
(AC models) ± 2 kV line to earth, ± 1 kV line to line (DC models)
RF conducted EN 61000-4-6 Signal ports 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power frequency magnetic field
EN 61000-4-8 Enclosure 300 A/m 0, 16.7, 50, 60 Hz
Pulse magnetic field EN 61000-4-9 Enclosure 300 A/m Radiated emission CISPR 16-2-3 Enclosure Class A
ANSI C63.4 (FCC part 15)
Enclosure Class B, 30 – 6500 MHz
Conducted emission EN 55022 AC and DC power
ports Telecommunication ports Class B
Class B
FCC part 15 AC and DC power
ports
Class B
Dielectric strength EN 60950 Signal port to other
isolated ports
1.5 kVrms 50 Hz 1 min
Power port to other isolated ports
1.5 kVrms 50 Hz 1 min
Temperature EN 60068-2-1
EN 60068-2-2
Operating -40 to +70ºC (DC models)
-40 to +55ºC (AC models) Storage & Transport -40 to +85ºC (all models) Maximum surface
temperature
135 °C (temperature class T4)
Humidity EN 60068-2-30 Operating 5 to 95% relative humidity
Storage & Transport 5 to 95% relative humidity
Altitude Operating 2 000 m / 70 kPa Service life Operating 10 years Vibration IEC 60068-2-6 Operating 7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz (19" rack mounting according to IEC 60297, DIN 41494)
Shock IEC 60068-2-27 Operating 15 g, 11 ms
(19" rack mounting according to IEC 60297, DIN 41494)
Enclosure UL 94 Aluminium / Zink Flammability class V-0 (all models)
Page 10
10
6641-22810
Description
The RFIR (RedFox Industrial Rack) is a high performance industrial Ethernet switch designed for high network traffic applications. Various port configurations are available that can be further customized with SFP transceivers. RFIR is powered by the Westermo WeOS network operating system.
RFIR is designed for 19” cabinet according to ETSI standard making it suitable for use in control room networks as well as for cabi¬nets installed along railway trackside or maritime installations. RFIR is designed to run efficiently from an AC or DC power supply, the unit is also equipped with configurable I/O fault contact that make it ideal for easy installation and monitoring in industrial applications.
RedFox Industrial Rack models
Westermo article number
Denomination Description
3641-4020 RFIR-127-F4G-T7G-DC
16 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP
DC power supply
3641-4030 RFIR-127-F4G-T7G-AC
16 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP
AC power supply
3641-4005 RFIR-219-F4G-T7G-DC
8 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP
DC power supply
3641-4015 RFIR-219-F4G-T7G-AC
8 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP
AC power supply
3641-4025 RFIR-227-F4G-T7G-DC
16 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP
DC power supply
3641-4035 RFIR-227-F4G-T7G-AC
16 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP
AC power supply
Page 11
11
6641-22810
Specification
Dimension W x H x D 480 x 43 x 258 mm
18.9 x 1.66 x 10.16"
Weight 3.8 kg
Degree of protection IP40 according to EN 60529
Cooling Convection
Mounting 19" rack or wall-mounted
Status-
Status+
Digital In-
Digital In+
Port number RFIR-219-F4G-T7G DC or AC
Port number all other models
Status-
Status+
Digital In-
Digital In+
Housing
Description
The RedFox Industrial Rack is designed for installation in 19” rack solutions according to ETSI standard with a shallow depth of 240 mm. RFIR can also be wall mounted as an installation option.
32
480
469
462
43
A
235
466
18 240
7,2 (4x)
411
440
7
4
DETAIL A
SCALE 1 : 1
REVISIONS
Rev
Description
Designer
Approved
Date
01
Created
PWM
TDN
2014-12-02
02
New surface treatment and new overlay.
FaÅn
TDN
2016-01-27
Page 12
12
6641-22810
Interface specifications
Status-
Status+
Digital In-
Digital In+
I/O USB
Console port
SFP slot, 100/1000 Mbit/s FX or 10/10/1000 Mbit/s TX ports
10/100 Mbit/s TX ports
Power
10/100/1000 Mbit/s TX ports
Power interface specifications
4-position Product marking Direction Description
No. 1 +DC1 Input Supply voltage input DC1
No. 2 +DC2 Input Supply voltage input DC2
No. 3 -COM Input Common
No. 4 -COM Input Common
DC power
AC power
4-position Product marking Direction Description
No. 1 P Input Power
No. 2 N Input Neutral
No. 3 NC Input No connection
No. 4 Input Funtional earth
1
2
3
4
1
2
3
4
Protective earth
Page 13
13
6641-22810
Power
Rated voltage AC models 100 to 240 VAC, 50-60 Hz
DC models 20 to 48 VDC
Operating voltage AC models 90 to 264 VAC, 47-63 Hz
DC models 16 to 60 VDC
Maximum nominal current consumption
RFIR-127-F4G-T7G-DC 1.0 (1.2*) A @ 24 VDC
0.47 (0.54*) A @ 48 VDC
RFIR-219-F4G-T7G-DC 0.93 (1.12*) A @ 20 VDC
0.38 (0.45*) A @ 48 VDC
RFIR-227-F4G-T7G-DC 1.0 (1.2*) A @ 24 VDC
0.47 (0.54*) A @ 48 VDC
RFIR-127-F4G-T7G-AC 380 mA @ 100 VAC 50 Hz
240 mA @ 240 VAC 60 Hz
RFIR-219-F4G-T7G-AC 350 mA @ 100 VAC 50 Hz
210 mA @ 240 VAC 60 Hz
RFIR-227-F4G-T7G-AC 380 mA @ 100 VAC 50 Hz
240 mA @ 240 VAC 60 Hz
Fuse rating
Component: U3, U18
All models 4A(T)***
Inrush current DC models 25 mA2 @ 24 VDC
165 mA2 @ 48 VDC
AC models 75 mA2 @ 110 VAC
340 mA2 @ 230 VAC
Startup current** All models 2x nominal current
Rated frequency AC models 50/60 Hz
DC models DC
Polarity AC models Not applicable
DC models Reverse polarity protected
Redundant power input AC models No
DC models Ye s
Isolation to All other
Connection Detachable screw terminal
Connector size All models 0.2 – 2.5 mm2
(AWG 24 – 12)
Shielded cable Not required
* With 500mA USB load
** External supply current capability for proper start-up
*** Denote time-delay fuse
Page 14
14
6641-22810
USB
Electrical specification USB 2.0 host interface
Data rate High speed 480mbit/s
Circuit type SELV
Maximum supply current 500 mA
Isolation to All other except Console
Connection USB receptacle connector type A
Conductive housing Ye s
Connection to console port
The console port can be used to connect to the CLI (Command Line Interface). The console connector is a micro USB cable that connects to a FTDI FT232R USB to serial converter internally. For drivers please see www.ftdichip.com and download the appropriate VCP driver.
Console
Electrical specification USB 2.0 device interface
Data rate High speed 480mbit/s
Circuit type SE LV
Maximum supply current 100 mA
Isolation to All other except USB
Galvanic connection to USB
Connection USB Micro-B connector in device mode
Console
USB
Page 15
15
6641-22810
RFIR-127-F4G-T7G DC and AC RFIR-227-F4G-T7G DC and AC
Slot 1
1 10/100/1000 Mbit/s, TX port
2 10/100/1000 Mbit/s, TX port
3 10/100/1000 Mbit/s, TX port
Slot 2
4 10/100 Mbit/s, TX port
5 10/100 Mbit/s, TX port
6 10/100 Mbit/s, TX port
7 10/100 Mbit/s, TX port
8 10/100 Mbit/s, TX port
9 10/100 Mbit/s, TX port
10 10/100 Mbit/s, TX port
11 10/100 Mbit/s, TX port
Slot 3
12 10/100/1000 Mbit/s, TX port
13 SFP slot
14 10/100/1000 Mbit/s, TX port
15 SFP slot
16 10/100/1000 Mbit/s, TX port
17 SFP slot
18 10/100/1000 Mbit/s, TX port
19 SFP slot
Slot 4
20 10/100 Mbit/s, TX port
21 10/100 Mbit/s, TX port
22 10/100 Mbit/s, TX port
23 10/100 Mbit/s, TX port
24 10/100 Mbit/s, TX port
25 10/100 Mbit/s, TX port
26 10/100 Mbit/s, TX port
27 10/100 Mbit/s, TX port
Network ports
RFIR-219-F4G-T7G DC and AC
Slot 1
1 10/100/1000 Mbit/s, TX port
2 10/100/1000 Mbit/s, TX port
3 10/100/1000 Mbit/s, TX port
Slot 2
4 10/100/1000 Mbit/s, TX port
5 SFP slot
6 10/100/1000 Mbit/s, TX port
7 SFP slot
8 10/100/1000 Mbit/s, TX port
9 SFP slot
10 10/100/1000 Mbit/s, TX port
11 SFP slot
Slot 3
12 10/100 Mbit/s, TX port
13 10/100 Mbit/s, TX port
14 10/100 Mbit/s, TX port
15 10/100 Mbit/s, TX port
16 10/100 Mbit/s, TX port
17 10/100 Mbit/s, TX port
18 10/100 Mbit/s, TX port
19 10/100 Mbit/s, TX port
Status-
Status+
Digital In-
Digital In+
Slot 1 Slot 2* Slot 3* Slot 4*
* Network ports at slot 2 and slot 3 differ between the different RFIR models. Slot 4 is only available in model RFIR-227-F4G­T7G DC and AC.
Page 16
16
6641-22810
Ethernet TX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, (1000 Mbit/s), manual or auto
Duplex Full or half, manual or auto
Circuit type TNV-1
Transmission range Up to 150 m with CAT5e cable or better
Isolation to All other
Connection RJ-45 auto MDI/MDI-X
Shielded cable Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close to rails*
Conductive housing Ye s
* NOTE! Railway installation close to the rails.
To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m boundary to the rails and connected to this port.
The cable shield should be properly connected (360°) to an earthing point within 1 m from this port. This earthing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing system of an installation and may be directly connected to the functional earth. Refer also to "Safety" section.
1
5
6
7
8
2
3
4
10/100/1000 Mbit/s, TX
Position Direction* Description
1 In/Out BI_DA+
2 In/Out BI_DA–
3 In/Out BI_DB+
4 In/Out BI_DC+
5 In/Out BI_DC-
6 In/Out BI_DB-
7 In/Out BI_DD+
8 In/Out BI_DD-
Shield In/Out Connected to
Functional earth
* Direction relative this unit.
10/100(/1000) Mbit/s, TX ports
10/100 Mbit/s, TX
Position Direction* Description
1 In/Out TD+
2 In/Out TD–
3 In/Out RD+
4 In/Out Not connected
5 In/Out Not connected
6 In/Out RD-
7 In/Out Not connected
8 In/Out Not connected
Shield In/Out Connected to
Functional earth
* Direction relative this unit.
Page 17
17
6641-22810
Position Direction* Description
Rx In Receive port
Tx Out Transmit port
* Direction relative this unit.
1
5
2
6
3
7
4
8
SFP ports
Optical/Electrical specification IEEE std 802.3 2005 Edition
Data rate 10, 100 or 1000 Mbit/s*
Duplex Full or half, manual or auto
Transmission range Depending on transceiver
Connection SFP slot holding fibre transceiver or copper transceiver
* 100 Mbit/s or 1000 Mbit/s transceiver supported.
SFP slot
Each SFP slot can hold one SFP transceiver for copper or fibre cable. Fibre transcievers distances range from 550 m (0.34 mi) to 120 km (74.6 mi). For supported transceivers, see SFP data sheet.
Page 18
18
6641-22810
I/O connection
Status+
Digital In-
Digital In+
Status-
Product marking Direction Description
Digital in – Input Digital in –
Digital in + Input Digital in +
Status – Output Alarm relay (status) contact
Status + Output Alarm relay (status) contact
The Status output is a potential free, opto-isolated normally closed solid-state relay. This can be configured to monitor various alarm events within the RFIR unit, see WeOS Management Guide. An external load in series with an external voltage source is required for proper functionality. For voltage/ current ratings, see Interface specification section.
The Digital in is an opto-isolated digital input which can be used to monitor external events. For voltage/current ratings, see Interface Specification section:
External Load
Status
V
V
Digital In
+
1
2
3
4
IO / Relay output
Connect resistance 30 W
Isolation to All other
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Maximum voltage/current 60 VDC / 80 mA
IO / Digital input
Voltage levels Vih > 8V Vil < 5V
Iin = 2.9mA @60V
Isolation to All other
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Maximum voltage 60 VDC
Page 19
19
6641-22810
LED indicators Power/CPU
LED Status Description
ON OFF Unit has no power.
GREEN All OK, no alarm condition.
RED Alarm condition, or until unit has
started up. (Alarm conditions are configurable, see ''WeOS Management Guide'').
BLINK Location indicator ("Here I am!").
Activated when connected to IPConfig Tool, or upon request from Web or CLI.
DC1 OFF Unit has no power.
GREEN Power OK on DC1.
RED +DC1 input voltage is below operating
voltage limit
DC2 OFF Unit has no power.
GREEN Power OK on DC2.
RED +DC2 input voltage is below operating
voltage limit
AC1 OFF Unit has no power
GREEN Power OK on AC1
FRNT OFF FRNT disabled.
GREEN FRNT OK.
RED FRNT Error.
BLINK Unit configured as FRNT Focal Point.
RSTP OFF RSTP disabled.
GREEN RSTP enabled.
BLINK Unit elected as RSTP/STP root switch.
USR1 Configurable, see WeOS Management Guide
TX/FX ports OFF No link.
GREEN Link established.
GREEN FLASH
Data traffic indication.
YELLOW Port alarm and no link. Or if FRNT or
RSTP mode, port is blocked.
Page 20
20
6641-22810
SFP Transceivers
The unit supports Westermo labelled transceivers only. See Westermo's modular transceivers datasheets 100 Mbit and 1 Gbit for supported SFP
transceivers for the RedFox series. See Transceiver User Guide "6100-0000" for transceiver handling instructions.
Deviations
With copper transceiver 1100-0148 the specified operating temperature on the RFI and RFIR series is 0 to 50ºC.
FRNT reconfiguration times can not be guaranteed with copper transceivers.
www.westermo.com – A Beijer Electronics Group Company
Modular Transceivers
RedFox, Lynx series and ODW-700 series
The Westermo range of Small Form-factor Pluggable (SFP) transceivers covers versions suitable for 10/100 Mbit/s and Gigabit applications. LC connectors are used as standard due their small size.
These transceivers have been verifi ed to meet the Westermo environmental specifi cation and can operate in a range
of different Westermo products in harsh industrial applications. The transceivers are coded to allow confi rmation that certifi ed versions have been installed.
Versions are available with different wave length including 1550 nm for extreme distances upto 120 km (74.5 mi) and 1310 nm version for both single (9/125) and multimode cables (50/125 and 62.5/125). In applications where only
a single fi bre core is available a Bi-Directional (BiDi) transceiver can be used.
…Wide choice to provide optimal solution
• 100 Mbit/s and 1000 Mbit/s versions
• Standard LC connector type
…Verifi ed to meet Westermo environmental specifi cations
• Temperature range –40 to +85°C (–40 to +185°F)
• Coded to guarantee quality
…Different transcivers for many solutions
• Multi mode fi bre up to 2 km (1.2 mi)
• Single mode fi bre up to 120 km (74.5 mi)
• Bi-directional fi bre transciversup to 120 km (74.5 mi)
• Copper transceivers, Gbit or 100 Mbit
EN 60825-1
Eye Safety: Class 1 laser product complies
Component Recognition
RXTX
Interfaces
How far can we get with transceivers
The different transceiver options are marked with an indicative range as a part of the transceiver description. This is the specifi ed distance when the transceiver is used
in 100 Mbit or Gbit applications.
For the ODW series the maximum distance (km) can be
calculated with the formula:
Power budget (dB) – signal loss (dB) / bre attenuation (db) per km.
Signal loss = splice attenuation x number of splices + con- nector attenuation x number of connectors + safety margin. Splice, connector and fi bre attenuation can be found on article
data sheets.
By calculating the maximum distance based on power budget a LC2 multimode transceiver can operate
up to 5 km (3.1 mi).
Transceivers_1508_EN_REV. A
www.westermo.com – A Beijer Electronics Group Company
Specifi cations Optical Transceivers
Dimensional / Temperature
Temperature specification
–40 to +85°C (–40 to +185°F) 0 to +70°C (32 to +158°F) GTX100, Copper
Article number
Transceiver Type
Link
speed
(Mbit/s)
Indicative
range (km)
Power
budget
(dB)
TX/RX
wavelength
(nm)
WeOS
ODW series
EX
approved
SFP, 100 Mbit
1100-0131 MLC2 Multimode 100 2 11 1310/1310 … … …
1100-0132 SLC20 Singlemode 100 20 19 1310/1310 … … …
1100-0133 SLC40 Singlemode 100 40 30 1310/1310 … … …
1100-0134 SLC80 Singlemode 100 80 30 1550/1550 … … …
1100-0140 SLC120 Singlemode 100 120 35 1550/1550 … … …
1100-0152 MLC2-BiDi-A Multimode 100 2 18 1310/1550 … … …
1100-0153 MLC2-BiDi-B Multimode 100 2 18 1550/1310 … … …
1100-0145 SLC20-BiDi-A Singlemode 100 20 18 1310/1550 … … …
1100-0146 SLC20-BiDi-B Singlemode 100 20 18 1550/1310 … … …
1100-0154 SLC40-BiDi-A Singlemode 100 40 26 1310/1550 … … –
1100-0155 SLC40-BiDi-B Singlemode 100 40 26 1550/1310 … … –
1100-0177 SLC80-BiDi-A Singlemode 100 80 29 1310/1550 … … –
1100-0178 SLC80-BiDi-B Singlemode 100 80 35 1550/1310 … … –
Copper, 100 Mbit
1100-0172 TX100 Copper 10/100 0.1 – – … – –
SFP, 1 Gbit
1100-0144 GMLC550-SX Multimode 1000 0.55 8.5 850/850 …* – …
1100-0147 GMLC2-SX+ Multimode 1000 2 10 1310/1310 …* – …
1100-0141 GSLC10-LX Singlemode 1000 10 10.5 1310/1310 …* – …
1100-0142 GSLC50-XD Singlemode 1000 50 20 1550/1550 …* – …
1100-0143 GSLCLC80-ZX Singlemode 1000 80 24 1550/1550 …* – …
1100-0171 GSLC110-EZX Singlemode 1000 120 30 1550/1550 …* – …
1100-0156 GSLC20-BiDi-A Singlemode 1000 20 15 1310/1490 …* – …
1100-0157 GSLC20-BiDi-B Singlemode 1000 20 15 1490/1310 …* – …
Copper, 1 Gbit
1100-0148 GTX100 Copper 1000 0.1 – – …* – …
DDM SFP, 100 Mbit
1100-0531 MLC2-DDM Multimode 100 2 11 1310/1310 … … …
1100-0532 SLC20-DDM Singlemode 100 20 17 1310/1310 … … …
1100-0533 SLC40-DDM Singlemode 100 40 30 1310/1310 … … …
1100-0573 SLC120-BiDi-B-DDM Singlemode 100 120 32 1550/1490 … … –
1100-0574 SLC120-BiDi-A-DDM Singlemode 100 120 32 1490/1550 … … –
DDM SFP, 1 Gbit
1100-0547 GMLC2-DDM Multimode 1000 2 10 1310/1310 …* – …
1100-0542 GSLC50-DDM Singlemode 1000 50 20 1550/1550 …* – …
1100-0558 GSLC20-BiDi-A-DDM Singlemode 1000 20 15 1310/1550 …* – –
1100-0559 GSLC20-BiDi-B-DDM Singlemode 1000 20 15 1550/1310 …* – –
1100-0567 GSLC40-BiDi-A-DDM Singlemode 1000 40 20 1310/1490 …* – –
1100-0568 GSLC40-BiDi-B-DDM Singlemode 1000 40 20 1490/1310 …* – –
1100-0566 GSLC60-BiDi-A-DDM Singlemode 1000 60 25 1310/1550 …* – –
1100-0569 GSLC60-BiDi-B-DDM Singlemode 1000 60 25 1550/1310 …* – –
* N.B. Can not be used in RFI-F8/F16 modules.
Transceivers_1508_EN_REV. A
ESD Protection
www.westermo.com
©
Westermo Teleindustri AB
User Guide
6100-0000
SFP
Transceivers
Page 21
21
6641-22810
Mounting
Wallmounting
The unit can also be wallmounted in all directions. Use maximum Ø6,4 mm or 1/4"screws.
Earth connection
For correct function, the ground connection on the unit needs to be properly connected to a solid ground. See the figure below.
This unit can either be rackmounted or wallmounted, see figures below.
Rackmounting
The unit can be mounted in all directions inside a 19" apparatus cabinet. Use M6x25 or 1/4"x1" screws.
<
_
+85°C (+185°F)
<
_
+85°C (+185°F)
Status-
Status+
Digital In-
Digital In+
Protective earth
Cooling
For mounting in 19" apparatus cabinet without forced ventilation, a minimal spacing of 1U according to IEC 60297 or 45 mm (1.75") above/below is recommended. With forced ventilation, no minimal spacing is required as long as the temperature of the rear cooling plates does not exceed +85ºC (+185ºF).
For wallmounting in an area without forced ventilation, a minimum spacing of 45 mm (1.75") above/below and 10 mm (0.4") left/right is recommended. For areas with forced ventilation, no minimal spacing is required as long as the temperature of the rear cooling plates does not exceed +85ºC (+185ºF).
Page 22
22
6641-22810
Getting Started
This product runs Westermo Operating System (WeOS) which provides several management tools that can be used for configuration of the unit.
• WeConfig
WeConfig is a Network configuration management tool (NCM) made for commissioning and maintenance of components in a network.
• Web
Configuration of the unit using the web browser.
• CLI Configuration of the unit via the Command Line Interface.
If the computer is located in the same subnet as the switch you can easily use a web browser to configure the unit. Within the web you can configure most of the available functions.
For advanced network settings and more diagnostic information, please use the CLI. Detailed documentation is available in the chapter The Command Line Management Tool in the WeOS management guide.
Factory default IP address: 192.168.2.200 (and DHCP client) Netmask: 255.255.255.0 Gateway: Disabled
Note! If you are not sure about the subnet – consult your network administrator.
Configuration
Configure the unit via Web browser
The unit can easily be configured via a Web browser. Open the link http://192.168.2.200 in your web browser, and you will be prompted with a Login screen, where the default settings for Username and Password are:
Username: admin Password: westermo
Once you have logged in, you can use the extensive integrated help function describing all configuration options. Two common task when configuring a new switch is to assign appropriate IP settings, and to change the password of the admin account. The password can be up to 64 characters long, and should consist of printable ASCII characters (ASCII 33-126); 'Space' is not a valid password character.
Page 23
23
6641-22810
Cable factory reset on RedFox Industrial Rack
It is possible to set the unit to factory default settings by using a standard (straight) Ethernet RJ-45 cable.
1. Power off the switch and disconnect all Ethernet cables (including copper and fibre).
2. Connect an Ethernet cable between Ethernet port 1 and Ethernet port 2. The ports need to be connected directly by an Ethernet cable, i.e., not via a hub or switch. Use a straight cable - not a cross-over cables - when connecting the ports.
3. Power on the unit.
4. Wait for the unit to start up. Control that the ON LED is flashing red. The ON LED flashing indicates that the unit is now ready to be reset to factory default. You now have the choice to go ahead with the factory reset, or to skip factory reset and boot as normal.
• Go ahead with factory reset: Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cable. The ON LED will stop flashing. This initiates the factory reset process, and the unit will restart with factory default settings. When the switch has booted up, the ON LED will show a green light, and is now ready to use.
• Note! Do not power off the unit while the factory reset process is in progress. Skip the factory reset: To skip the factory reset process, just wait for approximately 30 seconds (after the ON LED starts flashing RED) without unplugging the Ethernet cable. The switch will conduct a normal boot with the existing settings.
Referring documents
All needed documentation can be downloaded from the product webpage. Related software tools are available in the folder software tools under technical support on the Westermo website.
Type Description Document number
Management Guide Westermo OS management guide
6101-3201
Page 24
REV. J 6641-22810 2016-05 Westermo Teleindustri AB, Sweden
For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code
China sales.cn@westermo.com www.cn.westermo.com
France infos@westermo.fr www.westermo.fr
Germany info@westermo.de www.westermo.de
North America info@westermo.com www.westermo.com
Singapore sales@westermo.com.sg www.westermo.com