Wells RW-16 Installation Manual

ELECTRICAL
INSTALLATION INSTRUCTIONS
BUILT-IN DRAWER WARMERS
RW-16 (T, HD)
FIELD
WIRINGPHASEAMPSWATTSVOLTSMODEL
GAUGE
RW-16 RW-16 SINGLE 14 AWB Cu 90°C RW-16
RW-16HD, RWT-16/16HD MODELS HAVE THE SAME ELECTRICAL SPECIFICATIONS AS THE STANDARD UNITS
208 240 450 1.9
450120 338
3.8
1.6 SINGLE
14 AWB Cu 90°C
CUTOUT DETAILS PRODUCT DIMENSIONS
23
(584)
29 1/4
(743)
TEMP.
RATING
90°C14 AWB CuSINGLE
INCHES
(MM)
FIELD WIRE CONNECTION 6" PIGTAIL
5 5/8
(143)
21 1/2
(546)
14 3/8
(365)
REAR SUPPORT
9 7/8 (251)
28 1/8
(714)
FRONT PANEL CUT-OUT DIMENSIONS
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED BELOW UPON INSTALLATION:
TO FABRICATE:
1. Layout front panel cutout dimensions and cutout hole in counter front panel.
2. Position attaching flange (supplied) in hole cutout to determine screw hole location. Drill holes using #34 drill.
3. Attach flange to front panel using #6 screws provided.
4. Fabricate rails and rear support in locations shown. TO INSTALL:
1. For ease of installation, remove drawer from unit.
2. Slide unit through front panel opening until rear of unit engages rear support.
3. Remove control knob and control panel.
4. Install #8-32 speednuts on attaching flange, secure attaching flange to front panel, then secure unit to attaching flange using #8-32 flathead screws provided.
5. Connect service leads to the unit including ground wire.
6. Replace control panel and control knob.
7. Replace drawer.
RAILS FLUSH TO BOTTOM OF CUT-OUT
21 1/2
(546)
10 7/8
(276)
FROM OUTSIDES
23
OF RAILS
(584)
21 1/2
(546)
REAR SUPPORT
9 1/2
(241)
37119-1 REV (-)