Wells RCP-7500 Installation Manual

SPECIFICATIONS
VOLTS
HP
115
AMPS SINGLE PHASE
LRA
59
L1-NMFS
30 15.33/4
REFRIGERANT
DESIGN PRESSURE
TYPE QUANTITY LOWHIGH
54 OZR-404-A
500 174
POWER SUPPLY
NEMA 5-20P
INSTALLATION INSTRUCTIONS
REFRIGERATED COLD PAN
MODEL RCP-7500
CUTOUT DETAILS
AIR FLOW
72 3/4 (1848)
PRODUCT DIMENSIONS
25 7/8
(657)
(1880)
REMOVEABLE
1-PIECE
PAN RAIL
74
68 3/4 (1746)
66 3/4 (1695)
37
(940)
19 7/8
(505)
AIR FLOW
21 7/8
(556)
27 1/8
(689)
ELECTRONIC TEMPERATURE CONTROLLER
AIR FLOW
ADD
SUPPORTS
POWER SWITCH
25 3/8
(645)
FRONT VIEW
CONTROL SIDE
CLEARANCES
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE.
BACK0SIDE0BOTTOMNAFRONT
0
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED BELOW UPON INSTALLATION:
1. This unit may be installed in stainless steel, wood, Formica, or Corian tables and countertops.
2. This unit is shipped completely assembled and requires only a 30 AMP dedicated grounded outlet(NEMA 5-20R) and drain connection. Power cord and Power Switch should be accessible from the front of the unit.
3. When installing the unit it is essential to provide side openings twice the surface area of the condenser for adequate air circulation. Louvered grills with proper size may be placed in each opening.
TO INSTALL:
1. Lay out "cutout" dimensions on countertop or table.
2. Cut out hole and add stiffeners to support weight as shown. Countertop must be flat and level before installing cold pan.
3. Apply a generous bead of silicone sealant to underĀ­side of mounting flange before setting unit into cutout. Remove any excess sealant from top flange and countertop.
4. Connect 1 inch drain to drain pan or floor drain. Consult local codes for approved drain connections.
1"NPT DRAIN
ADD
SUPPORT
72 1/2 (1842)
WELLS/BLOOMFIELD * VERDI, NV
11 3/8
(289)
(76)
25 3/8
(645)
14
(356)
23
POWER SUPPLY
CORD
1
5/16
(8)
(25)
3
(584)
RIGHT SIDE VIEW
2 5/8
(67)
INCHES
(MM)
9 1/2 (241)
1" NPT DRAIN
CROSS-SECTION OF COLD PAN
022403 FCN12397 305895-5 REV (-)