SPECIFICATIONS
VOLTS
HP
1/4 28 OZR-134-A
115
AMPS SINGLE PHASE
LRA
38
L1-NMFS
15 5.5
REFRIGERANT
DESIGN PRESSURE
TYPE QUANTITY LOWHIGH
440 162
POWER
SUPPLY
CORD
NEMA 5-15P
INSTALLATION INSTRUCTIONS
REFRIGERATED COLD PAN
MODEL RCP-7200
ADD
SUPPORTS
CUTOUT DETAILS
31 1/2
(800)
ELECTRONIC
TEMPERATURE
CONTROLLER
CROSS SECTION
FRONT VIEW
CONTROL SIDE
AIR
FLOW
POWER
SWITCH
23
(584)
31 1/4
(794)
25 7/8
(657)
1"NPT DRAIN
AIR
FLOW
POWER
SUPPLY
CORD
27 1/8
(689)
PRODUCT DIMENSIONS
21 7/8
(556)
19 7/8
(505)
AIR
FLOW
25 1/2
(648)
27 1/2
(699)
32 3/4
(832)
19
(483)
RIGHT SIDE VIEW
REMOVEABLE
PAN RAIL
PLAN VIEW
26 1/8
(664)
1-PIECE
CLEARANCES
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE.
FRONT
BOTTOM
SIDE
BACK
0
0
0
NA
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:
1. This unit may be installed in stainless steel, wood, Formica,
or Corian tables and countertops.
2. This unit is shipped completely assembled and requires
only a 15 AMP dedicated grounded outlet (NEMA 5-15R) and
drain connection. Power cord and Power Switch should be
accessible from the front of the unit.
3. When installing the unit it is essential to provide
side openings twice the surface area of the condenser for
adequate air circulation. Louvered grills with proper size
may be placed in each opening.
TO INSTALL:
1. Lay out "cutout" dimensions on countertop or table.
2. Cut out hole and add stiffeners to support weight
as shown. Countertop must be flat and level before
installing cold pan.
3. Apply a generous bead of silicone sealant to underĀside of mounting flange before setting unit into cutout.
Remove any excess sealant from top flange and countertop.
4. Connect 1 inch drain to drain pan or floor drain.
Consult local codes for approved drain connections.
WELLS/BLOOMFIELD * VERDI, NV
11 3/8
(289)
(76)
INCHES
(MM)
1
5/16
(8)
(25)
2 5/8
(67)
9 1/2
(241)
3
1" NPT DRAIN
CROSS-SECTION OF COLD PAN
022403 FCN12397 305895-2 REV (-)