SPECIFICATIONS
VOLTS
HP
115
AMPS SINGLE PHASE
LRA
33
L1-NMFS
15 7.51/2
REFRIGERANT
DESIGN PRESSURE
TYPE QUANTITY LOWHIGH
32 OZR-404-A
500 174
PRODUCT DIMENSIONSCUTOUT DETAILS
POWER
SUPPLY
CORD
NEMA 5-15P
86
(2184)
INSTALLATION INSTRUCTIONS
REFRIGERATED COLD PAN
MODEL RCP-600
INCHES
(MM)
ADJUSTABLE
PRESSURE
SWITCH
POWER
SWITCH
23
(584)
AIR
FLOW
84 1/2
(2146)
ADD
SUPPORTS
84 1/4
(2140)
AIR
FLOW
1" NPT
DRAIN
60 1/8
(1527)
43
(1092)
ADD
SUPPORT
23 7/8
(606)
24 1/2
(622)
POWER
SUPPLY
CORD
82
(2083)
80 1/2
(2045)
19 7/8
(505)
19
(483)
AIR
FLOW
21 3/8
(542)
23 5/8
(600)
25 3/8
(643)
CLEARANCES
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE.
BACK0SIDE0BOTTOMNAFRONT
0
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:
1. This unit may be installed in stainless steel, wood, Formica,
or Corian tables and countertops.
2. This unit is shipped completely assembled and requires
only a 15 AMP dedicated grounded outlet (NEMA 5-15R) and
drain connection. Power cord and Power Switch should be
accessible from the front of the unit.
3. When installing the unit it is essential to provide
side openings twice the surface area of the condenser for
adequate air circulation. Louvered grills with proper size
may be placed in each opening.
TO INSTALL:
1. Lay out "cutout" dimensions on countertop or table.
2. Cut out hole and add stiffeners to support weight
as shown. Countertop must be flat and level before
installing cold pan.
3. Apply a generous bead of silicone sealant to underĀside of mounting flange before setting unit into cutout.
Remove any excess sealant from top flange and countertop.
4. Connect 1 inch drain to drain pan or floor drain.
Consult local codes for approved drain connections.
5/16
(8)
1
(25)
9 3/4
(248)
CENTERED TO THE PAN
WELLS/BLOOMFIELD * VERDI, NV
3/4
(19)
1" NPT DRAIN
CROSS-SECTION OF COLD PAN
2 11/16
(68)
8
(203)
022403 FCN12397 305894-6 REV (-)