CLEARANCE FROM COMBUSTIBLE SURFACES OR STRUCTURES
WARNING: Clearance from any surface or structure is 26 inches from the back and sides of
the burner station. Refer to “Typical Gas Supply Installation” before starting installation.
LOCATING YOUR SIDE BURNER
When determining a suitable location for your side burner installation, give attention to concerns such as exposure to
wind, proximity to traffic paths, and keeping any gas supply lines as short as possible. Never locate the Vieluxe
®
side
burner in a garage, breezeway, shed, under an unprotected overhang, or other enclosed area. Locate the burner station
and structure so there is enough room to safely evacuate the area in case of a fire.
Built-In Natural Gas Burner Station Installation Guide
Vieluxe®Countertop Dual Burner Station
(Model #: 37152)
Vieluxe
®
Slide-In Dual Burner Station
(Model #: 36152)
THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY.
WARNING: The structure, “island”, countertops, and adjacent work areas for the built-in
burner station installation must be built from non-combustable materials only.
NOTE: If you have questions on what materials are considered non-combustable, contact you
local building supplier or fire department.
61344 021304
26 inches Any Surface
Any Surface
26 inches
26 inches
Any Surface
Side Burner
2
BUILT-IN STRUCTURE CUTOUT DIMENSIONS
WARNING: All countertop finished surfaces must be constructed of a noncombustible material.
Countertop Burner Station
All dimensions are to finished surfaces.
Countertop
Burner
Station Tolerances
A28
3
⁄4"
B8
3
⁄4"
C22
1
⁄2"
+
1
⁄4
- 1⁄4
+ 1⁄4
- 1⁄4
+ 1⁄4
- 1⁄4
DIMENSIONS
COUNTERTOP CUTOUT DIMENSIONS
Slide-In Burner Station
SLIDE-IN CUTOUT DIMENSIONS
Slide-In
Burner
Station Tolerances
A28
3
⁄4"
B 36"
C22
1
⁄2"
+
1
⁄4
- 1⁄4
+ 1⁄4
- 1⁄4
+ 1⁄4
- 1⁄4
DIMENSIONS
All dimensions are to finished surfaces.
Slide-In
Burner
Station Tolerances
A4”
B7”
C2
1
⁄
2”
+
1
⁄16
- 1⁄16
+ 1⁄16
- 1⁄16
+ 1⁄
16
- 1⁄16
33
BUILT-IN GAS LINE LOCATIONS
Area should be kept clear of sharp, jagged, or extremely abrasive surfaces to avoid possible damage to gas supply lines.
Exercise caution when pulling gas lines through built-in structure.
Note: Leave an access in the "island" structure for gas supply and regulator service, not inside the grill
structure. Vieluxe®has a gas line and regulator access door available from your dealer or call Vieluxe®Customer
Service at 1-866-VIELUXE. (Vieluxe part number 36311).
A
C
B
Front View
Front of Burner Station Structure
Plan View
COUNTERTOP BURNER STATION
GAS LINE DIMENSIONS
DIMENSIONS
SLIDE-IN BURNER STATION
GAS LINE DIMENSIONS
Countertop
Burner
Station Tolerances
A4”
B7”
C2
1
⁄2”
+
1
⁄8
- 1⁄8
+ 1⁄8
- 1⁄8
+ 1⁄8
- 1⁄8
DIMENSIONS
Plan View
Front of Burner Station Structure
A
B
C
Front View