7
10 Fault codes
Status / Error message Possible cause Correction
A09 Fault, cabin temperature sensor
Cabin temperature sensor defective,
break/short-circuit in electrical circuit,
cabin temperature sensor not connec-
ted.
Please contact your authorised Webasto Marine
dealer.
A10 Malfunction, water temperature sen-
sor
Water temperature sensor defective or
break/short-circuit in electrical circuit.
BA11 Required cold water temperature not
yet reached
Air handler is only switched on when
the required cold water temperature is
reached.
No action required. The air handler starts up auto-
matically.
INIT Initialisation procedure or system blo-
cked.
Electrical wiring defective.
Power circuit interruption/short circuit.
Please contact your authorised Webasto Marine
dealer.
n/a No pc-board output
Fuse faulty or break/short-circuit in this
electrical circuit.
Pc-board damaged by high voltage
(RT1 blown)
n/a No or insufficient cooling or heating
capacity.
Poor air or water flow. Secure adequate air or water flow
Chiller unit not switched on.
Switch on the chiller unit and check whether the
cold water circuit reaches the required tempera-
ture for cooling or heating.
n/a Incorrect cabin/ambient temperature
or water temperature displayed.
Temperature sensor positioned incor-
rectly, subject to interference or display
values falsified.
Check whether the temperature sensor is subject
to direct fault sources such as direct sunlight or
devices radiating heat.
Please contact your authorised Webasto Marine
dealer.